TExcelTAD
Home › Electromagnetic Theory: Maxwell's Equations to Waves › Reflection Coefficient, Standing Waves and VSWR

Reflection Coefficient, Standing Waves and VSWR

A transmitter's specification sheet says "VSWR ≤1.5\le 1.5", an antenna datasheet plots "return loss" in decibels, and a cable tester reports "reflection −20 dB-20\ \text{dB} at 12 m12\ \text{m}". All three measure one thing: how much of a wave travelling down a line comes back from the load because the load is not equal to the line's characteristic impedance. A mismatch wastes power, can overheat a transmitter's output stage with the returning wave, and creates standing waves whose voltage peaks can break down a cable's insulation. This lesson defines the reflection coefficient Γ\Gamma, shows the standing-wave pattern it creates, and connects the engineering numbers VSWR, return loss and mismatch loss.

The load reflection coefficient

Put the load at z=0z = 0 and measure distance back towards the source as d=−zd = -z. On the line (The Distributed Line) the voltage and current are a forward and a backward wave. At the load their sum must satisfy Ohm's law, V~(0)=ZLI~(0)\tilde{V}(0) = Z_L \tilde{I}(0):

V0++V0−=ZLZ0(V0+−V0−)⟹ΓL=V0−V0+=ZL−Z0ZL+Z0V_0^+ + V_0^- = \frac{Z_L}{Z_0}\left(V_0^+ - V_0^-\right) \quad\Longrightarrow\quad \Gamma_L = \frac{V_0^-}{V_0^+} = \frac{Z_L - Z_0}{Z_L + Z_0}

the same form as the plane-wave Γ\Gamma of Normal Incidence. ΓL\Gamma_L is complex in general, with ∣ΓL∣≤1\lvert\Gamma_L\rvert \le 1 for any passive load: 00 for a matched load, +1+1 for an open circuit, −1-1 for a short, and ∣ΓL∣=1\lvert\Gamma_L\rvert = 1 for any pure reactance. Moving a distance dd towards the source rotates it (lossless line):

Γ(d)=ΓL e−j2βd\Gamma(d) = \Gamma_L\, e^{-j2\beta d}

Standing waves

1.51.00.5 |V|/|V+| load VminVmax lambda/2 between maxima lambda/4 distance d from the load (towards the source, to the left)

The magnitude of the total voltage along the line is

∣V~(d)∣=∣V0+∣ ∣1+ΓLe−j2βd∣\lvert\tilde{V}(d)\rvert = \lvert V_0^+\rvert\, \bigl\lvert 1 + \Gamma_L e^{-j2\beta d} \bigr\rvert

It repeats every λ/2\lambda/2, between

Vmax=∣V0+∣(1+∣ΓL∣),Vmin=∣V0+∣(1−∣ΓL∣),VSWR=VmaxVmin=1+∣ΓL∣1−∣ΓL∣V_\text{max} = \lvert V_0^+\rvert(1 + \lvert\Gamma_L\rvert), \qquad V_\text{min} = \lvert V_0^+\rvert(1 - \lvert\Gamma_L\rvert), \qquad \text{VSWR} = \frac{V_\text{max}}{V_\text{min}} = \frac{1 + \lvert\Gamma_L\rvert}{1 - \lvert\Gamma_L\rvert}

with a maximum where Γ(d)\Gamma(d) is real and positive (dmax=θΓλ/(4π)d_\text{max} = \theta_\Gamma\lambda/(4\pi), plus multiples of λ/2\lambda/2) and a minimum a quarter wavelength away (dmin=(θΓ+π)λ/(4π)d_\text{min} = (\theta_\Gamma + \pi)\lambda/(4\pi)). The current pattern is the same shape shifted by λ/4\lambda/4: current maxima sit at voltage minima. Old "slotted line" measurements found an unknown load from exactly two readings, the VSWR and the position of the first minimum; The Smith Chart turns those two readings into ZLZ_L graphically.

