TExcelTAD
Home › Lab Skills: Safety, Glassware, Solutions & Titration › Percentage Uncertainty and Percentage Error

Percentage Uncertainty and Percentage Error

A question to start

The textbook says that 0.060 g0.060\ \text{g} of magnesium should give 62 mL62\ \text{mL} of hydrogen. Your gas syringe says 60 mL60\ \text{mL}. Did the experiment work? Or the label on the sodium hydroxide bottle says 0.100 mol/L0.100\ \text{mol/L} and your careful titration gives 0.0978 mol/L0.0978\ \text{mol/L}. Is the label wrong, or are you? Two numbers settle it.

The idea: compare the error with the uncertainty

Two percentages look alike but answer different questions.

Quantity What it asks Formula
percentage uncertainty (sai số tương đối) how precise is my measurement, judging by my apparatus? Δxx×100%\dfrac{\Delta x}{x} \times 100\%, added up over every measurement used
percentage error (sai số phần trăm so với giá trị chuẩn) how far is my result from the accepted (expected, true) value? ∣xexp−xacc∣xacc×100%\dfrac{\lvert x_{exp} - x_{acc} \rvert}{x_{acc}} \times 100\%
percentage error=∣experimental value−accepted value∣accepted value×100%\text{percentage error} = \frac{\lvert \text{experimental value} - \text{accepted value} \rvert}{\text{accepted value}} \times 100\%

Then compare:

  • percentage error ≤\le total percentage uncertainty: the difference can be explained by the limits of the apparatus. The result agrees with the accepted value. To do better, use more precise apparatus or larger quantities.
  • percentage error >> total percentage uncertainty: the apparatus cannot explain it. There is a systematic error in the method (or the "accepted" value does not apply). Find it.
565758596061626364measured 60.0 +- 2.5 mLexpected 61.98A: hydrogen from 0.060 g of Mg, at 25 C and 1 bar (mL)error 3.2 % < uncertainty 4.2 %: the result agrees0.0940.0960.0980.1000.102measured 0.0978 +- 0.0011label 0.100B: concentration of old NaOH solution (mol/L)error 2.2 % > uncertainty 1.1 %: a real difference

Random and systematic errors in chemistry

  • Random errors scatter repeated results both ways: judging the end-point colour, reading a meniscus, small draughts on a balance. Repeat and average to reduce them.
  • Systematic errors push every result the same way: a burette rinsed with water (titres too large), always reading from above, gas escaping before the bung is fitted (volumes too small), heat lost to the air in an energy experiment, an impure or damp solid. Repeating does not help; you must change the method.

The physics lesson Random and Systematic Errors has more examples.

Worked examples

Example 1: does the hydrogen volume agree? 0.060 g0.060\ \text{g} of magnesium reacts with excess hydrochloric acid at 25 ∘C25\,^\circ\text{C} and 1 bar1\ \text{bar}; the gas is collected in a 100 mL100\ \text{mL} gas syringe marked every 1 mL1\ \text{mL} and reads 60.0 mL60.0\ \text{mL}. The mass was found by difference on a 0.001 g0.001\ \text{g} balance.

Mg(s)+2 HCl(aq)→MgClX2(aq)+HX2(g)\ce{Mg(s) + 2HCl(aq) -> MgCl2(aq) + H2(g)}
  • Given: m=0.060 gm = 0.060\ \text{g} (±0.002 g\pm 0.002\ \text{g}), V=60.0 mLV = 60.0\ \text{mL} (±0.5 mL\pm 0.5\ \text{mL}), M(Mg)=24 g/molM(\ce{Mg}) = 24\ \text{g/mol}, molar volume 24.79 L/mol24.79\ \text{L/mol} at 25 ∘C25\,^\circ\text{C} and 1 bar1\ \text{bar}.
  • Find: the expected volume, the percentage error and the total percentage uncertainty.
  • Formula: n=mMn = \dfrac{m}{M}; V=n×24.79 L/molV = n \times 24.79\ \text{L/mol}; percentage error and uncertainty as above.
  • Solve: n(Mg)=0.06024=0.0025 mol=n(HX2)n(\ce{Mg}) = \dfrac{0.060}{24} = 0.0025\ \text{mol} = n(\ce{H2}); Vacc=0.0025×24.79 L=0.06198 L=61.98 mLV_{acc} = 0.0025 \times 24.79\ \text{L} = 0.06198\ \text{L} = 61.98\ \text{mL}. Percentage error =61.98−60.061.98×100%=3.2%= \dfrac{61.98 - 60.0}{61.98} \times 100\% = 3.2\%. Uncertainty =0.0020.060×100%+0.560.0×100%=3.33%+0.83%=4.2%= \dfrac{0.002}{0.060} \times 100\% + \dfrac{0.5}{60.0} \times 100\% = 3.33\% + 0.83\% = 4.2\%.
  • Answer: the 3.2%3.2\% error is smaller than the 4.2%4.2\% uncertainty: the result agrees with theory.
  • Check: almost all the uncertainty comes from weighing such a tiny mass. To test the theory more sharply, weigh more magnesium (but keep the gas below 100 mL100\ \text{mL}) or use a 0.0001 g0.0001\ \text{g} balance.

