Half-Wave, Full-Wave and Bridge Rectifiers
Almost every mains-powered device, and many battery chargers and motor drives, starts by turning AC into DC. The first step is a rectifier: diodes that let current through on one polarity, or steer both polarities into the same direction. Three circuits cover nearly every case. This lesson compares their output voltage, the stress on the diodes and how they use the transformer, with a peak, source as the running example.
Safety note. In a real supply the AC comes from a transformer whose primary is on the mains. Mains wiring is outside the scope of this course: the transformer circuits here are taught by calculation and simulation only. The bench version below uses a function generator instead.
Three rectifiers
- Half-wave: one diode in series with the load. It conducts on the positive half cycles only; the load sees nothing on the negative ones.
- Full-wave, centre-tapped: a transformer secondary with a centre tap (grounded) and two diodes, one at each end. Each half of the winding drives the load on alternate half cycles.
- Bridge: four diodes and a plain secondary (the figure). On each half cycle two diodes conduct, in series with the load, and steer the current through the load in the same direction.
Average, rms and diode drops
With ideal diodes and a peak input , the output averages and rms values are
The average is what a DC meter reads and what charges a battery; the rms sets the heating in a resistive load. Real diodes take a forward drop out of each conducting path: one drop for the half-wave and centre-tap circuits, two for the bridge. The output peak becomes or , and the diodes stay off near the zero crossings, until the input exceeds the drop. With the two drops of a bridge cost about 12 % of the peak; at they would cost almost half, which is why low-voltage rectifiers use Schottky diodes or MOSFET "synchronous" rectifiers (Zener and Schottky Diodes).
Peak inverse voltage and transformer use
Each diode must also block when it is off. The largest reverse voltage it sees is the peak inverse voltage (PIV):
| Circuit | Diodes | Drops in path | PIV per diode (ideal) | Ripple frequency |
|---|---|---|---|---|
| half-wave | 1 | 1 | ( with a reservoir capacitor) | |
| centre-tap full-wave | 2 | 1 | ||
| bridge | 4 | 2 |
The centre-tap circuit uses half of its secondary at a time, so it needs twice the winding for the same output, and its diodes see twice the PIV; in exchange there is only one drop. The bridge uses the whole secondary all the time, which is why it is the default above a few volts. The half-wave rectifier draws current from the transformer in one direction only: the DC component magnetises the core, which is acceptable only at low power. Choose diodes with a reverse voltage rating of at least 1.5 to 2 times the PIV, to cover line surges.
Worked example
Given: a bridge rectifier fed with , , driving ; take per diode.
Find: the output peak, an estimate of the average, and the PIV.
Solve:
Check: the quick estimate assumes a shifted sine; the true clipped wave averages a little less, because the diodes are off for a while near each zero crossing. Python gives the exact value for constant drops: , so . The PIV of the off diode is the input minus the drop of the conducting diode beside it.
In Python
import numpy as np
VP, VD = 12.0, 0.7 # peak input, drop per conducting diode
t = np.linspace(0, 1, 200001)[:-1] # one period, normalised
v = VP * np.sin(2 * np.pi * t)
cases = {
"half-wave, 1 drop": np.maximum(v - VD, 0),
"centre-tap, 1 drop": np.maximum(np.abs(v) - VD, 0),
"bridge, 2 drops": np.maximum(np.abs(v) - 2 * VD, 0),
}
print("ideal: half-wave avg = Vp/pi = %.3f V, full-wave avg = 2Vp/pi = %.3f V" % (VP / np.pi, 2 * VP / np.pi))
print(f"{'circuit':20s} {'peak':>6s} {'avg':>6s} {'rms':>6s} conducts")
for name, out in cases.items():
on = np.mean(out > 0) * 100
print(f"{name:20s} {out.max():6.2f} {out.mean():6.3f} {np.sqrt(np.mean(out**2)):6.3f} {on:5.1f} % of the time")ideal: half-wave avg = Vp/pi = 3.820 V, full-wave avg = 2Vp/pi = 7.639 V
circuit peak avg rms conducts
half-wave, 1 drop 11.30 3.476 5.558 48.1 % of the time
centre-tap, 1 drop 11.30 6.952 7.861 96.3 % of the time
bridge, 2 drops 10.60 6.291 7.247 92.6 % of the time
Cross-check with SPICE: the bridge
The source floats (as a transformer secondary does), so a resistor gives node b a DC path to ground. DREC is the course's 1 A rectifier model. The reverse voltage of D2 is .
