TExcelTAD
Home › Lab Skills: Measurement, Uncertainty & Graphs › Absolute, Relative and Percentage Uncertainty

Absolute, Relative and Percentage Uncertainty

A question to start

Which measurement is better: the length of a classroom, (8.40±0.01) m(8.40 \pm 0.01)\ \text{m}, or the thickness of a coin, (2.0±0.5) mm(2.0 \pm 0.5)\ \text{mm}? The coin's uncertainty is far smaller in millimetres. But compared with what was measured, the coin is the poor one: half a millimetre is a quarter of its thickness. To compare, you need the uncertainty as a fraction of the value.

The idea

Quantity Symbol Formula Unit
absolute uncertainty (sai số tuyệt đối) Δx\Delta x from the readings same as xx
relative (fractional) uncertainty (sai số tỉ đối) δx\delta x Δxx\frac{\Delta x}{x} none
percentage uncertainty Δxx×100%\frac{\Delta x}{x} \times 100\% %\%
δx=Δxx,percentage uncertainty=Δxx×100%\delta x = \frac{\Delta x}{x}, \qquad \text{percentage uncertainty} = \frac{\Delta x}{x} \times 100\%

Here xx is the best value (usually the mean). The relative uncertainty has no unit: the units cancel. That is why it can compare a length with a time or a mass.

For the two examples: classroom 0.018.40=0.0012=0.12%\frac{0.01}{8.40} = 0.0012 = 0.12\%; coin 0.52.0=0.25=25%\frac{0.5}{2.0} = 0.25 = 25\%. The classroom measurement is about 200 times more precise.

Going back is just as easy: Δx=δx×x\Delta x = \delta x \times x. A 47 Ω47\ \Omega resistor marked "±5%\pm 5\%" has ΔR=0.05×47 Ω=2.35 Ω≈2 Ω\Delta R = 0.05 \times 47\ \Omega = 2.35\ \Omega \approx 2\ \Omega.

Worked examples

Example 1: one result, three ways. Given: L=(64±1) mmL = (64 \pm 1)\ \text{mm}. Find: the relative and percentage uncertainty. Solve: δL=1 mm64 mm=0.0156\delta L = \frac{1\ \text{mm}}{64\ \text{mm}} = 0.0156; percentage =1.6%= 1.6\%. Answer: L=64 mm±1.6%L = 64\ \text{mm} \pm 1.6\%. Check: the units cancelled; give percentages to 1 or 2 significant figures.

Example 2: choosing an instrument. Given: a coin about 2 mm2\ \text{mm} thick, measured with a ruler (±0.5 mm\pm 0.5\ \text{mm}), a vernier caliper (±0.05 mm\pm 0.05\ \text{mm}) or a micrometer (±0.005 mm\pm 0.005\ \text{mm}). The caliper reads 1.95 mm1.95\ \text{mm}. Find: the percentage uncertainty for each. Solve:

Instrument Result Percentage uncertainty
ruler (2.0±0.5) mm(2.0 \pm 0.5)\ \text{mm} 0.52.0×100%=25%\frac{0.5}{2.0} \times 100\% = 25\%
vernier caliper (1.95±0.05) mm(1.95 \pm 0.05)\ \text{mm} 0.051.95×100%=2.6%\frac{0.05}{1.95} \times 100\% = 2.6\%
micrometer (1.950±0.005) mm(1.950 \pm 0.005)\ \text{mm} 0.0051.950×100%=0.26%\frac{0.005}{1.950} \times 100\% = 0.26\%

Answer: each instrument is ten times better than the one before. Check: a 2 mm2\ \text{mm} object needs at least a caliper for a percentage uncertainty below about 5%5\%.

Example 3: comparing with an accepted value. Given: a class measures g=(9.6±0.3) m/s2g = (9.6 \pm 0.3)\ \text{m/s}^2; the accepted value is 9.8 m/s29.8\ \text{m/s}^2. Find: the percentage uncertainty, the percentage difference from the accepted value, and whether they agree. Formula:

percentage difference=∣measured−accepted∣accepted×100%\text{percentage difference} = \frac{\lvert \text{measured} - \text{accepted} \rvert}{\text{accepted}} \times 100\%

Solve: percentage uncertainty =0.39.6×100%=3.1%= \frac{0.3}{9.6} \times 100\% = 3.1\%. Percentage difference =∣9.6−9.8∣9.8×100%=2.0%= \frac{\lvert 9.6 - 9.8 \rvert}{9.8} \times 100\% = 2.0\%. The range of the result is 9.39.3 to 9.9 m/s29.9\ \text{m/s}^2, and 9.89.8 lies inside it. Answer: the result agrees with the accepted value within its uncertainty. Check: if the difference were much bigger than the uncertainty, you would look for a systematic error.

