TExcelTAD
Home › Lab Skills: Safety, Glassware, Solutions & Titration › Recording Data and Writing a Lab Report

Recording Data and Writing a Lab Report

A question to start

A week after the practical, you open your notebook and find: "25, 24.1, 24.15ish, 0.1 M?". Which numbers were readings and which were calculated? What was the unit? Was the acid 0.10.1 or 0.100 mol/L0.100\ \text{mol/L}? A lab report exists so that anyone, including you next week, can see exactly what was done and how sure the answer is.

The idea: record raw data at once, then process and evaluate

title + aimriskmethodraw resultsprocessingconclusionevaluationwhat you measured, with units and uncertaintieserrors, % uncertainty vs % error, improvements
Section What goes in it
Title and aim what you are finding: "To find the concentration of a sodium hydroxide solution by titration with 0.1000 mol/L0.1000\ \text{mol/L} hydrochloric acid"
Risk assessment hazards, risks and control measures (Lab Rules and Risk Assessment)
Method numbered steps in the past or imperative tense, apparatus with sizes ("25.00 mL25.00\ \text{mL} pipette", not "a pipette"), so someone else could repeat it
Raw results (số liệu thô) every reading exactly as measured, in a table, recorded at the time in ink
Processing calculations with formulas, units and significant figures, uncertainties
Conclusion the answer to the aim, with its uncertainty, compared with any accepted value
Evaluation the main sources of uncertainty and of systematic error, which way each pushes the result, and specific improvements

Tables of results

  • One column (or row) per quantity, headed quantity / unit: "final reading / mL", so the cells hold only numbers.
  • Every reading to the precision of the instrument, all with the same number of decimal places for one instrument: 24.2024.20, not 24.224.2.
  • Calculated values (the titre) can be in the same table, clearly labelled.
  • If you make a mistake, cross it out with one line so it can still be read; do not overwrite or erase.

The physics course covers tables, graphs and error bars in detail; the rules are the same in chemistry: Data Tables, Plotting Graphs, Error Bars and the Uncertainty of a Gradient and Writing a Lab Report.

Graphs in chemistry

Chemistry uses graphs for rates (volume of gas against time), for calibration curves (absorbance against concentration), for heating curves and for titration curves (pH against volume). Plot the independent variable across, draw a smooth curve or a line of best fit with points scattered on both sides, and ignore clear anomalies (circle them and say why).

The simulation shows the idea of a best-fit line on a physics example: adjust the gradient until the sum of the squared distances to the points is as small as possible.

00.10.20.30.40.50.60.701234I (A)U (V)your lineleast-squares fitsteepest / shallowestyour gradient: 4.20 Ωyour Σr² = 0.0702best gradient: 4.770 Ωintercept: 0.086 Vbest Σr² = 0.0134 (least)steepest: 5.28 Ωshallowest: 4.32 ΩΔm = half the gap = 0.48resistance R:4.8 ± 0.5 Ωerror bars ±0.12 V

With these six points the best gradient is 4.774.77, the steepest and shallowest acceptable lines 5.285.28 and 4.324.32, so the gradient is 4.8±0.54.8 \pm 0.5: half the difference between the steepest and shallowest lines.

Quantity table for this lesson

Quantity Symbol Unit
burette reading VV mL (2 d.p.)
titre VtitreV_{titre} mL
concentration cc mol/L
percentage uncertainty %\%
percentage error %\%

Worked examples

Example 1: fix the table. A student wrote:

Run Start End Titre
1 0 24.2 24.2 mL
2 0.3 24.45 24.15
  • Answer: the headers need units ("initial reading / mL"), units go in the header, not in the cells, and every burette reading needs two decimal places: 0.000.00, 24.2024.20, 24.2024.20; 0.300.30, 24.4524.45, 24.1524.15.

Example 2: a conclusion that says something. Weak: "The concentration of NaOH was 0.0978." Strong: "The concentration of the sodium hydroxide solution was (0.0978±0.0011) mol/L(0.0978 \pm 0.0011)\ \text{mol/L} (uncertainty 1.1%1.1\%). The label value of 0.100 mol/L0.100\ \text{mol/L} differs by 2.2%2.2\%, more than the uncertainty, so the solution has probably absorbed carbon dioxide from the air."

Example 3: an evaluation point. Weak: "Human error." Strong: "The end point was judged by eye, and the first faint pink may have been missed by one drop (0.05 mL0.05\ \text{mL}). This makes each titre up to 0.05 mL0.05\ \text{mL} too large, about 0.2%0.2\% of 24.15 mL24.15\ \text{mL}. A white tile and adding the last drops more slowly would reduce it."

  • Check: a good evaluation point names the cause, gives its direction and size, and suggests a specific improvement.

Try it at home: a kitchen lab notebook

Take any kitchen activity from this course (the sugar solution, the food colouring dilution series, the salt crystals) and write it up on one page with all seven sections. Use a table with headers "quantity / unit" and record every reading the moment you take it.

What you should find: the hardest part is the evaluation. What limited you most: the scale, the jug, or your eye?

Common mistakes

  • Writing results on scrap paper and copying them "neatly" later.
  • Units in every cell instead of the header.
  • Inconsistent decimal places for one instrument.
  • A conclusion without an uncertainty or without a comparison.
  • "Human error" as an evaluation.
  • Joining the points dot to dot instead of drawing a best-fit line or smooth curve.

Practice

  1. Write a correct column header for the mass of a crucible measured on a 0.01 g0.01\ \text{g} balance, and write 27.527.5 correctly in it.
Answer

"mass of crucible / g"; 27.5027.50.

  1. Give one evaluation point for a gas-collection experiment where the bung was fitted after the reaction had started.
Answer

Some gas escaped before the bung was fitted, so the volume collected is too small (systematic). Improvement: put the solid in a small tube inside the flask, fit the bung, then tip the tube over to start the reaction.

  1. Which section of the report should say "Wear eye protection; sodium hydroxide is corrosive"?
Answer

The risk assessment.

Test yourself

How should the column for burette readings be headed?

  1. Burette (mL readings)
  2. final reading / mL
  3. mL
  4. final reading

When should raw data be recorded?

  1. At the end of the lesson
  2. At home, neatly
  3. Immediately, as each reading is taken
  4. Only if the results look right

Which is the best evaluation point?

  1. Human error made the result wrong
  2. The experiment was not accurate
  3. The end point may have been overshot by one drop, making each titre up to 0.05 mL0.05\ \text{mL} too large; add the last drops more slowly
  4. We should do it again

What must a conclusion contain?

  1. Only the calculation
  2. The answer to the aim with its unit and uncertainty, compared with any accepted value
  3. A list of apparatus
  4. The risk assessment