TExcelTAD

Faraday's and Lenz's Laws

Put a scope probe on a small coil and hold it near the cable from a function generator: a voltage appears although nothing touches the cable. Wrap a laminated core with two windings and the second winding delivers power it never touched. Leave a solid iron core in the same transformer and it gets hot. All three are electromagnetic induction: a magnetic flux that changes in time creates an electric field that circulates. This lesson states Faraday's law in integral and point form, gets the sign right with Lenz's law, and computes the voltage a pickup coil sees near a wire. The school version (a magnet pushed into a coil) is in Faraday's Law and Lenz's Law; here the aim is the field picture that engineers use for transformers, pickup loops and eddy currents.

Intuition: the magnet and the coil

SNvNSinducedIN pole moving in: the coil's near end becomes N and pushes it backG−137 mVΦ (mWb)t0.147moving inmoving outℰ (mV)t137−137moving inmoving out

The lab's flux per turn peaks at 0.147 mWb0.147\ \text{mWb} when the magnet sits in the coil (t=1.5 st = 1.5\ \text{s}), yet the EMF there is zero: the flux is large but not changing. The EMF peaks while the flux changes fastest, about −137 mV-137\ \text{mV} near t=1.07 st = 1.07\ \text{s} with 300300 turns. Switch to 500500 turns and the peak grows by 5/35/3 to −228 mV-228\ \text{mV}; switch to the slow push and it halves to 68 mV68\ \text{mV}. Faraday's law in two experiments: the EMF is proportional to the number of turns and to the rate of change of flux. Watch the coil's near end: it becomes an N pole as the N pole approaches (repelling it) and an S pole as it leaves (attracting it). That is Lenz's law.

Faraday's law

For a closed path CC bounding a surface SS,

E=∮CE⋅dl=−ddt∫SB⋅dS=−dΦdt\mathcal{E} = \oint_C \mathbf{E} \cdot d\mathbf{l} = -\frac{d}{dt}\int_S \mathbf{B} \cdot d\mathbf{S} = -\frac{d\Phi}{dt}

with dld\mathbf{l} and dSd\mathbf{S} related by the right-hand rule (fingers along CC, thumb along dSd\mathbf{S}). A coil of NN turns links the flux NN times: E=−N dΦ/dt=−dλ/dt\mathcal{E} = -N\,d\Phi/dt = -d\lambda/dt, where λ=NΦ\lambda = N\Phi is the flux linkage (Wb-turns). When the path is fixed and only B\mathbf{B} changes, the time derivative moves inside the integral, and Stokes' theorem (Stokes' Theorem, the integral theorems) turns the law into its point form:

∇×E=−∂B∂t\nabla \times \mathbf{E} = -\frac{\partial \mathbf{B}}{\partial t}

This one line overturns electrostatics. There, ∇×E=0\nabla \times \mathbf{E} = 0 and E=−∇V\mathbf{E} = -\nabla V, so the integral of E\mathbf{E} between two points did not depend on the path (Electric Potential). With a changing B\mathbf{B}, E\mathbf{E} has a circulating part, and the voltage between two points depends on the path. A scope probe and its ground lead form a loop; any changing flux through that loop adds to what the scope shows. That is why fast signals are probed with a short ground spring rather than a long clip lead (Probes).

A moving conductor adds a second EMF, (v×B)⋅dl(\mathbf{v} \times \mathbf{B}) \cdot d\mathbf{l}, which is the subject of Motional EMF and Generators. This lesson treats stationary circuits: the transformer EMF.

Lenz's law: the sign

The minus sign says that the induced EMF drives a current whose own magnetic field opposes the change in flux. It is energy conservation: if the induced current reinforced the change, a small push would grow without limit. In practice:

  1. Find the direction of B\mathbf{B} through the loop and whether the flux is growing or shrinking.
  2. The induced current makes a field through the loop opposite to the change: opposite to B\mathbf{B} if the flux grows, along B\mathbf{B} if it shrinks.
  3. The right-hand rule turns that field direction into a current direction.