Making the percentage uncertainty small

The reading uncertainty of an instrument is fixed, so the percentage uncertainty is smaller when the measured quantity is bigger:

  • time 20 swings, not 1 (the timing doubt stays the same, the time is 20 times longer);
  • measure the thickness of 100 sheets of paper, not 1;
  • choose a meter range where the pointer moves near full scale;
  • in a temperature-change experiment, heat long enough for a large change.

Try it: the percentage game

With a 30 cm30\ \text{cm} ruler, measure (a) the length of a pencil, (b) the width of an eraser, (c) the thickness of a phone. Use ±1 mm\pm 1\ \text{mm} for each length (two readings). Work out the three percentage uncertainties. Which measurement would you improve with a caliper, and why?

Common mistakes

  • Giving a relative uncertainty a unit, or a percentage with no %\% sign.
  • Dividing by the uncertainty instead of by the value: it is Δxx\frac{\Delta x}{x}, not xΔx\frac{x}{\Delta x}.
  • Confusing percentage uncertainty with percentage difference. The first comes from your readings; the second compares with a known value.
  • Saying a result is wrong because it is not exactly the accepted value. Check whether the accepted value lies within your uncertainty.
  • Too many figures: ±1.5625%\pm 1.5625\% should be ±1.6%\pm 1.6\%.

Practice

  1. Find the percentage uncertainty of (a) t=(16.4±0.1) st = (16.4 \pm 0.1)\ \text{s}; (b) m=(250±1) gm = (250 \pm 1)\ \text{g}; (c) I=(0.36±0.01) AI = (0.36 \pm 0.01)\ \text{A}.
Answer

(a) 0.116.4×100%=0.61%\frac{0.1}{16.4} \times 100\% = 0.61\%; (b) 1250×100%=0.4%\frac{1}{250} \times 100\% = 0.4\%; (c) 0.010.36×100%=2.8%\frac{0.01}{0.36} \times 100\% = 2.8\%.

  1. A length is 1.25 m1.25\ \text{m} with a 2%2\% uncertainty. What is the absolute uncertainty?
Answer

ΔL=0.02×1.25 m=0.025 m≈0.03 m\Delta L = 0.02 \times 1.25\ \text{m} = 0.025\ \text{m} \approx 0.03\ \text{m}, so L=(1.25±0.03) mL = (1.25 \pm 0.03)\ \text{m}.

  1. A student measures the speed of sound as (355±10) m/s(355 \pm 10)\ \text{m/s}. The accepted value at room temperature is 343 m/s343\ \text{m/s}. Do the two agree? What is the percentage difference?
Answer

The result covers 345345 to 365 m/s365\ \text{m/s}, so 343 m/s343\ \text{m/s} is just outside: they do not quite agree, a hint of a systematic error (or an underestimated uncertainty). Percentage difference =355−343343×100%=3.5%= \frac{355 - 343}{343} \times 100\% = 3.5\%.

  1. Why is a single swing a poor way to measure a pendulum's period, in terms of percentage uncertainty?
Answer

With a reaction-time uncertainty of about 0.2 s0.2\ \text{s} on a period of about 1.8 s1.8\ \text{s}, the percentage uncertainty is about 11%11\%. Twenty swings (36 s36\ \text{s}) give about 0.6%0.6\%.

Test yourself

What is the percentage uncertainty of (40±2) cm(40 \pm 2)\ \text{cm}?

  1. 2%2\%
  2. 5%5\%
  3. 20%20\%
  4. 0.05%0.05\%

What is the unit of a relative (fractional) uncertainty?

  1. The same as the quantity
  2. The square of the unit
  3. It has no unit
  4. Always metres

Which result is the most precise?

  1. (8.40±0.01) m(8.40 \pm 0.01)\ \text{m}
  2. (2.0±0.5) mm(2.0 \pm 0.5)\ \text{mm}
  3. (64±1) mm(64 \pm 1)\ \text{mm}
  4. (16.4±0.1) s(16.4 \pm 0.1)\ \text{s}

A result is g=(9.6±0.3) m/s2g = (9.6 \pm 0.3)\ \text{m/s}^2. Does it agree with 9.8 m/s29.8\ \text{m/s}^2?

  1. No, it is 0.20.2 too small
  2. Yes, 9.89.8 lies between 9.39.3 and 9.99.9
  3. Only if rounded to 1 s.f.
  4. It cannot be decided