TExcelTAD
Home › Lab Skills: Measurement, Uncertainty & Graphs › Repeated Readings: Mean and Uncertainty

Repeated Readings: Mean and Uncertainty

A question to start

You measure the length of a rod eight times with a millimetre ruler and get 54,53,53,54,52,53,52,52 mm54, 53, 53, 54, 52, 53, 52, 52\ \text{mm}. The rod didn't change. So what is its length, and how sure can you be? This lesson turns a list of scattered readings into one result of the form xˉ±Δx\bar{x} \pm \Delta x.

The idea

Random errors push readings up and down, so the mean of several readings is a better estimate of the true value than any single one. The spread of the readings tells you how big the random error is.

Quantity Symbol How to get it Unit
mean (giá trị trung bình) xˉ\bar{x} add the readings, divide by how many there are same as xx
range xmax−xminx_{max} - x_{min} largest reading minus smallest same as xx
absolute uncertainty (sai số tuyệt đối) Δx\Delta x from the spread (below), never less than the reading uncertainty same as xx
xˉ=x1+x2+⋯+xnn\bar{x} = \frac{x_1 + x_2 + \cdots + x_n}{n}

Two ways to get Δx\Delta x

Schools use two conventions. The simulation offers both.

Rule A: half the range (this course's default).

Δx=xmax−xmin2,but never less than the reading uncertainty\Delta x = \frac{x_{max} - x_{min}}{2}, \quad \text{but never less than the reading uncertainty}

It is quick, and it says: "the readings went from xˉ−Δx\bar{x} - \Delta x to about xˉ+Δx\bar{x} + \Delta x".

Rule B: mean deviation plus instrument uncertainty (used in Vietnamese textbooks). First the mean of the distances of the readings from the mean, then add the instrument's reading uncertainty Δxdc\Delta x_{dc} (sai số dụng cụ):

Δx‾=∣x1−xˉ∣+∣x2−xˉ∣+⋯+∣xn−xˉ∣n,Δx=Δx‾+Δxdc\overline{\Delta x} = \frac{\lvert x_1 - \bar{x} \rvert + \lvert x_2 - \bar{x} \rvert + \cdots + \lvert x_n - \bar{x} \rvert}{n}, \qquad \Delta x = \overline{\Delta x} + \Delta x_{dc}

In this course Δxdc\Delta x_{dc} is half the smallest division (see Reading Scales). Both rules usually give similar answers. Unless a problem says otherwise, use Rule A.

Writing the result: round Δx\Delta x to 1 significant figure, then round xˉ\bar{x} to the same decimal place. Write x=(xˉ±Δx) unitx = (\bar{x} \pm \Delta x)\ \text{unit}.

Worked examples

Example 1: the rod. Given: eight ruler readings 54,53,53,54,52,53,52,52 mm54, 53, 53, 54, 52, 53, 52, 52\ \text{mm}; reading uncertainty 0.5 mm0.5\ \text{mm}. Find: the length with its uncertainty, by both rules. Solve:

xˉ=54+53+53+54+52+53+52+528=4238=52.875 mm\bar{x} = \frac{54 + 53 + 53 + 54 + 52 + 53 + 52 + 52}{8} = \frac{423}{8} = 52.875\ \text{mm}

Rule A: range =54−52=2 mm= 54 - 52 = 2\ \text{mm}, Δx=1 mm\Delta x = 1\ \text{mm} (more than 0.5 mm0.5\ \text{mm}, so it stands). Rule B: the deviations are 1.1251.125 (twice), 0.1250.125 (three times) and 0.8750.875 (three times):

Δx‾=2(1.125)+3(0.125)+3(0.875)8=5.258=0.656 mm,Δx=0.656+0.5=1.16 mm≈1 mm\overline{\Delta x} = \frac{2(1.125) + 3(0.125) + 3(0.875)}{8} = \frac{5.25}{8} = 0.656\ \text{mm}, \qquad \Delta x = 0.656 + 0.5 = 1.16\ \text{mm} \approx 1\ \text{mm}

Answer: both rules give L=(53±1) mmL = (53 \pm 1)\ \text{mm}. Check: Δx\Delta x has one significant figure and the mean is rounded to the same place (whole millimetres). Every reading lies within 5252 to 54 mm54\ \text{mm}.

