TExcelTAD
Home › Electromagnetic Theory: Maxwell's Equations to Waves › Magnetic Materials, Permeability and Hysteresis

Magnetic Materials, Permeability and Hysteresis

Wind 20 turns on an air former and you get about a microhenry; wind the same 20 turns on a ferrite toroid and you get a millihenry. Put a steel core in a transformer and it gets warm even with nothing connected. Lift a few grams of neodymium and it holds a kilogram of steel. All three are the material's own atomic currents adding to, or fighting, the field of the coil. This lesson models them with the magnetisation M\mathbf{M}, defines permeability properly, and explains hysteresis, the loop that makes permanent magnets possible and costs energy in every AC core. The school picture of magnets is in Magnetic Field and the circuit view of cores in Magnetism and Induction.

Magnetisation, H and B

Each atom carries a tiny magnetic moment from electron spin and orbital motion. In a field these moments partly line up, and the material acquires a magnetisation M\mathbf{M}, the magnetic moment per unit volume (A/m). An aligned block of moments acts like a current flowing around its surface (a bound current Kb=M×n^\mathbf{K}_b = \mathbf{M} \times \hat{\mathbf{n}}), which adds to the field. The general relation is

B=μ0(H+M)\mathbf{B} = \mu_0(\mathbf{H} + \mathbf{M})

and Ampère's law for H\mathbf{H} (Ampère's Circuital Law: H and B) counts only the free currents in your wires. In a linear material M=χmH\mathbf{M} = \chi_m\mathbf{H} with the susceptibility χm\chi_m, so

B=μ0(1+χm)H=μrμ0H=μH\mathbf{B} = \mu_0(1 + \chi_m)\mathbf{H} = \mu_r\mu_0\mathbf{H} = \mu\mathbf{H}

Three kinds of response

Class χm\chi_m Mechanism Examples
diamagnetic about −10−5-10^{-5} induced orbital currents oppose the field copper, water, bismuth, superconductors (χm=−1\chi_m = -1)
paramagnetic 10−610^{-6} to 10−310^{-3} weak alignment of atomic moments, fought by thermal motion aluminium, oxygen, platinum
ferromagnetic / ferrimagnetic 10210^2 to 10510^5, field dependent moments aligned in domains; the field moves domain walls and rotates domains iron, nickel, cobalt, steels, ferrites

For dia- and paramagnets μr=1\mu_r = 1 for every engineering purpose. Ferromagnets are where the action is, and for them μr\mu_r is not a constant: it depends on HH, on the history of the material, on temperature and on frequency. Above the Curie temperature the domains vanish and the material becomes paramagnetic (iron at about 770 ∘C770\,^\circ\text{C}; manganese-zinc power ferrites at only about 200200 to 250 ∘C250\,^\circ\text{C}, and high-permeability grades lower still, a real limit for hot power inductors).

The hysteresis loop

HB Bsat +Br -Br +Hc -Hc rising H (lower branch) falling H (upper branch) loop area = energy lost per cycle per m^3

Drive a ferromagnet with a coil current that goes up and down, and BB does not retrace its path. Starting from a demagnetised state, BB climbs steeply and then saturates at BsatB_\text{sat} when all domains are aligned (beyond that BB grows only as μ0H\mu_0 H). Reduce HH to zero and BB stays at the remanence BrB_r; it takes a reverse field, the coercivity HcH_c, to bring BB back to zero. The closed curve is the hysteresis loop.

  • Soft materials (silicon steel, ferrites, nanocrystalline and amorphous alloys) have a narrow loop: small HcH_c, high permeability, low loss per cycle. They go into transformers, inductors, motors and shields.
  • Hard materials (NdFeB, SmCo, hard ferrite, AlNiCo) have a wide loop: large HcH_c, high BrB_r. A large coercivity is exactly what lets a magnet keep its magnetisation against its own demagnetising field: permanent magnets.

