TExcelTAD

SOC Roles, Tiers and Shifts

A SOC that receives 900 alerts a day and has three analysts has already decided, whether it knows it or not, that most alerts will get a glance and nothing more. How work is divided between people, how it moves between them and how many people are on shift at 03:00 decide what the SOC can actually catch. This lesson describes the classic roles, the tiered model and its critics, and sizes a team from alert volume with a small capacity model.

The roles

Role Main question Typical work
L1 analyst (triage) Is this alert real, and does it need someone else? Works the alert queue, follows playbooks, enriches with context, closes false positives with a reason, escalates the rest
L2 analyst (investigation) What happened, how far did it go? Deep investigation across sources, scoping (which hosts, which accounts), first containment steps, writes the case
L3 / incident responder How do we stop it and recover? Leads incidents, forensics, containment and eradication with IT, coordinates with legal and management; often the DFIR team
Detection engineer What should alert, and does it work? Writes, tests and tunes detection rules as code, owns coverage and false-positive rates
Threat-intelligence analyst Who is likely to attack us, and how? Turns reports and feeds into priorities, indicators and hunting hypotheses
Threat hunter What are the rules missing? Hypothesis-driven searches in the data; each finding becomes a detection
SOC engineer / platform Is the data flowing and the SIEM healthy? Log pipelines, parsers, agents, retention, SIEM performance
SOC manager / lead Are we getting better? Staffing, metrics, priorities, reporting to the CISO

In small teams one person holds several roles; in large ones each role is a team. The roles matter more than the titles: someone must own the rules, someone the data pipeline, and someone the decision to wake the incident commander.

Tiers and escalation

alerts100 % L1 triagecloses ~85 % 15 % L2 investigationcloses ~80 % 3 % L3 / incidentresponse detection engineering (tuning) illustrative escalation rates; each tier's closure reasons feed tuning

The tiered model is easy to staff and to train: L1 needs playbooks, not years of experience. Its known weaknesses:

  • Context is lost at every handoff. An L1 who escalates with "suspicious PowerShell, see alert" forces L2 to redo the work. Escalations need a summary: what was seen, what was checked, what is still unknown.
  • L1 burns out. Closing the same false positive fifty times a day is the fastest route to people leaving. The fix is upstream: tune the rule (see Alert Fatigue).
  • Learning stalls. If L1 never sees how an incident ends, it never learns which "harmless" alerts mattered.

Many SOCs now run tierless or "pod" models: small teams that own an alert from triage to closure, with automation (SOAR playbooks) doing the enrichment that L1 used to do by hand. Whichever model you use, write down the escalation criteria (what must go to L2 or incident response, and within how long) so that the decision does not depend on who is on shift.

Shifts and coverage

Attackers like weekends and holidays because fewer people watch. Covering 24 × 7 takes more people than it seems: a week has 168 hours, a full-time analyst works about 40 of them, minus leave, training and sickness. Common patterns are three 8-hour shifts, two 12-hour shifts (fewer handovers, more fatigue), or follow-the-sun with teams in three time zones each working their daytime. Small organisations often buy night and weekend coverage from a managed security service provider (MSSP or MDR) and keep daytime in house.

Sizing a team from the alert queue

Staffing starts from work, not headcount: how many alerts arrive, how long each takes, and how much of an analyst's shift is actually spent on alerts.

python · try it yourself
alerts_per_day = 900
minutes = {"close as false positive": 6, "close after enrichment": 15, "escalate to L2": 30}
mix = {"close as false positive": 0.70, "close after enrichment": 0.15, "escalate to L2": 0.15}

work = sum(alerts_per_day * mix[k] * minutes[k] for k in mix) / 60
print(f"L1 work: {work:.0f} analyst-hours per day")

productive = 8 * 0.65       # an 8-hour shift, 65 % on alerts (the rest: handover, meetings, breaks, training)
print(f"analyst shifts per day: {work / productive:.1f}, about {work / productive / 3:.1f} analysts per 8-hour slot")

