Poynting's Theorem and Power Flow
Where does the energy travel when a battery lights a lamp through two wires? The intuitive answer, "inside the copper, carried by the electrons", is wrong: the electrons drift at fractions of a millimetre per second, and the copper is where energy is lost, not where it flows. Poynting's theorem answers the question exactly. Energy flows through the space around and between the conductors, guided by them, at a rate given by the Poynting vector . The same vector gives the power carried by a radio wave, the power absorbed by a wall or by a human body, and the numbers used in RF exposure limits.
Poynting's theorem
Start from Maxwell's two curl equations (Maxwell's Equations), dot the first with and the second with , subtract and use the identity . For a simple medium with , integrated over a volume with surface (divergence theorem, Integral Theorems):
Read it as an energy balance. The power flowing into the closed surface equals the rate of increase of stored electric and magnetic energy inside plus the power turned into heat (ohmic loss). The flux of (W/m) is therefore the power crossing a surface; only its integral over a closed surface is guaranteed meaningful, but in practice is used as the local power flow density.
Time-harmonic fields. With peak phasors (Time-Harmonic Fields) the time average is
where is the angle of the intrinsic impedance (zero in a lossless medium, so ). The factor is the same one as in for peak circuit phasors (AC Power, which uses rms values and drops it).
Two DC examples that change how you see circuits
A resistance wire. A current flows along a straight wire of radius , length and resistance . Inside and at its surface the electric field points along the wire, ; the magnetic field circles it, at the surface (Ampère, Ampère's Circuital Law). points radially into the wire. Multiply by the surface area:
The heat in a resistor arrives through its surface, from the field outside.
A coaxial cable feeding a load. Between the conductors and , so points along the cable towards the load, and its integral over the annulus is exactly . The energy travels in the insulation; the copper only guides it and loses a little. That is the field picture behind every transmission line (The Distributed Line).
Worked example
Given: the wire in the figure: nichrome, resistivity (a typical handbook value), radius , length , current .
Find: , , the fields at the surface, , and the total power through the surface.
Solve:
Check: , the same. Units: .
In Python
The script repeats the wire, integrates over a coax cross-section carrying and , computes of the elliptical wave from Wave Polarisation from its phasors, and then estimates RF exposure from transmitters.
import numpy as np
from scipy.integrate import quad
# 1. A resistance wire: power enters through its surface
rho_nicr, a, length, current = 1.1e-6, 0.25e-3, 1.0, 2.0
r = rho_nicr * length / (np.pi * a**2)
v = current * r
e_surf = v / length # tangential E at the surface
h_surf = current / (2 * np.pi * a) # H at the surface (Ampere)
s_in = e_surf * h_surf # |E x H|, pointing into the wire
print(f"wire: R = {r:.3f} Ohm, V = {v:.3f} V, I^2 R = {current**2 * r:.3f} W")
print(f" E = {e_surf:.3f} V/m, H = {h_surf:.1f} A/m, S = {s_in:.0f} W/m^2 inwards")
print(f" S x surface area = {s_in * 2 * np.pi * a * length:.3f} W")
# 2. A coax carrying DC to a load: power flows in the insulation
vdc, idc, ri, ro = 12.0, 2.0, 0.45e-3, 1.475e-3
def sz(rho): # E_rho * H_phi
return vdc / (rho * np.log(ro / ri)) * idc / (2 * np.pi * rho)
p, _ = quad(lambda rho: sz(rho) * 2 * np.pi * rho, ri, ro)
print(f"coax: integral of S_z over the annulus = {p:.4f} W, VI = {vdc * idc:.1f} W")
print(f" S_z at the inner conductor {sz(ri)/1e6:.2f} MW/m^2, at the outer {sz(ro)/1e6:.3f} MW/m^2")
# 3. Plane wave from phasors: S_av = Re(E x H*)/2
eta0 = 376.73
E = np.array([10.0, 5.0j, 0]) # peak phasor, V/m (an elliptical wave)
H = np.cross([0, 0, 1], E) / eta0 # H = z x E / eta for travel in +z
s_av = 0.5 * np.real(np.cross(E, np.conj(H))) + 0.0
print(f"plane wave: S_av = ({s_av[0]:.4f}, {s_av[1]:.4f}, {s_av[2]:.4f}) W/m^2")
# 4. Far-field power density of a source with a given EIRP
def s_far(eirp, d):
return eirp / (4 * np.pi * d**2)
for name, eirp, f_mhz, d in [("Wi-Fi router", 0.1, 2400, 0.2), ("Wi-Fi router", 0.1, 2400, 1.0),
("base-station sector", 2000, 1800, 10.0), ("base-station sector", 2000, 1800, 50.0)]:
limit = 10.0 if f_mhz >= 2000 else f_mhz / 200 # ICNIRP 2020 general public, whole body
s = s_far(eirp, d)
print(f"{name:<20} EIRP {eirp:7.1f} W at {d:5.1f} m: S = {s:9.4f} W/m^2 = {100*s/limit:6.2f} % of {limit:.0f} W/m^2")
for eirp, f_mhz in [(0.1, 2400), (2000, 1800)]:
limit = 10.0 if f_mhz >= 2000 else f_mhz / 200
print(f"EIRP {eirp:g} W: S falls to the reference level at {np.sqrt(eirp / (4 * np.pi * limit)):.3f} m")wire: R = 5.602 Ohm, V = 11.205 V, I^2 R = 22.409 W