Press Play and watch the same eight readings arrive. The readouts show the mean, the range and the result; switch the Uncertainty buttons to compare Rule A and Rule B.

8 of 8 readings of the length (mm)50515253545556range 2 mmx̄ = 52.88result: 53 ± 1 mmΔx = (max − min)/2, at least ½ division56cmreading 52 mm ± 0.5 mm (half of 1 mm)

Example 2: when the rules differ. Given: data set 2: 53,52,53,54,51,52,53,54 mm53, 52, 53, 54, 51, 52, 53, 54\ \text{mm}. Find: the result by both rules. Solve: xˉ=4228=52.75 mm\bar{x} = \frac{422}{8} = 52.75\ \text{mm}. Rule A: range =54−51=3 mm= 54 - 51 = 3\ \text{mm}, Δx=1.5 mm≈2 mm\Delta x = 1.5\ \text{mm} \approx 2\ \text{mm} (1 s.f.). Rule B: deviations sum to 6.5 mm6.5\ \text{mm}, so Δx‾=0.8125 mm\overline{\Delta x} = 0.8125\ \text{mm} and Δx=0.8125+0.5=1.3 mm≈1 mm\Delta x = 0.8125 + 0.5 = 1.3\ \text{mm} \approx 1\ \text{mm}. Answer: Rule A: (53±2) mm(53 \pm 2)\ \text{mm}; Rule B: (53±1) mm(53 \pm 1)\ \text{mm}. Check: one reading (51 mm51\ \text{mm}) far from the rest widens the range a lot but the mean deviation only a little. Half the range is the more cautious rule. In the simulation choose data set 2 and switch between the rules.

Example 3: timing. Given: five timings of 10 swings: 16.42,16.31,16.55,16.38,16.49 s16.42, 16.31, 16.55, 16.38, 16.49\ \text{s}. Find: the period TT with its uncertainty (Rule A). Solve: tˉ=82.155=16.43 s\bar{t} = \frac{82.15}{5} = 16.43\ \text{s}; range =16.55−16.31=0.24 s= 16.55 - 16.31 = 0.24\ \text{s}, Δt=0.12 s≈0.1 s\Delta t = 0.12\ \text{s} \approx 0.1\ \text{s}. So t=(16.4±0.1) st = (16.4 \pm 0.1)\ \text{s} for 10 swings, and T=t10T = \frac{t}{10}, ΔT=Δt10\Delta T = \frac{\Delta t}{10}. Answer: T=(1.64±0.01) sT = (1.64 \pm 0.01)\ \text{s}. Check: the half-range 0.12 s0.12\ \text{s} is much bigger than the display's 0.01 s0.01\ \text{s}: reaction time, not the display, sets the uncertainty.

How many readings?

At least three, so that an anomaly stands out. Take more when the readings scatter a lot. More readings make the mean more trustworthy, but they don't make the spread of single readings smaller; with Rule A the range may even grow a little as rare extreme readings turn up. (Upper-secondary and university courses use the standard error, which does shrink with more readings.)

Try it in the simulation: set the spread to 00. Every reading is then the same, the range is 00, and Δx\Delta x is the reading uncertainty, ±0.5 mm\pm 0.5\ \text{mm}, never zero.

Try it: your own repeated readings

Ask four people to measure the width of the same door with the same tape measure, without showing each other their results. Collect the readings, work out the mean, the range and the result by Rule A. Then work it out by Rule B. Which reading is furthest from the mean, and why might that be?