Power and the decibel measures

The forward wave carries P+=∣V0+∣2/(2Z0)P^+ = \lvert V_0^+\rvert^2/(2Z_0) (peak phasors, Poynting's Theorem); the load absorbs what does not come back:

PL=P+(1−∣ΓL∣2)P_L = P^+\left(1 - \lvert\Gamma_L\rvert^2\right)
Measure Definition Matched ∣Γ∣=0.5\lvert\Gamma\rvert = 0.5
VSWR (1+∣Γ∣)/(1−∣Γ∣)(1 + \lvert\Gamma\rvert)/(1 - \lvert\Gamma\rvert) 11 3.03.0
return loss −20log⁡10∣Γ∣-20\log_{10}\lvert\Gamma\rvert (a positive number) ∞\infty 6.02 dB6.02\ \text{dB}
mismatch loss −10log⁡10(1−∣Γ∣2)-10\log_{10}(1 - \lvert\Gamma\rvert^2) 00 1.25 dB1.25\ \text{dB}

Many instruments plot S11=20log⁡10∣Γ∣S_{11} = 20\log_{10}\lvert\Gamma\rvert, which is minus the return loss. A VSWR of 1.51.5 (∣Γ∣=0.2\lvert\Gamma\rvert = 0.2, return loss 14 dB14\ \text{dB}) loses only 4 %4\ \% of the power: a modest mismatch costs little power; it matters more for the reflected wave's effect on the source and for ripple across frequency.

Worked example

Given: a 50 Ω50\ \Omega coax with velocity factor 0.6670.667 feeds a small antenna that presents ZL=25−j50 ΩZ_L = 25 - j50\ \Omega at 300 MHz300\ \text{MHz}.

Find: ΓL\Gamma_L, VSWR, return loss, the fraction of forward power delivered, and the distance from the load to the first voltage minimum.

Solve:

ΓL=(25−j50)−50(25−j50)+50=−25−j5075−j50=0.0769−j0.6154=0.6202∠−82.87∘VSWR=1.62020.3798=4.27,RL=−20log⁡100.6202=4.15 dB1−∣ΓL∣2=0.615  ⇒  61.5 % delivered (mismatch loss 2.11 dB)λ=0.667⋅2.998×108 m/s3×108 Hz=0.667 m,dmin=(−82.87∘+180∘)720∘λ=0.1349λ=8.99 cm\begin{aligned} \Gamma_L &= \frac{(25 - j50) - 50}{(25 - j50) + 50} = \frac{-25 - j50}{75 - j50} = 0.0769 - j0.6154 = 0.6202\angle{-82.87^\circ} \\ \text{VSWR} &= \frac{1.6202}{0.3798} = 4.27, \qquad RL = -20\log_{10}0.6202 = 4.15\ \text{dB} \\ 1 - \lvert\Gamma_L\rvert^2 &= 0.615 \;\Rightarrow\; 61.5\ \%\ \text{delivered (mismatch loss } 2.11\ \text{dB)} \\ \lambda &= \frac{0.667 \cdot 2.998 \times 10^8\ \text{m/s}}{3 \times 10^8\ \text{Hz}} = 0.667\ \text{m}, \qquad d_\text{min} = \frac{(-82.87^\circ + 180^\circ)}{720^\circ}\lambda = 0.1349\lambda = 8.99\ \text{cm} \end{aligned}

Check: a capacitive load (X<0X < 0) has θΓ\theta_\Gamma between −180∘-180^\circ and 00, so the first minimum is less than λ/4\lambda/4 from it, as found. An inductive load would put a maximum first.