Worked example: a pickup coil beside a wire

i(t) xxx xxx xxx 1 cm 2 cm wide 4 cm pickup coil, N = 20 x : B into the page induced current while i rises (counter-clockwise: its field points out) B = mu0 i / (2 pi r)

Given: a long straight wire carries i(t)=I0sin⁡ωti(t) = I_0 \sin \omega t with I0=0.1 AI_0 = 0.1\ \text{A} and f=100 kHzf = 100\ \text{kHz}. A rectangular pickup coil of N=20N = 20 turns lies in the same plane, ℓ=4 cm\ell = 4\ \text{cm} along the wire, its sides r1=1 cmr_1 = 1\ \text{cm} and r2=3 cmr_2 = 3\ \text{cm} from it.

Find: the mutual inductance MM between wire and coil, the peak EMF, and its direction while ii rises.

Solve: the wire's field is B=μ0i/(2πr)B = \mu_0 i/(2\pi r) (Ampère's Law), normal to the coil. Strips of width drdr and length ℓ\ell carry flux Bℓ drB\ell\,dr:

Φ=∫r1r2μ0i2πr ℓ dr=μ0ℓ2πln⁡r2r1 i=(2×10−7)(0.04)(ln⁡3) i=8.789 nWb/A⋅iM=NΦi=20⋅8.789 nH=175.8 nHEpeak=ωMI0=(2π⋅105 s−1)(175.8×10−9 H)(0.1 A)=11.0 mV\begin{aligned} \Phi &= \int_{r_1}^{r_2} \frac{\mu_0 i}{2\pi r}\,\ell\,dr = \frac{\mu_0 \ell}{2\pi}\ln\frac{r_2}{r_1}\, i = (2 \times 10^{-7})(0.04)(\ln 3)\, i = 8.789\ \text{nWb/A} \cdot i \\ M &= \frac{N\Phi}{i} = 20 \cdot 8.789\ \text{nH} = 175.8\ \text{nH} \\ \mathcal{E}_\text{peak} &= \omega M I_0 = (2\pi \cdot 10^5\ \text{s}^{-1})(175.8 \times 10^{-9}\ \text{H})(0.1\ \text{A}) = 11.0\ \text{mV} \end{aligned}

While ii rises, the flux into the page grows, so the induced current flows counter-clockwise (its field points out of the page). Since E=−M di/dt\mathcal{E} = -M\,di/dt, the EMF is a cosine: largest as the current crosses zero.

Check: units: H⋅A/s=V\text{H} \cdot \text{A/s} = \text{V}. The EMF scales with ff: 0.11 mV0.11\ \text{mV} at 1 kHz1\ \text{kHz}, which is why pickup coils and current probes for low frequencies need many turns or a magnetic core (Mutual Inductance).

In Python

python · try it yourself
import numpy as np
from scipy.integrate import quad

MU0 = 4e-7 * np.pi
I0, F = 0.1, 100e3            # wire current peak (A) and frequency (Hz)
N, L = 20, 0.04               # pickup turns, side parallel to the wire (m)
R1, R2 = 0.01, 0.03           # near and far side distances from the wire (m)

# flux per ampere through one turn: integrate B = mu0 I/(2 pi r) over the loop
phi_num = quad(lambda r: MU0 / (2 * np.pi * r) * L, R1, R2)[0]
phi_exact = MU0 * L / (2 * np.pi) * np.log(R2 / R1)
M = N * phi_exact
print(f"flux per turn per ampere: numerical {phi_num*1e9:.4f} nWb/A, exact {phi_exact*1e9:.4f} nWb/A")
print(f"mutual inductance M = N*phi/I = {M*1e9:.1f} nH")

