TExcelTAD

Transformers

A question to start

A laptop charger plugs into 230 V230\ \text{V}, but the laptop gets 20 V20\ \text{V}. A power station's generator gives about 20 000 V20\,000\ \text{V}, yet the lines across the country carry up to 500 000 V500\,000\ \text{V}. Which device changes the voltage, and why does it only work with AC?

The idea

A transformer (máy biến áp) is two coils wound on one closed iron core. The primary coil (cuộn sơ cấp), N1N_1 turns, is connected to the AC supply; the secondary coil (cuộn thứ cấp), N2N_2 turns, to the load.

  1. The alternating current in the primary makes an alternating flux in the core.
  2. The iron guides almost all of that flux through the secondary too.
  3. The changing flux induces an emf in every turn of both coils, the same emf per turn (Faraday).

So the voltages are in the ratio of the turns. A steady DC current makes a steady flux and induces nothing: transformers need AC.

U1U2=N1N2\frac{U_1}{U_2} = \frac{N_1}{N_2}

An ideal transformer wastes no energy, so the power in equals the power out:

U1I1=U2I2⇒I1I2=U2U1=N2N1U_1 I_1 = U_2 I_2 \qquad\Rightarrow\qquad \frac{I_1}{I_2} = \frac{U_2}{U_1} = \frac{N_2}{N_1}
Quantity Symbol Unit
turns on the primary, secondary N1N_1, N2N_2 none
rms voltages U1U_1, U2U_2 V\text{V}
rms currents I1I_1, I2I_2 A\text{A}
  • Step-up (N2>N1N_2 > N_1): higher voltage, smaller current.
  • Step-down (N2<N1N_2 < N_1): lower voltage, larger current.

A transformer can't create energy: what it gives in voltage it takes back in current. Real transformers are 9595 to 99%99\% efficient. The small losses come from the coils' resistance, from eddy currents in the core (kept small by building it from thin, insulated iron sheets) and from magnetising the iron back and forth.

AC in, U1load primary N1secondary N2iron core

Worked examples

Example 1 (step-down). A transformer turns 230 V230\ \text{V} into 12 V12\ \text{V}. Its primary has 11501150 turns. The load takes 24 W24\ \text{W}. Assuming it is ideal, find N2N_2, the secondary current and the primary current.

  • Given: U1=230 VU_1 = 230\ \text{V}, U2=12 VU_2 = 12\ \text{V}, N1=1150N_1 = 1150, P=24 WP = 24\ \text{W}.
  • Find: N2N_2, I2I_2, I1I_1.
  • Formula: N2=N1U2U1N_2 = N_1\frac{U_2}{U_1}, I2=PU2I_2 = \frac{P}{U_2}, I1=PU1I_1 = \frac{P}{U_1}.
  • Solve: N2=1150×12 V230 V=60N_2 = 1150 \times \frac{12\ \text{V}}{230\ \text{V}} = 60; I2=24 W12 V=2.0 AI_2 = \frac{24\ \text{W}}{12\ \text{V}} = 2.0\ \text{A}; I1=24 W230 V=0.10 AI_1 = \frac{24\ \text{W}}{230\ \text{V}} = 0.10\ \text{A}.
  • Answer: N2=60N_2 = 60 turns, I2=2.0 AI_2 = 2.0\ \text{A}, I1=0.10 AI_1 = 0.10\ \text{A}.
  • Check: the voltage fell by a factor 19.219.2, the current rose by the same factor: 0.104×19.2=2.0 A0.104 \times 19.2 = 2.0\ \text{A}.

Example 2 (step-up). A power station transformer has 200200 primary turns and steps 11 kV11\ \text{kV} up to 220 kV220\ \text{kV}. How many secondary turns does it need?

  • Given: U1=11 kVU_1 = 11\ \text{kV}, U2=220 kVU_2 = 220\ \text{kV}, N1=200N_1 = 200.
  • Find: N2N_2.
  • Formula: N2N1=U2U1\frac{N_2}{N_1} = \frac{U_2}{U_1}.
  • Solve: N2=200×220 kV11 kV=4000N_2 = 200 \times \frac{220\ \text{kV}}{11\ \text{kV}} = 4000.
  • Answer: N2=4000N_2 = 4000 turns.
  • Check: voltage ×20\times 20, so turns ×20\times 20, and the current in the line is 2020 times smaller than in the generator.

Try it: induction between two coils (battery only)

You need: a large iron bolt or nail, two lengths of thin insulated wire, a 4.5 V4.5\ \text{V} battery, a torch lamp in a holder, a multimeter on mV\text{mV} (or a centre-zero meter).

  1. Wind about 5050 turns of one wire on the bolt (primary) and 100100 turns of the other on top of it (secondary). Connect the secondary to the meter.
  2. Connect the primary to the battery through the lamp, then disconnect it. Watch the meter each time.

What you should see: a short kick when you connect, a kick the other way when you disconnect, and nothing while the current is steady. A battery gives a steady flux, so a transformer on DC only "works" at the moments of switching. That is why the mains is AC. Never connect a home-made coil to the mains.

Common mistakes

  • "A step-up transformer gives more power." It gives more voltage and less current; power out ≤\le power in.
  • Turning the ratio upside down. U1U2=N1N2\frac{U_1}{U_2} = \frac{N_1}{N_2} but I1I2=N2N1\frac{I_1}{I_2} = \frac{N_2}{N_1}.
  • Expecting a transformer to work on DC.

Practice

  1. A transformer has N1=500N_1 = 500 and N2=25N_2 = 25. It is connected to 230 V230\ \text{V}. Find U2U_2. Is it step-up or step-down?
Answer

U2=230×25500=11.5 VU_2 = 230 \times \frac{25}{500} = 11.5\ \text{V}: step-down.

  1. A real transformer takes 100 W100\ \text{W} from the mains and supplies 12 V12\ \text{V}, 7.9 A7.9\ \text{A} to a lamp. Find its efficiency.
Answer

Pout=12×7.9=94.8 WP_{out} = 12 \times 7.9 = 94.8\ \text{W}; η=94.8100=95%\eta = \frac{94.8}{100} = 95\%.

  1. An ideal transformer steps 230 V230\ \text{V} up to 4600 V4600\ \text{V}. The secondary current is 0.050 A0.050\ \text{A}. Find the primary current.
Answer

I1=I2U2U1=0.050×4600230=1.0 AI_1 = I_2\frac{U_2}{U_1} = 0.050 \times \frac{4600}{230} = 1.0\ \text{A}.

Test yourself

An ideal transformer has N1=1150N_1 = 1150, N2=60N_2 = 60 and U1=230 VU_1 = 230\ \text{V}. The secondary voltage is...

  1. 12 V12\ \text{V}
  2. 60 V60\ \text{V}
  3. 4400 V4400\ \text{V}
  4. 19 V19\ \text{V}

Why does a transformer not work with a steady DC supply?

  1. DC is too weak
  2. A steady current makes a steady flux, which induces no emf
  3. Iron blocks DC
  4. The coils would melt

In an ideal step-up transformer, the secondary current compared with the primary current is...

  1. larger
  2. the same
  3. smaller
  4. zero

Why is a transformer core made of thin insulated iron sheets?

  1. To make it lighter
  2. To reduce eddy currents
  3. To increase the voltage
  4. To cool the coils with air