Reflection Coefficient, Standing Waves and VSWR
A transmitter's specification sheet says "VSWR ", an antenna datasheet plots "return loss" in decibels, and a cable tester reports "reflection at ". All three measure one thing: how much of a wave travelling down a line comes back from the load because the load is not equal to the line's characteristic impedance. A mismatch wastes power, can overheat a transmitter's output stage with the returning wave, and creates standing waves whose voltage peaks can break down a cable's insulation. This lesson defines the reflection coefficient , shows the standing-wave pattern it creates, and connects the engineering numbers VSWR, return loss and mismatch loss.
The load reflection coefficient
Put the load at and measure distance back towards the source as . On the line (The Distributed Line) the voltage and current are a forward and a backward wave. At the load their sum must satisfy Ohm's law, :
the same form as the plane-wave of Normal Incidence. is complex in general, with for any passive load: for a matched load, for an open circuit, for a short, and for any pure reactance. Moving a distance towards the source rotates it (lossless line):
Standing waves
The magnitude of the total voltage along the line is
It repeats every , between
with a maximum where is real and positive (, plus multiples of ) and a minimum a quarter wavelength away (). The current pattern is the same shape shifted by : current maxima sit at voltage minima. Old "slotted line" measurements found an unknown load from exactly two readings, the VSWR and the position of the first minimum; The Smith Chart turns those two readings into graphically.
Power and the decibel measures
The forward wave carries (peak phasors, Poynting's Theorem); the load absorbs what does not come back:
| Measure | Definition | Matched | |
|---|---|---|---|
| VSWR | |||
| return loss | (a positive number) | ||
| mismatch loss |
Many instruments plot , which is minus the return loss. A VSWR of (, return loss ) loses only of the power: a modest mismatch costs little power; it matters more for the reflected wave's effect on the source and for ripple across frequency.
Worked example
Given: a coax with velocity factor feeds a small antenna that presents at .
Find: , VSWR, return loss, the fraction of forward power delivered, and the distance from the load to the first voltage minimum.
Solve:
Check: a capacitive load () has between and , so the first minimum is less than from it, as found. An inductive load would put a maximum first.
In Python, with scikit-rf
NumPy for the pattern, then skrf for the same numbers through its network objects. skrf describes a one-port by its reflection coefficient ; the media object builds ideal lines and loads.
import numpy as np
import matplotlib.pyplot as plt
import skrf as rf
z0, zl, f, vf = 50.0, 25 - 50j, 300e6, 0.667
lam = vf * 2.998e8 / f
g = (zl - z0) / (zl + z0)
m, th = abs(g), np.angle(g)
print(f"Gamma_L = {g.real:.4f}{g.imag:+.4f}j = {m:.4f} at {np.degrees(th):.2f} deg")
print(f"VSWR = {(1+m)/(1-m):.3f}, return loss = {-20*np.log10(m):.2f} dB, "
f"mismatch loss = {-10*np.log10(1-m*m):.2f} dB")
d_min = (th + np.pi) / (4 * np.pi) * lam
print(f"first voltage minimum {d_min*100:.2f} cm from the load, maxima every {lam/2*100:.2f} cm")
# the same with scikit-rf: a load on an ideal line of the same velocity
freq = rf.Frequency(300, 300, 1, unit="MHz")
line = rf.media.DefinedGammaZ0(frequency=freq, z0=50, gamma=1j * 2 * np.pi * f / (vf * 2.998e8))
load = line.load(rf.zl_2_Gamma0(50, zl))
print(f"skrf: |S11| = {float(np.abs(load.s[0, 0, 0])):.4f}, VSWR = {float(load.s_vswr[0, 0, 0]):.3f}, "
f"S11 = {float(load.s_db[0, 0, 0]):.2f} dB")
moved = line.line(d_min, unit="m") ** load # look into the line at the first minimum
zin = moved.z[0, 0, 0]
print(f"impedance seen at the minimum: {zin.real:.2f}{round(zin.imag, 2) + 0.0:+.2f}j Ohm (Z0/VSWR = {z0*(1-m)/(1+m):.2f})")
d = np.linspace(0, lam, 400)
v = np.abs(1 + g * np.exp(-2j * 2 * np.pi / lam * d))
plt.figure(figsize=(6, 2.8))
plt.plot(d * 100, v)
plt.gca().invert_xaxis()
plt.xlabel("distance from the load d (cm)"); plt.ylabel("|V| / |V+|")
plt.title("Standing wave, ZL = 25 - j50 Ohm on 50 Ohm"); plt.tight_layout()
plt.show()Gamma_L = 0.0769-0.6154j = 0.6202 at -82.87 deg
VSWR = 4.266, return loss = 4.15 dB, mismatch loss = 2.11 dB
first voltage minimum 8.99 cm from the load, maxima every 33.33 cm
skrf: |S11| = 0.6202, VSWR = 4.266, S11 = -4.15 dB
impedance seen at the minimum: 11.72+0.00j Ohm (Z0/VSWR = 11.72)
At a voltage minimum the impedance looking towards the load is real and equal to (at a maximum, ). That fact is the basis of the single-stub match in The Smith Chart and of quarter-wave matching of complex loads.
Interactive: reflections you can see
The ee-transmission-line lab shows a step on a line, but its readouts also give the sinusoidal measures for the chosen load. With and it reads , VSWR and return loss , the right-hand column of the table; the launched wave returns as a step (the frame shows it halfway back) and the line settles at . Try (no reflection), (the slider's nearest step to , which would give : it reads , almost the same VSWR with the opposite sign) and the open and short terminations.
Guided lab: return loss of resistor loads
Hand calculation. On a system: a load gives , VSWR , return loss ; gives , , ; (E12 value) gives , , .
Simulation. The script with zl set to each value; the lab with set to each value.
What you would measure. Solder leaded or SMD resistors directly across an SMA connector (shortest possible leads) and measure from to with a calibrated VNA or a return-loss bridge and spectrum analyser. Expect the predicted return loss within about at the low end (resistor tolerance: a part moves by about ). Higher up the readings drift: lead inductance (roughly ) and the resistor's capacitance turn the "resistor" into a complex load, which is the point where a field model of the part takes over from its circuit value.
Hazards and safe setup. VNA test levels are milliwatts. Avoid electrostatic discharge into the VNA ports (touch the connector shell first), never feed DC into them, and use a torque wrench on SMA connectors.
Pitfalls
- Return loss sign. Return loss is positive in decibels; in decibels is negative. "Return loss of " is a common but sloppy way of saying .
- VSWR hides the phase. Very different loads ( and on ) have the same VSWR.
- Losses flatter a bad match. A long lossy cable attenuates the reflected wave twice, so a bad antenna can look well matched from the transmitter end.
- uses the line's , not by habit: the same load reflects differently on a line.
Practice
- A line ends in . Find and the VSWR.
- A transmitter specifies return loss . What maximum VSWR and what maximum fraction of reflected power does that allow?
- At a voltage minimum on a line with VSWR , what impedance looks towards the load?
Answer
- , VSWR .
- , VSWR , reflected power .
- , purely resistive.
Test yourself
A line ends in . The VSWR is…
Which quantity is ?
- mismatch loss
- return loss
- insertion loss
- VSWR in dB
Successive voltage minima of a standing wave are separated by…
- it depends on
What fraction of the forward power reaches a load with ?