Common mistakes

  • Giving Δx\Delta x with many figures (±1.16 mm\pm 1.16\ \text{mm}). Round it to 1 significant figure.
  • Rounding the mean to a different place than the uncertainty: (52.875±1) mm(52.875 \pm 1)\ \text{mm} is wrong; write (53±1) mm(53 \pm 1)\ \text{mm}.
  • Giving an uncertainty smaller than the reading uncertainty, or zero, when all readings agree.
  • Averaging in an anomaly that you know is a mistake.
  • Using the whole range instead of half of it in Rule A.

Practice

  1. Readings of a thickness: 2.3,2.5,2.4,2.4,2.6 mm2.3, 2.5, 2.4, 2.4, 2.6\ \text{mm} (vernier caliper, reading uncertainty 0.05 mm0.05\ \text{mm}). Give the result by Rule A.
Answer

xˉ=12.25=2.44 mm\bar{x} = \frac{12.2}{5} = 2.44\ \text{mm}; range =2.6−2.3=0.3 mm= 2.6 - 2.3 = 0.3\ \text{mm}, Δx=0.15 mm≈0.2 mm\Delta x = 0.15\ \text{mm} \approx 0.2\ \text{mm}. Result (2.4±0.2) mm(2.4 \pm 0.2)\ \text{mm}.

  1. The same readings by Rule B.
Answer

Deviations from 2.442.44: 0.14,0.06,0.04,0.04,0.160.14, 0.06, 0.04, 0.04, 0.16; sum 0.440.44, mean 0.088 mm0.088\ \text{mm}. Δx=0.088+0.05=0.138 mm≈0.1 mm\Delta x = 0.088 + 0.05 = 0.138\ \text{mm} \approx 0.1\ \text{mm}. Result (2.4±0.1) mm(2.4 \pm 0.1)\ \text{mm}.

  1. Three readings of a voltage are all 1.48 V1.48\ \text{V} on a digital meter. What is the result?
Answer

The range is 00, so ΔU\Delta U is the reading uncertainty, ±1\pm 1 in the last digit: U=(1.48±0.01) VU = (1.48 \pm 0.01)\ \text{V}.

  1. Six timings of a trolley run: 2.41,2.38,2.44,3.40,2.39,2.42 s2.41, 2.38, 2.44, 3.40, 2.39, 2.42\ \text{s}. What do you do with them?
Answer

3.40 s3.40\ \text{s} is an anomaly (probably a late stop). Check, repeat if possible, and leave it out, saying so. From the other five: tˉ=12.045=2.408 s\bar{t} = \frac{12.04}{5} = 2.408\ \text{s}, range 0.06 s0.06\ \text{s}, Δt=0.03 s\Delta t = 0.03\ \text{s}: t=(2.41±0.03) st = (2.41 \pm 0.03)\ \text{s}.

Test yourself

Readings: 12.1,12.4,12.2,12.3 cm12.1, 12.4, 12.2, 12.3\ \text{cm}. By half the range, Δx\Delta x is ...

  1. 0.3 cm0.3\ \text{cm}
  2. 0.15 cm0.15\ \text{cm}, about 0.2 cm0.2\ \text{cm}
  3. 0.1 cm0.1\ \text{cm}
  4. 12.25 cm12.25\ \text{cm}

Which result is written correctly?

  1. (52.875±1) mm(52.875 \pm 1)\ \text{mm}
  2. (53±1.16) mm(53 \pm 1.16)\ \text{mm}
  3. (53±1) mm(53 \pm 1)\ \text{mm}
  4. 53 mm±153\ \text{mm} \pm 1

In Rule B (Vietnamese textbooks), Δx\Delta x is ...

  1. half the range
  2. the mean of ∣xi−xˉ∣\lvert x_i - \bar{x} \rvert plus the instrument's reading uncertainty
  3. the largest reading minus the mean
  4. the reading uncertainty only

All five readings of a length on a millimetre ruler are 87 mm87\ \text{mm}. The result is ...

  1. (87±0) mm(87 \pm 0)\ \text{mm}
  2. (87.0±0.5) mm(87.0 \pm 0.5)\ \text{mm}
  3. (87±1) mm(87 \pm 1)\ \text{mm}
  4. exactly 87 mm87\ \text{mm}