TExcelTAD
Home › Lab Skills: Safety, Glassware, Solutions & Titration › Glassware and What Each Piece Is For

Glassware and What Each Piece Is For

A question to start

A beaker has lines marked 5050 and 100 mL100\ \text{mL}. A volumetric flask has one line. A burette has fifty. Which one would you trust to measure exactly 25 mL25\ \text{mL}? And why does a chemist own all three?

The idea: holding is not measuring

Laboratory glassware does two different jobs: holding and mixing, or measuring a volume. The pieces made for measuring differ in how precise (chính xác) they are, and in whether they measure the volume they contain or the volume they deliver (pour out).

501002040608010001020304050beaker100 mLhold, mix, heat+-5 %rough marksconical flask250 mLswirl, titrateno scalefor measuringmeasuringcylinder 100 mLany volume+-0.5 mLhalf a divisionbulb pipette25.00 mLfixed volume+-0.06 mLprinted on itburette50.00 mLvolume run out+-0.05 mLper readingvolumetricflask 250.0 mLone exact volume+-0.3 mLprinted on it
Glassware Vietnamese Job Typical uncertainty (Class B, school glassware)
beaker cốc thủy tinh hold, mix, heat, pour; the marks are only a rough guide about ±5%\pm 5\%
conical flask (Erlenmeyer) bình tam giác swirl without spilling; titrations; the marks are rough not for measuring
measuring cylinder ống đong measure any volume quickly 100 mL100\ \text{mL} cylinder: ±0.5 mL\pm 0.5\ \text{mL}; 10 mL10\ \text{mL}: ±0.1 mL\pm 0.1\ \text{mL}
bulb (volumetric) pipette pipet bầu deliver one exact volume 25.00 mL25.00\ \text{mL} pipette: ±0.06 mL\pm 0.06\ \text{mL}
graduated pipette pipet chia vạch deliver small chosen volumes 10 mL10\ \text{mL}: ±0.1 mL\pm 0.1\ \text{mL}
burette buret deliver any volume up to 50 mL50\ \text{mL}, read to 0.05 mL0.05\ \text{mL} ±0.05 mL\pm 0.05\ \text{mL} per reading
volumetric flask bình định mức contain one exact volume, to make standard solutions 250 mL250\ \text{mL}: ±0.3 mL\pm 0.3\ \text{mL}; 100 mL100\ \text{mL}: ±0.2 mL\pm 0.2\ \text{mL}

Two kinds of number appear in that last column:

  • A reading uncertainty comes from the scale: half the smallest division for a scale you read by eye. A 100 mL100\ \text{mL} cylinder with 1 mL1\ \text{mL} divisions reads to ±0.5 mL\pm 0.5\ \text{mL}, a burette with 0.1 mL0.1\ \text{mL} divisions to ±0.05 mL\pm 0.05\ \text{mL}.
  • A tolerance is printed on glassware with a single mark (pipettes, volumetric flasks): the maker promises the volume is within it, for example "25 mL±0.06 mL25\ \text{mL} \pm 0.06\ \text{mL}, Class B, Ex 20 ∘C20\,^\circ\text{C}". Class A glassware is made to about half the tolerance of Class B. Ex (or TD) means calibrated to deliver; In (or TC) means calibrated to contain. Always use the number printed on your glassware.

Which piece, when?

  • An approximate volume (dissolving a solid, a reaction in a test tube): beaker or measuring cylinder.
  • One exact volume to be transferred, as in a titration: pipette.
  • An unknown volume that must be measured exactly as it is added: burette.
  • A solution made up to an exact total volume: volumetric flask.
  • The smaller the volume, the smaller the cylinder: a 10 mL10\ \text{mL} cylinder for 7.5 mL7.5\ \text{mL}, not a 100 mL100\ \text{mL} one.

Other everyday pieces

Test tube (ống nghiệm) and wider boiling tube for small reactions; dropping pipette (ống nhỏ giọt) for a few drops, not for measuring; filter funnel (phễu); evaporating dish (bát sứ) and crucible (chén nung), porcelain, for strong heating; watch glass (mặt kính đồng hồ) to cover a beaker or hold a small solid; gas syringe (xi lanh khí) to measure a volume of gas, usually 100 mL100\ \text{mL} marked every 1 mL1\ \text{mL}.

Clean and rinse correctly

Glassware Rinse last with Why
burette and pipette a little of the solution they will hold water left inside would dilute that solution
volumetric flask distilled water water is added up to the mark anyway
conical flask for a titration distilled water; it may stay wet the number of moles put in by the pipette does not change if water is present

Worked examples

Example 1: cylinder size. Find the percentage uncertainty of measuring 7.5 mL7.5\ \text{mL} of water with a 10 mL10\ \text{mL} cylinder (±0.1 mL\pm 0.1\ \text{mL}) and with a 100 mL100\ \text{mL} cylinder (±0.5 mL\pm 0.5\ \text{mL}).

  • Given: V=7.5 mLV = 7.5\ \text{mL}; ΔV=0.1 mL\Delta V = 0.1\ \text{mL} or 0.5 mL0.5\ \text{mL}.
  • Find: the percentage uncertainty of each.
  • Formula: percentage uncertainty =ΔVV×100%= \dfrac{\Delta V}{V} \times 100\%.
  • Solve: 0.17.5×100%=1.3%\dfrac{0.1}{7.5} \times 100\% = 1.3\%; 0.57.5×100%=6.7%\dfrac{0.5}{7.5} \times 100\% = 6.7\%.
  • Answer: 1.3%1.3\% with the small cylinder, 6.7%6.7\% with the large one.
  • Check: the big cylinder is five times worse. Always use the smallest cylinder that holds the volume.