In Python, with scikit-rf

NumPy for the pattern, then skrf for the same numbers through its network objects. skrf describes a one-port by its reflection coefficient S11S_{11}; the media object builds ideal lines and loads.

python · try it yourself
import numpy as np
import matplotlib.pyplot as plt
import skrf as rf

z0, zl, f, vf = 50.0, 25 - 50j, 300e6, 0.667
lam = vf * 2.998e8 / f
g = (zl - z0) / (zl + z0)
m, th = abs(g), np.angle(g)
print(f"Gamma_L = {g.real:.4f}{g.imag:+.4f}j = {m:.4f} at {np.degrees(th):.2f} deg")
print(f"VSWR = {(1+m)/(1-m):.3f}, return loss = {-20*np.log10(m):.2f} dB, "
      f"mismatch loss = {-10*np.log10(1-m*m):.2f} dB")
d_min = (th + np.pi) / (4 * np.pi) * lam
print(f"first voltage minimum {d_min*100:.2f} cm from the load, maxima every {lam/2*100:.2f} cm")

# the same with scikit-rf: a load on an ideal line of the same velocity
freq = rf.Frequency(300, 300, 1, unit="MHz")
line = rf.media.DefinedGammaZ0(frequency=freq, z0=50, gamma=1j * 2 * np.pi * f / (vf * 2.998e8))
load = line.load(rf.zl_2_Gamma0(50, zl))
print(f"skrf: |S11| = {float(np.abs(load.s[0, 0, 0])):.4f}, VSWR = {float(load.s_vswr[0, 0, 0]):.3f}, "
      f"S11 = {float(load.s_db[0, 0, 0]):.2f} dB")
moved = line.line(d_min, unit="m") ** load      # look into the line at the first minimum
zin = moved.z[0, 0, 0]
print(f"impedance seen at the minimum: {zin.real:.2f}{round(zin.imag, 2) + 0.0:+.2f}j Ohm (Z0/VSWR = {z0*(1-m)/(1+m):.2f})")

d = np.linspace(0, lam, 400)
v = np.abs(1 + g * np.exp(-2j * 2 * np.pi / lam * d))
plt.figure(figsize=(6, 2.8))
plt.plot(d * 100, v)
plt.gca().invert_xaxis()
plt.xlabel("distance from the load d (cm)"); plt.ylabel("|V| / |V+|")
plt.title("Standing wave, ZL = 25 - j50 Ohm on 50 Ohm"); plt.tight_layout()
plt.show()
Gamma_L = 0.0769-0.6154j = 0.6202 at -82.87 deg
VSWR = 4.266, return loss = 4.15 dB, mismatch loss = 2.11 dB
first voltage minimum 8.99 cm from the load, maxima every 33.33 cm
skrf: |S11| = 0.6202, VSWR = 4.266, S11 = -4.15 dB
impedance seen at the minimum: 11.72+0.00j Ohm (Z0/VSWR = 11.72)

At a voltage minimum the impedance looking towards the load is real and equal to Z0/VSWRZ_0/\text{VSWR} (at a maximum, Z0⋅VSWRZ_0 \cdot \text{VSWR}). That fact is the basis of the single-stub match in The Smith Chart and of quarter-wave matching of complex loads.

Interactive: reflections you can see

The ee-transmission-line lab shows a step on a line, but its readouts also give the sinusoidal measures for the chosen load. With Rs=Z0=50 ΩR_s = Z_0 = 50\ \Omega and RL=150 ΩR_L = 150\ \Omega it reads ΓL=0.5000\Gamma_L = 0.5000, VSWR 3.0003.000 and return loss 6.02 dB6.02\ \text{dB}, the right-hand column of the table; the launched 2.5 V2.5\ \text{V} wave returns as a 1.25 V1.25\ \text{V} step (the frame shows it halfway back) and the line settles at 3.75 V3.75\ \text{V}. Try RL=50 ΩR_L = 50\ \Omega (no reflection), RL=15 ΩR_L = 15\ \Omega (the slider's nearest step to 16.7 Ω16.7\ \Omega, which would give Γ=−0.5\Gamma = -0.5: it reads ΓL=−0.5385\Gamma_L = -0.5385, almost the same VSWR with the opposite sign) and the open and short terminations.