# 24x7 coverage: every shift is 8 paid hours; a person works about 1650 hours a year after leave, sickness, training
fte = work / productive * 8 * 365 / 1650
print(f"full-time L1 analysts for 24x7: {fte:.1f}")

for fp_cut in (0.0, 0.3, 0.5):   # tuning removes part of the false positives
    m = dict(mix); m["close as false positive"] *= 1 - fp_cut
    w = sum(alerts_per_day * m[k] * minutes[k] for k in m) / 60
    print(f"cut false positives by {fp_cut:.0%}: {w:5.1f} h/day, {w / productive * 8 * 365 / 1650:4.1f} FTE")
L1 work: 164 analyst-hours per day
analyst shifts per day: 31.6, about 10.5 analysts per 8-hour slot
full-time L1 analysts for 24x7: 55.9
cut false positives by 0%: 164.2 h/day, 55.9 FTE
cut false positives by 30%: 145.3 h/day, 49.5 FTE
cut false positives by 50%: 132.8 h/day, 45.2 FTE

900 alerts a day is 164 hours of triage, about 10 to 11 analysts on every 8-hour slot and 56 full-time people once nights, weekends and leave are counted. Few SOCs have that, which is why most alerts in an untuned SOC get a glance. The last lines show the lesson SOC leads repeat most often: tuning is cheaper than hiring. Removing half of the false positives saves about 31 hours of work a day, the equivalent of 10.7 full-time analysts, and the remaining alerts are more likely to be read with care.

How this goes wrong, and how it is fixed

Symptom Usual cause Fix
Escalations bounce back from L2 No escalation criteria, no summary Written criteria; an escalation template (seen / checked / unknown)
Night shift closes everything Fatigue, no second pair of eyes Pair or follow-the-sun; review a sample of closures every morning
Same false positive daily Closure reasons not fed back Each closure has a reason code; detection engineering reviews the top codes weekly
Nobody owns a rule Rules added ad hoc Every rule has an owner in its metadata (Detection as Code)

Pitfalls

  • Counting alerts closed as productivity. It rewards fast, shallow closing. Measure quality: sampled reviews, missed detections found later.
  • Making L1 the only path to incident response. A user calling "my screen says my files are encrypted" must reach the incident lead in minutes, not wait in the queue.
  • Hiring hunters before the data is good. Hunting on incomplete logs finds nothing; platform work comes first.

Practice

1. A SOC gets 400 alerts per day: 80 % close as false positives in 5 minutes, 20 % need 25 minutes. With 65 % productive time on 8-hour shifts, how many analyst shifts per day are needed?

Work = 400 × (0.8 × 5 + 0.2 × 25) / 60 = 400 × 9 / 60 = 60 hours. Productive hours per shift = 5.2, so 60 / 5.2 ≈ 11.5 shifts per day, about four analysts per 8-hour slot around the clock.

2. Write three escalation criteria that must take an alert straight to incident response, whatever the tier.

For example: (1) confirmed execution of malware or ransomware behaviour on any host; (2) any use of a domain-admin or other tier-0 account from an unexpected host; (3) evidence of data leaving to an unknown destination above a set volume. Each with a time limit (e.g. page the incident lead within 15 minutes).

3. Why do many teams move from tiers to pods with automation?

Handoffs lose context and slow response, L1 work is repetitive and causes burnout, and enrichment that L1 did by hand (look up the host owner, the user's department, the IP's reputation) is easy to automate. A pod that owns alerts end to end learns from outcomes.

Test yourself

Which role owns writing, testing and tuning detection rules?

  1. L1 analyst
  2. Detection engineer
  3. SOC manager
  4. Threat-intelligence analyst

In the capacity model, what did cutting false positives by half do?

  1. Nothing, because false positives are fast to close
  2. It reduced the analyst hours and full-time staff needed substantially
  3. It increased the work
  4. It removed all escalations

What should an escalation from L1 to L2 contain?

  1. Only the alert ID
  2. What was seen, what was already checked and what is still unknown
  3. The analyst's opinion of the rule author
  4. Nothing; L2 starts from scratch

Why does 24 × 7 coverage need far more than three people?

  1. Analysts can only work at night
  2. A week has 168 hours, a person works about 40, minus leave, training and sickness
  3. SIEMs require five users