cat > bridge.cir <<'EOF'
* bridge rectifier: 12 V peak, 50 Hz (a transformer secondary, simulated), 1 k load
.model DREC D(Is=15n N=1.9 Rs=0.04 Cjo=40p BV=100 IBV=10u)
V1 a b SIN(0 12 50)
RB b 0 10meg
D1 a p DREC
D2 b p DREC
D3 0 a DREC
D4 0 b DREC
RL p 0 1k
.control
tran 20u 60m
meas tran vpk max v(p) from=20m to=60m
meas tran vavg avg v(p) from=20m to=60m
meas tran vrms rms v(p) from=20m to=60m
let vrev = v(p) - v(b)
meas tran piv max vrev from=20m to=60m
.endc
.end
EOF
ngspice -b bridge.cir 2>&1 | grep -E '^(vpk|vavg|vrms|piv)'vpk = 1.067468e+01 at= 4.500560e-02
vavg = 6.424029e+00 from= 2.000000e-02 to= 6.000000e-02
vrms = 7.33802e+00 from= 2.00000e-02 to= 6.00000e-02
piv = 1.133733e+01 at= 4.500560e-02
SPICE's average () is 2 % above the constant-drop estimate because at only peak each DREC drops about , not , and conducts a little earlier. The peak and the PIV () occur at the crest of the input, into the run.
Guided lab: a half-wave rectifier from a function generator
Hand calculation. A generator set to peak (20 V peak-to-peak into a high-impedance load), a small-signal diode and : output peak about , average about (a bit less, from the dead zone).
Simulation. Change the SPICE deck to one diode and a load, or the Python VP and VD.
What you would measure. Most generators have a output and a peak-to-peak limit into an open circuit; with a load the loss in is 1 %. Scope channel 1 on the generator output, channel 2 on the load, both DC-coupled, shared ground. Expect flat zero on the negative half cycles, a peak about below the input's, and a DC meter reading of to (meters average differently at ; use or the scope's mean measurement). A full-wave bridge cannot be measured this way with a grounded generator and a grounded scope: the bridge's input and output share no common ground, so the scope's ground clip would short a diode. Use the simulation for the bridge.
Hazards and safe setup. Signal levels only; never feed a rectifier experiment from a mains transformer or a mains socket. The generator's output protection survives a short, but check the load before switching on.
Pitfalls
- Forgetting the second drop in a bridge. At low voltages it is a large loss.
- Grounding both sides of a bridge. A scope ground on the AC side and another on the DC side short-circuits one diode.
- Sizing diodes on the average current only. With a reservoir capacitor the diodes carry short, tall current pulses (The Reservoir Capacitor).
- Using a DC meter on pulsating DC and calling it the "voltage". It reads the average; the peak and rms differ.
Practice
- A centre-tapped transformer gives peak on each half. With , what is the output peak and the PIV?
- Which circuit gives the most DC output from a given total secondary winding, and why?
- For an ideal half-wave rectifier, show that .
Answer
- Output peak ; the off diode sees its half's plus the output, about .
- The bridge: it uses the full winding on both half cycles, while the centre-tap circuit uses only half of it at a time.
- , so .
Test yourself
An ideal full-wave rectifier fed with has an average output of…
How many diode drops are in the conducting path of a bridge rectifier?
- 0
- 1
- 2
- 4
The peak inverse voltage on each diode of a centre-tap full-wave rectifier (ideal diodes, peak per half) is…
The ripple of a full-wave rectifier on mains is at…