Hysteresis loss. The energy the coil delivers per unit volume while BB changes is ∫H dB\int H\,dB. Around a closed loop the stored part comes back, and the loop area is lost as heat each cycle:

wh=∮H dB(J/m3 per cycle),ph=f whw_h = \oint H\,dB \quad (\text{J/m}^3 \text{ per cycle}), \qquad p_h = f\,w_h

So hysteresis loss rises in proportion to frequency at a fixed flux swing. Add the eddy-current loss (currents induced in the conducting core, rising with f2f^2; reduced by thin insulated laminations or by non-conducting ferrite; Faraday's and Lenz's Laws) and you get the core loss in datasheets. Designers fit it with the empirical Steinmetz equation p=kfαB^βp = k f^\alpha \hat{B}^\beta, with α\alpha typically 11 to 22 and β\beta typically 22 to 33 over a fitted range.

Typical materials (handbook ranges as of 2026; every grade's datasheet differs):

Material Typical μr\mu_r BsatB_\text{sat} or BrB_r Used for
silicon steel (about 3 % Si) 10310^3 to several 10410^4 (grain-oriented highest) Bsat≈2.0 TB_\text{sat} \approx 2.0\ \text{T} 50/60 Hz transformers, motors
MnZn ferrite 10310^3 to 10410^4 Bsat≈0.4B_\text{sat} \approx 0.4 to 0.5 T0.5\ \text{T} at 25 ∘C25\,^\circ\text{C}, lower when hot switch-mode transformers, 10 kHz to 1 MHz
NiZn ferrite 1010 to 10310^3 about 0.3 T0.3\ \text{T} EMI beads, RF up to hundreds of MHz
iron powder, alloy powder 1010 to 100100 (distributed gap) about 11 to 1.5 T1.5\ \text{T} power inductors with DC bias
NdFeB magnet recoil μr≈1.05\mu_r \approx 1.05 Br≈1.2B_r \approx 1.2 to 1.45 T1.45\ \text{T} motors, speakers, sensors
hard ferrite magnet recoil μr≈1.1\mu_r \approx 1.1 Br≈0.4 TB_r \approx 0.4\ \text{T} cheap motors, fridge magnets

Worked example: hysteresis loss in a steel core

Given: a steel modelled by the loop in the figure: BsatB_\text{sat} term 1.5 T1.5\ \text{T}, Hc=40 A/mH_c = 40\ \text{A/m}, cycled between ±500 A/m\pm 500\ \text{A/m} at 50 Hz50\ \text{Hz}. Density 7650 kg/m37650\ \text{kg/m}^3. A core of 2 kg2\ \text{kg}.

Find: an estimate of the loss per cycle, per kilogram and for the core.

Solve: a loop that is nearly rectangular between ±Bsat\pm B_\text{sat} and ±Hc\pm H_c has area about 4BsatHc4B_\text{sat}H_c:

wh≈4⋅1.5 T⋅40 A/m=240 J/m3ph=fwh=50 Hz⋅240 J/m3=12.0 kW/m3=12 0007650 W/kg=1.57 W/kgP=2 kg⋅1.57 W/kg=3.1 W\begin{aligned} w_h &\approx 4 \cdot 1.5\ \text{T} \cdot 40\ \text{A/m} = 240\ \text{J/m}^3 \\ p_h &= f w_h = 50\ \text{Hz} \cdot 240\ \text{J/m}^3 = 12.0\ \text{kW/m}^3 = \frac{12\,000}{7650}\ \text{W/kg} = 1.57\ \text{W/kg} \\ P &= 2\ \text{kg} \cdot 1.57\ \text{W/kg} = 3.1\ \text{W} \end{aligned}

Check: unit check, T⋅A/m=J/m3\text{T} \cdot \text{A/m} = \text{J/m}^3. Electrical steels are sold by their total loss at 1.5 T1.5\ \text{T}, 50 Hz50\ \text{Hz}: roughly 22 to 10 W/kg10\ \text{W/kg} for non-oriented grades depending on grade and thickness (the grade name carries it: an M400-50A sheet is 4.00 W/kg4.00\ \text{W/kg} at most, IEC 60404-8-4), and grain-oriented steel is far lower, so the estimate is in the right range. A transformer's no-load loss is this core loss, paid all day whether or not anything is connected.

