Stopwatches, Thermometers, Meters and Digital Readings
A question to start
Your phone's stopwatch shows for one swing of a pendulum, to a hundredth of a second. Does that mean you timed it to a hundredth of a second? No: your thumb pressed start and stop, and your thumb is far slower than that. Every instrument has a display precision, but what limits a measurement is often something else.
Stopwatches and reaction time
A hand-operated stopwatch is limited by your reaction time (thời gian phản ứng), typically to . Some of that cancels, because you react late both at the start and at the stop, but not all, and not the same every time. A fair estimate for hand timing is an uncertainty of about to per timing, whatever the display shows; the spread of repeated timings tells you more precisely.
How to beat reaction time:
- Time many cycles and divide: the reaction-time doubt is shared out.
- Start and stop as the pendulum passes a fixed marker at its lowest point, where it moves fastest and its position is clearest.
- Count "zero" at the start, not "one".
- Better still, use a light gate with an electronic timer, or film with a phone and step through the frames.
Thermometers
A liquid-in-glass thermometer with divisions has a reading uncertainty of (half a division). Read it with your eye level with the end of the liquid, after the liquid has stopped moving, while the bulb is still in the liquid. Stir the liquid so its temperature is the same everywhere, and keep the bulb off the bottom of a heated beaker.
Ammeters and voltmeters
On an analogue meter, first check what one small division is worth: the ammeter above has 10 small divisions between and , so one division is ; the voltmeter has 5 divisions per volt, each. Then:
- check that the pointer is on zero before switching on (adjust the zero screw if not);
- pick a range where the pointer moves well across the scale;
- read straight on, using the mirror strip if there is one (parallax).
Digital readings
A digital display can't be read "between the marks", so this course takes its reading uncertainty as in the last digit shown. A multimeter showing 1.48 V gives . (Manufacturers often quote a little more, such as " + 2 digits", in the manual.) If the last digit keeps changing, write down the range it jumps over and use its middle, with half the range as the uncertainty.
Summary of reading uncertainties used in this course
| Instrument | Smallest step | Reading uncertainty |
|---|---|---|
| analogue scale (ruler, cylinder, thermometer, meter) | one division | half a division |
| vernier caliper () | ||
| micrometer | ||
| digital display (balance, multimeter, thermometer) | last digit | in the last digit |
| hand-operated stopwatch | display | about to (reaction time) |
Worked examples
Example 1: the meters in the figure. Given: the ammeter needle is 3 small divisions past ; the voltmeter needle 2 small divisions past . Find: both readings with uncertainties. Solve: ammeter: one division , , . Voltmeter: one division , , . Answer: , . Check: both uncertainties are half a division and end at the last decimal place of the value. (You will use these two readings to find a resistance in Combining Uncertainties.)
Example 2: timing many swings. Given: 20 swings take on a hand stopwatch; take the timing uncertainty as . Find: the period and its uncertainty. Formula: , (the 20 is exact). Solve: , . Answer: . Check: timing a single swing would have given on about , more than ; twenty swings bring it down to about .
Try it: measure your reaction time
You need: a ruler and a friend.
- Your friend holds the ruler hanging down, with its zero mark between your open thumb and finger (not touching).
- Without warning, your friend lets go. Catch it as fast as you can and read the distance it fell, at the top of your finger.
- Repeat five times and take the mean. The ruler falls freely, so gives
What you should see: catches between about and , so reaction times of about to . That is why a single hand-timed swing is not good enough.
Common mistakes
- Trusting the display: a stopwatch showing hundredths is still limited by your reaction time.
- Timing one swing when you could time 20.
- Misreading what a small division is worth on a meter: count the divisions between two numbers first.
- Using a range that is far too big, so the pointer barely moves (large relative uncertainty).
- Taking the thermometer out of the liquid to read it.
Practice
- A voltmeter has 10 small divisions between and . Its needle is 7 divisions past . Give the reading with its uncertainty.
Answer
One division , so , : .
- A digital balance reads
152.3 g. Write the result with its uncertainty.
Answer
in the last digit: .
- Ten swings take , timed by hand with an uncertainty of . Find and . How many swings would you need for ?
Answer
, . For : swings.
- A friend catches the dropped ruler after . What is her reaction time?
Answer
.
Test yourself
Why do we time 20 swings of a pendulum rather than 1?
- The pendulum swings faster after a while
- The reaction-time uncertainty is divided by 20
- The display has more digits
- To make the pendulum tired
In this course, what is the reading uncertainty of a digital meter showing 0.473 A?
An ammeter has 10 small divisions between and . What is one division worth?
What is the best place to start and stop the stopwatch for a swinging pendulum?
- At the highest point of the swing
- As it passes a marker at the lowest point
- Whenever you are ready
- When it stops