024source endload endv(x) (V)t = 1.50 Td = 1.50 nsS5.0 VRs 50.0 OhmZ0 = 50.0 Ohm, one-way delay Td = 1.00 nsRL 150 Ohm0 Td2 Td4 Td6 Td8 TdGS = 0.000GL = 0.5002.5001.25002402468t (Td)v at source endv at load end

Guided lab: return loss of resistor loads

Hand calculation. On a 50 Ω50\ \Omega system: a 100 Ω100\ \Omega load gives Γ=1/3\Gamma = 1/3, VSWR 2.02.0, return loss 9.54 dB9.54\ \text{dB}; 75 Ω75\ \Omega gives 0.20.2, 1.51.5, 13.98 dB13.98\ \text{dB}; 47 Ω47\ \Omega (E12 value) gives −0.031-0.031, 1.061.06, 30.2 dB30.2\ \text{dB}.

Simulation. The script with zl set to each value; the lab with RLR_L set to each value.

What you would measure. Solder leaded or SMD resistors directly across an SMA connector (shortest possible leads) and measure S11S_{11} from 11 to 500 MHz500\ \text{MHz} with a calibrated VNA or a return-loss bridge and spectrum analyser. Expect the predicted return loss within about 0.5 dB0.5\ \text{dB} at the low end (resistor tolerance: a 1 %1\ \% 100 Ω100\ \Omega part moves Γ\Gamma by about ±0.004\pm 0.004). Higher up the readings drift: lead inductance (roughly 1 nH/mm1\ \text{nH/mm}) and the resistor's capacitance turn the "resistor" into a complex load, which is the point where a field model of the part takes over from its circuit value.

Hazards and safe setup. VNA test levels are milliwatts. Avoid electrostatic discharge into the VNA ports (touch the connector shell first), never feed DC into them, and use a torque wrench on SMA connectors.

Pitfalls

  • Return loss sign. Return loss is positive in decibels; S11S_{11} in decibels is negative. "Return loss of −20 dB-20\ \text{dB}" is a common but sloppy way of saying S11=−20 dBS_{11} = -20\ \text{dB}.
  • VSWR hides the phase. Very different loads (100 Ω100\ \Omega and 25 Ω25\ \Omega on 50 Ω50\ \Omega) have the same VSWR.
  • Losses flatter a bad match. A long lossy cable attenuates the reflected wave twice, so a bad antenna can look well matched from the transmitter end.
  • Γ\Gamma uses the line's Z0Z_0, not 50 Ω50\ \Omega by habit: the same load reflects differently on a 75 Ω75\ \Omega line.

Practice

  1. A 75 Ω75\ \Omega line ends in ZL=75+j75 ΩZ_L = 75 + j75\ \Omega. Find ∣ΓL∣\lvert\Gamma_L\rvert and the VSWR.
  2. A transmitter specifies return loss ≥10 dB\ge 10\ \text{dB}. What maximum VSWR and what maximum fraction of reflected power does that allow?
  3. At a voltage minimum on a 50 Ω50\ \Omega line with VSWR 2.52.5, what impedance looks towards the load?
Answer
  1. ΓL=j75/(150+j75)=0.447∠63.4∘\Gamma_L = j75/(150 + j75) = 0.447\angle 63.4^\circ, VSWR =2.62= 2.62.
  2. ∣Γ∣≤0.316\lvert\Gamma\rvert \le 0.316, VSWR ≤1.92\le 1.92, reflected power ≤10 %\le 10\ \%.
  3. 50/2.5=20 Ω50/2.5 = 20\ \Omega, purely resistive.

Test yourself

A 50 Ω50\ \Omega line ends in 150 Ω150\ \Omega. The VSWR is…

  1. 1.51.5
  2. 2.02.0
  3. 3.03.0
  4. 0.50.5

Which quantity is −20log⁡10∣Γ∣-20\log_{10}\lvert\Gamma\rvert?

  1. mismatch loss
  2. return loss
  3. insertion loss
  4. VSWR in dB

Successive voltage minima of a standing wave are separated by…

  1. λ/4\lambda/4
  2. λ/2\lambda/2
  3. λ\lambda
  4. it depends on Γ\Gamma

What fraction of the forward power reaches a load with ∣Γ∣=0.2\lvert\Gamma\rvert = 0.2?

  1. 80 %80\ \%
  2. 96 %96\ \%
  3. 64 %64\ \%
  4. 98 %98\ \%