Example 2: is the label wrong? A titration gives c(NaOH)=0.0978 mol/Lc(\ce{NaOH}) = 0.0978\ \text{mol/L} with a total uncertainty of 1.13%1.13\% (pipette 0.24%0.24\%, titre 0.39%0.39\%, standard acid 0.50%0.50\%). The label says 0.100 mol/L0.100\ \text{mol/L}.

  • Given: cexp=0.0978 mol/Lc_{exp} = 0.0978\ \text{mol/L}, cacc=0.100 mol/Lc_{acc} = 0.100\ \text{mol/L}, uncertainty 1.13%1.13\%.
  • Find: the percentage error; compare.
  • Formula: percentage error =∣cexp−cacc∣cacc×100%= \dfrac{\lvert c_{exp} - c_{acc} \rvert}{c_{acc}} \times 100\%.
  • Solve: 0.100−0.09780.100×100%=2.2%\dfrac{0.100 - 0.0978}{0.100} \times 100\% = 2.2\%.
  • Answer: 2.2%>1.13%2.2\% > 1.13\%: the difference is real. Either the method has a systematic error, or the solution really is weaker than the label. Sodium hydroxide solutions slowly absorb carbon dioxide from the air, 2 NaOH(aq)+COX2(g)→NaX2COX3(aq)+HX2O(l)\ce{2NaOH(aq) + CO2(g) -> Na2CO3(aq) + H2O(l)}, so an old bottle does get weaker. That is why NaOH\ce{NaOH} solutions are always standardised by titration before use.
  • Check: the figure above: the label value lies outside the result's uncertainty band.

Example 3: which way does the error push? For each mistake in a titration of acid (in the flask) with alkali (in the burette), say whether the calculated acid concentration comes out too high or too low. (a) The burette was rinsed with water only. (b) The conical flask was wet with distilled water. (c) The end point was overshot every time.

  • Solve: (a) the alkali is diluted, so more is needed: titre too big, acid concentration too high. (b) the moles of acid are unchanged: no effect. (c) titres too big: too high.
  • Answer: (a) high, (b) no effect, (c) high. All of (a) and (c) are systematic: repeating them gives the same wrong answer.

Try it at home: is a millilitre of water a gram?

You need a kitchen scale that reads to 1 g1\ \text{g}, a measuring jug and water.

  1. Put the jug on the scale and tare it.
  2. Pour water to the 200 mL200\ \text{mL} mark (eye level!) and read the mass.
  3. The accepted density of water at room temperature is 1.00 g/mL1.00\ \text{g/mL}, so the accepted mass is 200 g200\ \text{g}. Work out your percentage error.
  4. Work out your percentage uncertainty: jug ±\pm half a division (for example ±12.5 mL\pm 12.5\ \text{mL} for 25 mL25\ \text{mL} marks), scale ±2 g\pm 2\ \text{g}.
  5. Is your error smaller than your uncertainty?

What you should find: typically an error of a few percent and an uncertainty of about 7%7\%: the jug, not the scale, limits you.

Common mistakes

  • Calling the percentage error "the uncertainty". The error needs an accepted value; the uncertainty comes from your apparatus.
  • Forgetting to add all the uncertainties of all the measurements used.
  • Blaming "human error" in an evaluation. Name the actual cause (parallax, end point overshot, gas lost before the bung was fitted) and say which way it pushes the result.
  • Thinking a big uncertainty is "an error". It just means the result cannot be more exact with that apparatus.

Practice

  1. A student finds x=4.6x = 4.6 water molecules per formula unit in hydrated copper(II) sulfate; the accepted value is 55. Find the percentage error.
Answer

5−4.65×100%=8%\dfrac{5 - 4.6}{5} \times 100\% = 8\%.

  1. The total percentage uncertainty in that experiment was 3%3\%. What does that tell you, and give one likely cause.
Answer

8%>3%8\% > 3\%: a systematic error. The crystals were probably not heated to constant mass, so some water was still there and xx came out low (see Heating Safely).

  1. A titration result for c(HCl)c(\ce{HCl}) is 0.1012 mol/L0.1012\ \text{mol/L}, uncertainty 0.9%0.9\%; the accepted value is 0.1000 mol/L0.1000\ \text{mol/L}. Does it agree?
Answer

Percentage error =0.00120.1000×100%=1.2%>0.9%= \dfrac{0.0012}{0.1000} \times 100\% = 1.2\% > 0.9\%: just outside; look for a systematic error (for example, the burette not rinsed with the alkali).

Test yourself

A result is 0.0978 mol/L0.0978\ \text{mol/L}; the accepted value is 0.100 mol/L0.100\ \text{mol/L}. What is the percentage error?

  1. 0.22%0.22\%
  2. 2.2%2.2\%
  3. 9.78%9.78\%
  4. 97.8%97.8\%

The percentage error is 5%5\% and the total percentage uncertainty is 1%1\%. What can you conclude?

  1. The result agrees with the accepted value
  2. There is probably a systematic error in the method
  3. The apparatus is too precise
  4. Nothing at all

Which of these is a systematic error?

  1. Judging the end point slightly differently each time
  2. Always reading the burette from above
  3. A draught making the balance reading flicker
  4. Rounding the last digit

The burette is rinsed with water but not with the alkali. How does this affect the calculated acid concentration?

  1. Too low
  2. Too high
  3. No effect
  4. It depends on the indicator