In Python: a model loop and its area

The code uses a simple two-branch model, B=Bstanh⁡((H∓Hc)/H0)+μ0HB = B_s\tanh((H \mp H_c)/H_0) + \mu_0 H (a fitted curve, not a physical theory such as Jiles–Atherton or Preisach), integrates the loop area, and reads the permeabilities off the curve.

python · try it yourself
import numpy as np
import matplotlib.pyplot as plt
MU0 = 4e-7 * np.pi
Bs, Hc, H0 = 1.5, 40.0, 100.0          # model parameters: saturation term (T), coercivity (A/m), knee width (A/m)
Hmax, f, dens = 500.0, 50.0, 7650.0    # peak field (A/m), frequency (Hz), steel density (kg/m^3)

H = np.linspace(-Hmax, Hmax, 4001)
B_up = Bs * np.tanh((H - Hc) / H0) + MU0 * H      # rising branch
B_dn = Bs * np.tanh((H + Hc) / H0) + MU0 * H      # falling branch
Br = Bs * np.tanh(Hc / H0)
print(f"remanence Br = {Br:.3f} T, coercivity Hc = {Hc:.0f} A/m, B at Hmax = {B_up[-1]:.3f} T")

trap = lambda y, x: float(np.sum((y[1:] + y[:-1]) * np.diff(x)) / 2)
w = abs(trap(H, B_dn) - trap(H, B_up))           # loop area = closed integral of H dB
print(f"loop area = {w:.1f} J/m^3 per cycle")
print(f"hysteresis loss at {f:.0f} Hz: {w*f/1e3:.2f} kW/m^3 = {w*f/dens:.2f} W/kg")

dBdH = np.gradient(B_up, H)
i = np.argmax(dBdH)
print(f"steepest slope at H = {H[i]:.1f} A/m: mu_r(diff) = {dBdH[i]/MU0:.0f}")
k = np.argmin(abs(H - 200))
print(f"amplitude permeability at 200 A/m: B/(mu0 H) = {B_up[k]/(MU0*H[k]):.0f}")

fig, ax = plt.subplots(figsize=(5, 3.6))
ax.plot(H, B_up, label="rising H")
ax.plot(H, B_dn, label="falling H")
ax.set_xlabel("H (A/m)"); ax.set_ylabel("B (T)"); ax.grid(True, alpha=0.3); ax.legend()
ax.set_title("Model hysteresis loop")
plt.show()
remanence Br = 0.570 T, coercivity Hc = 40 A/m, B at Hmax = 1.500 T
loop area = 239.7 J/m^3 per cycle
hysteresis loss at 50 Hz: 11.99 kW/m^3 = 1.57 W/kg
steepest slope at H = 40.0 A/m: mu_r(diff) = 11938
amplitude permeability at 200 A/m: B/(mu0 H) = 5502

The integrated area agrees with the rectangle estimate to 0.1 %. Note how many "permeabilities" one material has: about 12 000 on the steep part, 5500 as B/(μ0H)B/(\mu_0 H) at 200 A/m200\ \text{A/m}, and almost 1 in saturation. Datasheets therefore quote the initial, the maximum and the amplitude permeability separately, and an inductor whose core saturates loses most of its inductance (Inductance of Common Geometries and Magnetic Energy).

Guided lab: display a ferrite's B-H loop

Hand calculation. A ferrite toroid with effective path length ℓe=50 mm\ell_e = 50\ \text{mm} and area Ae=20 mm2A_e = 20\ \text{mm}^2, N1=N2=20N_1 = N_2 = 20 turns. With I1I_1 in the primary, H=N1I1/ℓeH = N_1 I_1/\ell_e: 100 mA100\ \text{mA} gives 40 A/m40\ \text{A/m}, enough to drive a high-permeability ferrite towards saturation. The secondary voltage is N2Ae dB/dtN_2 A_e\,dB/dt; an RC integrator (R=10 kΩR = 10\ \text{k}\Omega, C=1 μFC = 1\ \mu\text{F}, RC≫1/fRC \gg 1/f) gives vC=N2AeB/(RC)v_C = N_2 A_e B/(RC), so B=vC RC/(N2Ae)=vC⋅25 T/VB = v_C\,RC/(N_2 A_e) = v_C \cdot 25\ \text{T/V} for these values.

