Measuring Rate: Gas Volume, Mass Loss and Colour
A question to start
You cannot see molecules, and you cannot dip a ruler into a beaker to read "". So how do chemists actually follow a reaction as it happens and draw its rate curve?
The idea
We choose a property that changes as the reaction goes on and is easy to measure, and we record it at regular times. Three classic methods:
- Volume of gas given off, collected in a gas syringe (xi-lanh khí) or in an upturned measuring cylinder over water.
- Loss of mass as a gas escapes, read on a top-pan balance every few seconds.
- Colour or cloudiness: a coloured reactant fades, or a solid forms and the mixture goes cloudy (the "disappearing cross"). A colorimeter measures this as a number.
Each gives a quantity that is proportional to the amount reacted, so the shape of its graph is the shape of the rate curve.
| Quantity | Symbol | Unit | Measured with |
|---|---|---|---|
| volume of gas | mL | gas syringe, measuring cylinder | |
| mass of the flask | g | top-pan balance (0.01 g or 0.001 g) | |
| time | s | stopwatch | |
| time for a fixed change | s | stopwatch ("disappearing cross") |
The formulas
Average rate from a gas-volume or mass-loss table:
Gas volume to amount (at and 1 bar; Vietnamese textbooks also use at , 1 atm):
When we time how long a fixed amount of change takes (the cross disappears), a faster reaction takes less time, so
Gas volume
The reaction of marble chips (calcium carbonate) with hydrochloric acid gives carbon dioxide:
The gas pushes the syringe's plunger out, or pushes water down the upturned cylinder. A gas syringe is accurate to about ; collecting over water does not work for gases that dissolve well in water (ammonia, hydrogen chloride).
Mass loss
The flask stands on a balance. A loose cotton wool plug lets the out but stops acid spray escaping (which would also lose mass). The mass falls by exactly the mass of gas lost. This works well for a heavy gas like () but badly for hydrogen (): the change is too small to read.
Colour and cloudiness
Sodium thiosulfate reacts with hydrochloric acid to give a fine yellow precipitate of sulfur:
The flask stands on paper marked with a cross, and you time how long it takes for the cross to vanish when you look down through the mixture. Because this reaction gives off sulfur dioxide (an irritating gas), it is a school lab practical with your teacher, in a well-ventilated room, with small volumes and eye protection. A colorimeter does the same job more objectively, for example following the fading of a coloured reactant such as bromine water.
Worked examples
Example 1 (rate from gas-volume data). Given: of (excess acid) gave these volumes of :
| (s) | 0 | 30 | 60 | 90 | 120 | 150 | 180 | 210 | 240 | 270 |
|---|---|---|---|---|---|---|---|---|---|---|
| (mL) | 0 | 39 | 63 | 77 | 86 | 91 | 94 | 96 | 97 | 98 |
Find: the average rate in the first 30 s and between 120 and 150 s. Formula: . Solve: first 30 s: . From 120 to 150 s: . Answer: at first, only later. Check: the rate falls as the carbonate is used up; the graph flattens.
Example 2 (is the final volume right?). Given: of (), acid in excess, gas at , 1 bar. Find: the expected final volume of . Formula: ; ; 1 mol gives 1 mol . Solve: ; . Answer: about . Check: the readings level off at , just below , so the reaction is practically complete at 270 s.
Example 3 (initial rate from the tangent). Given: the tangent at on the graph rises in . Find: the initial rate in mL/s and in mol per second. Solve: ; . Answer: , i.e. of . Check: the initial rate is larger than the 0–30 s average (), since the rate is already falling during those 30 s.
Example 4 (mass loss). Given: the same reaction on a balance: at , at . Find: the average rate of mass loss and the amount of given off in that minute. Solve: ; ; . Answer: ; of . Check: the whole would weigh ; after 60 s about has gone, matching of in Example 1.
Example 5 (disappearing cross, rate ). Given: with thiosulfate at the cross vanishes in ; at it takes . Find: the relative rates. Solve: and : halving the concentration halves the rate. Answer: the rate is proportional to the thiosulfate concentration. Check: the same amount of sulfur is needed to hide the cross each time, so a longer time really means a slower reaction.
Try it: a balloon gas collector (fair test)
You need: two identical small plastic bottles, two balloons, a funnel, vinegar, baking soda, a measuring spoon, a measuring jug, a tape measure or string, a timer, eye protection.
- Put of vinegar in each bottle.
- Using the funnel, put 1 level teaspoon of baking soda into one balloon and 2 level teaspoons into the other.
- Stretch each balloon over a bottle neck, letting it hang to the side so no powder falls in yet.
- Lift both balloons at the same moment so the powder drops in. Every 10 s, measure the balloon's widest circumference with the string.
- Keep everything else the same: the same vinegar, the same temperature, the same bottles (a fair test). Plot circumference against time for both.
What you should see: both balloons grow fast at first and then stop; the 2-teaspoon balloon ends bigger. The gas is carbon dioxide: . Pour the liquids down the sink afterwards. Do not reuse the balloons for blowing up by mouth.
Common mistakes
- Collecting a soluble gas over water. Ammonia or hydrogen chloride dissolve and the volume reads far too low.
- Sealing the flask on the balance. With a bung, no gas escapes and the mass does not change; the cotton wool must be loose.
- Forgetting that rate is . A longer time to the end point means a slower reaction.
- Starting the clock late. Add the solid and start timing at the same moment; for gas methods, put the bung in immediately.
Practice
- Using the table in Example 1, find the average rate between 60 and 120 s.
Answer
.
- of magnesium ribbon reacts with excess hydrochloric acid: . What final volume of hydrogen is collected at and 1 bar? Why would mass loss be a poor method here?
Answer
; . The hydrogen weighs only , too small a change to follow well on a balance.
- In a cross experiment, the cross vanishes in at and in at . By what factor has the rate changed?
Answer
Rate : . The rate doubles.
Test yourself
Which method would be best to follow the rate of ?
- Collect the hydrogen in a gas syringe and read the volume every 10 s
- Weigh the flask on a balance every 10 s
- Time how long a cross takes to disappear
- Measure the colour with a colorimeter
Why is a loose cotton wool plug used in the mass-loss method?
- To keep the carbon dioxide inside the flask
- To stop air getting in
- To let the gas escape while stopping acid spray from leaving
- To slow the reaction down
In a disappearing-cross experiment, the cross vanishes after 40 s in run A and after 80 s in run B. Compared with B, the rate in A is
- half as large
- the same
- twice as large
- four times as large
of reacts completely with excess acid at , 1 bar. What volume of forms?