# EMF = -N dPhi/dt for i(t) = I0 sin(wt): sample one period and differentiate numerically
w = 2 * np.pi * F
t = np.linspace(0, 1 / F, 4001)
flux = N * phi_exact * I0 * np.sin(w * t)
emf = -np.gradient(flux, t)
print(f"peak EMF: numerical {emf.max()*1e3:.2f} mV, formula w*M*I0 = {w*M*I0*1e3:.2f} mV")
print(f"EMF at t = 0 (current rising through zero): {emf[0]*1e3:+.2f} mV")
for f in [1e3, 10e3, 100e3, 1e6]:
    print(f"  f = {f:9.0f} Hz: peak EMF {2*np.pi*f*M*I0*1e3:8.3f} mV")
flux per turn per ampere: numerical 8.7889 nWb/A, exact 8.7889 nWb/A
mutual inductance M = N*phi/I = 175.8 nH
peak EMF: numerical 11.04 mV, formula w*M*I0 = 11.04 mV
EMF at t = 0 (current rising through zero): -11.04 mV
  f =      1000 Hz: peak EMF    0.110 mV
  f =     10000 Hz: peak EMF    1.104 mV
  f =    100000 Hz: peak EMF   11.044 mV
  f =   1000000 Hz: peak EMF  110.445 mV

The negative value at t=0t = 0 is the minus sign of Faraday's law with the coil's positive direction taken clockwise (thumb into the page, along B\mathbf{B}): the EMF drives current the other way, counter-clockwise, exactly as Lenz's law predicted.

Eddy currents and laminations

A changing flux induces a circulating E\mathbf{E} inside any conductor it passes through, and that field drives eddy currents (J=σE\mathbf{J} = \sigma\mathbf{E}). They heat the conductor and, by Lenz's law, push the flux out. For a sheet of thickness dd in a uniform field B0sin⁡ωtB_0 \sin \omega t along the sheet, and as long as dd is small compared with the skin depth, the average eddy-current loss per unit volume is

peddy=σ ω2B02d224p_\text{eddy} = \frac{\sigma\,\omega^2 B_0^2 d^2}{24}

It grows as d2d^2, so transformer and motor cores are stacks of thin insulated laminations (typically 0.230.23 to 0.65 mm0.65\ \text{mm} silicon steel at 5050 to 60 Hz60\ \text{Hz}, the thinner grades in transformers), ferrites (almost insulating) at tens of kilohertz and above, and powdered-iron cores in between (Magnetic Materials). The same physics is put to use in induction hobs, eddy-current brakes and metal detectors. When the conductor is thick compared with the skin depth, the eddy currents confine the field to a surface layer: Lossy Media, Skin Depth and Skin Effect.

Guided lab: measure the pickup voltage

Hand calculation. The worked example, scaled to your geometry: M=Nμ0ℓln⁡(r2/r1)/(2π)M = N\mu_0\ell\ln(r_2/r_1)/(2\pi), Epeak=ωMI0\mathcal{E}_\text{peak} = \omega M I_0.

Simulation. The Python script with your dimensions; the induction lab for the dependence on NN and speed.

What you would measure. A function generator set to 5 V5\ \text{V} peak at 100 kHz100\ \text{kHz} drives a 50 Ω50\ \Omega resistor (2 W2\ \text{W} rating; it dissipates 0.25 W0.25\ \text{W}) through a straight wire about 30 cm30\ \text{cm} long; route the return wire about 20 cm20\ \text{cm} away on the far side of the main wire, so its opposing flux through the coil is only ln⁡(23/21)/ln⁡3≈8 %\ln(23/21)/\ln 3 \approx 8\ \% of the main wire's (correct for it, or move the return further away). Measure the current as the voltage across the resistor: 0.1 A0.1\ \text{A} peak. Wind 20 turns of thin enamelled wire on a 4×2 cm4 \times 2\ \text{cm} card frame, tape it flat beside the wire with its near side at 1 cm1\ \text{cm}, and connect it to the scope with a short twisted pair and the probe at ×1\times 1 or straight into a 1 MΩ1\ \text{M}\Omega input. Expect about 11 mV11\ \text{mV} peak, leading the current by 90∘90^\circ (a cosine against a sine), and the sign flips if you turn the coil over. The uncertainty is dominated by geometry: a 1 mm1\ \text{mm} error in r1r_1 changes ln⁡(r2/r1)\ln(r_2/r_1) by about 9 %9\ \%; together with the return-wire correction and the coil's finite winding thickness, agreement within 1010 to 15 %15\ \% is good. Move the coil away and confirm the ln⁡(r2/r1)\ln(r_2/r_1) dependence; swap 100 kHz100\ \text{kHz} for 10 kHz10\ \text{kHz} and confirm the factor of ten.