Simulation. Adapt the model above: choose HcH_c and BsB_s from the ferrite's datasheet (typically HcH_c around 1010 to 20 A/m20\ \text{A/m}, BsB_s near 0.4 T0.4\ \text{T}) and predict the loop.

What you would measure. Drive the primary from a function generator at 1 kHz1\ \text{kHz} through a 10 Ω10\ \Omega sense resistor; channel X of the oscilloscope across the resistor (proportional to HH), channel Y across the integrator capacitor (proportional to BB), XY mode. You should see a loop that flattens at the ends; raise the amplitude to watch it saturate, lower it to see a thin ellipse (the Rayleigh region). Expect HcH_c and BsatB_\text{sat} within ±20 %\pm 20\ \% of the datasheet: the effective dimensions are approximations, the integrator droops, and ferrite properties change strongly with temperature. If the generator cannot supply enough current (its 50 Ω50\ \Omega output limits it), add primary turns.

Hazards and safe setup. Signal-generator levels only (a few volts). Keep the oscilloscope grounds on the same side (both on the circuit's common), or one channel shorts the sense resistor through the ground leads (Probes).

Pitfalls

  • Treating μr\mu_r as a constant. Fine for small signals around a fixed point; wrong near saturation, with DC bias, or over temperature.
  • Ignoring remanence. A core left magnetised (after a DC pulse or an interrupted transformer) can saturate on the next switch-on: transformer inrush current.
  • Ferrite saturates early. About 0.4 T0.4\ \text{T} at room temperature and less when hot, against about 2 T2\ \text{T} for steel.
  • Mixing up BrB_r and HcH_c for magnets. A magnet's useful field depends on both and on its shape (the demagnetising field); remanence alone does not say how strong a magnet is in use.

Practice

  1. A material has χm=2999\chi_m = 2999. What is μr\mu_r, and what BB does H=50 A/mH = 50\ \text{A/m} give if it stays linear?
  2. With H=1000 A/mH = 1000\ \text{A/m} and B=1.2 TB = 1.2\ \text{T} in a steel, find MM.
  3. A ferrite core's loop area is 30 J/m330\ \text{J/m}^3 at a given flux swing. What is the hysteresis loss at 100 kHz100\ \text{kHz} in a core of 1 cm31\ \text{cm}^3?
Answer
  1. μr=3000\mu_r = 3000; B=3000⋅4π×10−7⋅50=0.188 TB = 3000 \cdot 4\pi \times 10^{-7} \cdot 50 = 0.188\ \text{T}.
  2. M=B/μ0−H=1.2/(4π×10−7)−1000=9.54×105 A/mM = B/\mu_0 - H = 1.2/(4\pi \times 10^{-7}) - 1000 = 9.54 \times 10^5\ \text{A/m}.
  3. 30⋅105=3×106 W/m330 \cdot 10^5 = 3 \times 10^6\ \text{W/m}^3; times 10−6 m310^{-6}\ \text{m}^3 = 3 W3\ \text{W}.

Test yourself

The general relation between B, H and M is…

  1. B=μ0H−M\mathbf{B} = \mu_0\mathbf{H} - \mathbf{M}
  2. B=μ0(H+M)\mathbf{B} = \mu_0(\mathbf{H} + \mathbf{M})
  3. H=μ0(B+M)\mathbf{H} = \mu_0(\mathbf{B} + \mathbf{M})
  4. M=μ0B\mathbf{M} = \mu_0\mathbf{B}

The area of a B-H loop equals…

  1. the stored energy
  2. the energy lost per cycle per unit volume
  3. the permeability
  4. the remanence times the saturation

A material for a permanent magnet should have…

  1. low HcH_c, low BrB_r
  2. high HcH_c, high BrB_r
  3. high μr\mu_r and a thin loop
  4. χm<0\chi_m < 0

Hysteresis loss at a fixed flux swing grows with frequency as…

  1. f0f^0
  2. ff
  3. f2f^2
  4. 1/f1/f

Which core material saturates at the lowest flux density?

  1. silicon steel
  2. MnZn ferrite
  3. air
  4. iron powder