E = 11.205 V/m, H = 1273.2 A/m, S = 14266 W/m^2 inwards
S x surface area = 22.409 W
coax: integral of S_z over the annulus = 24.0000 W, VI = 24.0 W
S_z at the inner conductor 15.89 MW/m^2, at the outer 1.479 MW/m^2
plane wave: S_av = (0.0000, 0.0000, 0.1659) W/m^2
Wi-Fi router EIRP 0.1 W at 0.2 m: S = 0.1989 W/m^2 = 1.99 % of 10 W/m^2
Wi-Fi router EIRP 0.1 W at 1.0 m: S = 0.0080 W/m^2 = 0.08 % of 10 W/m^2
base-station sector EIRP 2000.0 W at 10.0 m: S = 1.5915 W/m^2 = 17.68 % of 9 W/m^2
base-station sector EIRP 2000.0 W at 50.0 m: S = 0.0637 W/m^2 = 0.71 % of 9 W/m^2
EIRP 0.1 W: S falls to the reference level at 0.028 m
EIRP 2000 W: S falls to the reference level at 4.205 m
The coax carries most of its power close to the inner conductor, where is ten times larger than at the outer one: the reason the inner radius and the insulation there decide a cable's power and voltage ratings. The plane-wave line reproduces the of the polarisation lesson, all of it along .
RF exposure: a dated fact to calculate with
Strong radio-frequency fields heat tissue. The international guideline used by most countries is ICNIRP (2020), Guidelines for limiting exposure to electromagnetic fields (100 kHz to 300 GHz). Its whole-body reference levels for the general public, as incident power density averaged over minutes, are (as published in 2020; national rules may differ and are revised):
| Frequency | Reference level (general public, whole body) |
|---|---|
| to | with in MHz (e.g. at ) |
| to |
Occupational levels are five times higher, and separate local (small-area) reference levels, averaged over minutes instead of , apply to exposure of part of the body; the whole-body levels are averages over the space the body occupies. In the far field of an antenna, with EIRP the effective isotropic radiated power. The table above shows a Wi-Fi router at at of the level (and is barely in its far field, so treat that as an estimate), and a EIRP base-station sector falling below the level about in front of its antenna. Real compliance assessments follow measurement and calculation standards (IEC 62232:2025, edition 4.0, for base stations) and include near-field effects; in this course exposure is calculated only.
Interactive: power density of a plane wave
At the general-public level is , which a plane wave in free space reaches at a peak field . Set the lab to and : it reads and . Halve and drops to a quarter. (ICNIRP quotes field-strength levels as rms values, here.)
Guided lab: the wire's power budget
Hand calculation. The worked example: , , , , all of it arriving through the surface at .
Simulation. The script above; change the wire radius and watch stay fixed for a given while and grow as the surface shrinks.
What you would measure. Stretch of nichrome wire between two terminal blocks on a non-flammable board (ceramic tile). Bench supply: current limit , voltage up to . Read across the wire (four-wire, at the wire's ends, not at the supply) and from a meter in series: expect about at when cold, rising a little as the wire warms (nichrome's resistance changes by only a few per cent up to a few hundred degrees). to about . You cannot measure directly at DC, but the agreement of with is the theorem at work.
Hazards and safe setup. The wire reaches a few hundred degrees Celsius at per metre in still air: keep it off wood, plastic and fingers, and let it cool before touching. Low voltage, current-limited supply only.
Pitfalls
- Forgetting the with peak phasors, or adding one with rms phasors.
- Integrating over an open surface and expecting a unique answer. can circulate (e.g. near a charged magnet) without carrying net power; only closed-surface fluxes are unambiguous.
- Using the far-field formula too close. needs several wavelengths and larger than for an antenna of size (Radiation).
- Testing exposure limits. Never stand in front of a transmitting antenna or open a microwave oven to "see": exposure is calculated or measured by qualified people with calibrated probes.
Practice
- A plane wave in a lossless dielectric with has . Find .
- A coax carries to a matched load. What are and (rms), and in which material does the power travel?
- At what distance does a EIRP source at reach the ICNIRP 2020 general-public level?
Answer
- .
- , ; the power flows in the dielectric between the conductors.
- .
Test yourself
In a resistor carrying DC, the electromagnetic energy that becomes heat enters…
- along the inside of the conductor from the battery
- through the resistor's surface from the surrounding field
- only at the resistor's two ends
- it does not come from the field
The time-averaged Poynting vector for peak phasors is…
- always
In a coax carrying power to a load, where is largest?
- inside the inner conductor
- next to the inner conductor, in the dielectric
- next to the outer conductor
- it is uniform
A source has EIRP. In its far field, doubling the distance changes the power density by…
- no change