Hazards and safe setup. Signal-generator levels only. The 50 Ω50\ \Omega resistor warms up; use a 2 W2\ \text{W} part. Never try this beside a mains cable: the principle is the same, but mains wiring is not part of this course's bench work.

Pitfalls

  • Flux large is not EMF large. The EMF depends on dΦ/dtd\Phi/dt, not on Φ\Phi.
  • Forgetting NN. A coil links the flux once per turn.
  • Treating induced voltage as a potential difference. With ∂B/∂t≠0\partial\mathbf{B}/\partial t \neq 0, two voltmeters connected to the same two points by different paths can read different values.
  • Lenz's law applied to B\mathbf{B} instead of its change. The induced field opposes the change: when the flux is shrinking, the induced field points along B\mathbf{B}.

Practice

  1. A 200200-turn coil of area 5 cm25\ \text{cm}^2 sits in a uniform field that rises from 00 to 0.3 T0.3\ \text{T} in 10 ms10\ \text{ms} at a steady rate. Find the EMF.
  2. In the worked example, what peak EMF does the coil see at 50 kHz50\ \text{kHz} if it is moved so that r1=2 cmr_1 = 2\ \text{cm} and r2=4 cmr_2 = 4\ \text{cm}?
  3. A sheet of thickness 0.5 mm0.5\ \text{mm} is replaced by laminations of 0.25 mm0.25\ \text{mm}. By what factor does the eddy-current loss per unit volume change?
Answer
  1. E=NA dB/dt=200⋅5×10−4⋅30 T/s=3.0 V\mathcal{E} = N A\,dB/dt = 200 \cdot 5 \times 10^{-4} \cdot 30\ \text{T/s} = 3.0\ \text{V}.
  2. M=20⋅2×10−7⋅0.04⋅ln⁡2=110.9 nHM = 20 \cdot 2 \times 10^{-7} \cdot 0.04 \cdot \ln 2 = 110.9\ \text{nH}; E=2π⋅5×104⋅110.9×10−9⋅0.1=3.48 mV\mathcal{E} = 2\pi \cdot 5 \times 10^4 \cdot 110.9 \times 10^{-9} \cdot 0.1 = 3.48\ \text{mV}.
  3. Loss scales as d2d^2: (0.25/0.5)2=1/4(0.25/0.5)^2 = 1/4.

Test yourself

In the induction lab the flux through the coil is largest when the magnet sits inside it. The EMF at that moment is…

  1. largest
  2. zero
  3. equal to NΦN\Phi
  4. negative and largest

What does ∇×E=−∂B/∂t\nabla \times \mathbf{E} = -\partial \mathbf{B}/\partial t imply for the voltage between two points?

  1. it is always path-independent
  2. it can depend on the path when B\mathbf{B} changes
  3. it is zero
  4. it equals the flux

A pickup coil has M=175.8 nHM = 175.8\ \text{nH} to a wire carrying 0.1 A0.1\ \text{A} peak at 100 kHz100\ \text{kHz}. The peak EMF is about…

  1. 1.1 mV1.1\ \text{mV}
  2. 11 mV11\ \text{mV}
  3. 110 mV110\ \text{mV}
  4. 17.6 mV17.6\ \text{mV}

Why are transformer cores laminated?

  1. to raise the permeability
  2. eddy-current loss grows as the square of the conducting thickness
  3. to reduce hysteresis loss to zero
  4. to lower the winding resistance