Example 2: choose the glassware. For each task, choose and explain. (a) Add about 20 mL20\ \text{mL} of acid to marble chips. (b) Put exactly 25.00 mL25.00\ \text{mL} of a solution into a conical flask. (c) Measure how much alkali is needed to neutralise it. (d) Make exactly 250.0 mL250.0\ \text{mL} of a solution.

  • Answer: (a) measuring cylinder, or even a beaker: the amount need not be exact. (b) 25.00 mL25.00\ \text{mL} bulb pipette. (c) burette. (d) 250.0 mL250.0\ \text{mL} volumetric flask.
  • Check: only (b), (c) and (d) need two decimal places, so only they need precision glassware.

Example 3: writing the reading. Write each volume with the right number of decimal places: (a) 25 mL25\ \text{mL} from a 25 mL25\ \text{mL} pipette; (b) 36 mL36\ \text{mL} read on a 100 mL100\ \text{mL} cylinder with 1 mL1\ \text{mL} divisions; (c) a burette reading of 21.7 mL21.7\ \text{mL} exactly on a line.

  • Answer: (a) 25.00 mL25.00\ \text{mL} (±0.06\pm 0.06); (b) 36.0 mL36.0\ \text{mL} (±0.5\pm 0.5, the reading could also end in .5.5); (c) 21.70 mL21.70\ \text{mL} (±0.05\pm 0.05).
  • Check: the last digit written is the one the uncertainty affects. More on this in Significant Figures and the Uncertainty of Glassware.

Try it at home: is your measuring jug honest?

You need a measuring jug, a kitchen scale that reads to 1 g1\ \text{g}, a glass and water.

  1. Put the glass on the scale and press tare (zero).
  2. Fill the jug to its 100 mL100\ \text{mL} line, reading at eye level, and pour it all into the glass.
  3. Read the mass. Water has a density of almost exactly 1 g/mL1\ \text{g/mL} at room temperature, so the mass in grams is the volume in millilitres.
  4. Repeat three times and at a higher line (250 mL250\ \text{mL}). Work out the percentage difference from the jug's reading.

What you should see: kitchen jugs are often a few percent out, and pouring always leaves some water behind. That is the difference between "to contain" and "to deliver", and why chemists use pipettes for exact transfers.

Common mistakes

  • Measuring with a beaker because it has lines. Its marks are only about ±5%\pm 5\%.
  • Using a big cylinder for a small volume. The percentage uncertainty grows as the volume shrinks.
  • Rinsing a burette with water and filling it straight away. The solution inside is diluted and every titre comes out too big.
  • Heating a measuring cylinder or volumetric flask. Heating can change the volume of the glass permanently; only beakers, flasks, test tubes and porcelain are heated.
  • Writing 25 mL25\ \text{mL} for a pipette volume. It is 25.00 mL25.00\ \text{mL}.

Practice

  1. What is the percentage uncertainty of a 25.00 mL25.00\ \text{mL} Class B pipette (±0.06 mL\pm 0.06\ \text{mL})? And of a Class A one (±0.03 mL\pm 0.03\ \text{mL})?
Answer

0.0625.00×100%=0.24%\dfrac{0.06}{25.00} \times 100\% = 0.24\%; 0.0325.00×100%=0.12%\dfrac{0.03}{25.00} \times 100\% = 0.12\%.

  1. A 250 mL250\ \text{mL} volumetric flask is marked ±0.3 mL\pm 0.3\ \text{mL}. Find its percentage uncertainty.
Answer

0.3250×100%=0.12%\dfrac{0.3}{250} \times 100\% = 0.12\%.

  1. Why is a burette, not a pipette, used for the solution whose volume you are trying to find in a titration?
Answer

A pipette delivers only one fixed volume. The burette lets you add the solution a drop at a time and read exactly how much was needed, whatever it turns out to be.

  1. A student rinses the pipette with distilled water and then uses it straight away. Will the moles of acid delivered be too high, too low or unchanged?
Answer

Too low: the water left inside dilutes the first acid drawn up, so 25.00 mL25.00\ \text{mL} contains slightly less acid.

Test yourself

Which glassware is used to deliver exactly 25.00 mL25.00\ \text{mL} of a solution?

  1. A beaker
  2. A measuring cylinder
  3. A bulb pipette
  4. A conical flask

What is the reading uncertainty of a burette with 0.1 mL0.1\ \text{mL} divisions?

  1. ±0.1 mL\pm 0.1\ \text{mL}
  2. ±0.05 mL\pm 0.05\ \text{mL}
  3. ±0.01 mL\pm 0.01\ \text{mL}
  4. ±0.5 mL\pm 0.5\ \text{mL}

What should the burette be rinsed with just before it is filled?

  1. Distilled water
  2. Tap water
  3. A little of the solution it will hold
  4. Ethanol

Why may the conical flask be wet with distilled water when the acid is pipetted into it?

  1. Water makes the indicator work
  2. The amount of acid (moles) delivered by the pipette does not change
  3. Water speeds up the reaction
  4. It must always be dry