TExcelTAD
Home › Lab Skills: Measurement, Uncertainty & Graphs › Stopwatches, Thermometers, Meters and Digital Readings

Stopwatches, Thermometers, Meters and Digital Readings

A question to start

Your phone's stopwatch shows 1.79 s1.79\ \text{s} for one swing of a pendulum, to a hundredth of a second. Does that mean you timed it to a hundredth of a second? No: your thumb pressed start and stop, and your thumb is far slower than that. Every instrument has a display precision, but what limits a measurement is often something else.

Stopwatches and reaction time

A hand-operated stopwatch is limited by your reaction time (thời gian phản ứng), typically 0.10.1 to 0.3 s0.3\ \text{s}. Some of that cancels, because you react late both at the start and at the stop, but not all, and not the same every time. A fair estimate for hand timing is an uncertainty of about ±0.1\pm 0.1 to ±0.2 s\pm 0.2\ \text{s} per timing, whatever the display shows; the spread of repeated timings tells you more precisely.

How to beat reaction time:

  • Time many cycles and divide: the reaction-time doubt is shared out.
  • Start and stop as the pendulum passes a fixed marker at its lowest point, where it moves fastest and its position is clearest.
  • Count "zero" at the start, not "one".
  • Better still, use a light gate with an electronic timer, or film with a phone and step through the frames.

Thermometers

A liquid-in-glass thermometer with 1 ∘C1\,^\circ\text{C} divisions has a reading uncertainty of ±0.5 ∘C\pm 0.5\,^\circ\text{C} (half a division). Read it with your eye level with the end of the liquid, after the liquid has stopped moving, while the bulb is still in the liquid. Stir the liquid so its temperature is the same everywhere, and keep the bulb off the bottom of a heated beaker.

Ammeters and voltmeters

0.0 0.2 0.4 0.6 A A 0 1 2 3 4 5 6 V V ammeter 0 to 0.6 Avoltmeter 0 to 6 V

On an analogue meter, first check what one small division is worth: the ammeter above has 10 small divisions between 0.00.0 and 0.2 A0.2\ \text{A}, so one division is 0.02 A0.02\ \text{A}; the voltmeter has 5 divisions per volt, 0.2 V0.2\ \text{V} each. Then:

  • check that the pointer is on zero before switching on (adjust the zero screw if not);
  • pick a range where the pointer moves well across the scale;
  • read straight on, using the mirror strip if there is one (parallax).

Digital readings

A digital display can't be read "between the marks", so this course takes its reading uncertainty as ±1\pm 1 in the last digit shown. A multimeter showing 1.48 V gives (1.48±0.01) V(1.48 \pm 0.01)\ \text{V}. (Manufacturers often quote a little more, such as "±0.5%\pm 0.5\% + 2 digits", in the manual.) If the last digit keeps changing, write down the range it jumps over and use its middle, with half the range as the uncertainty.

Summary of reading uncertainties used in this course

Instrument Smallest step Reading uncertainty
analogue scale (ruler, cylinder, thermometer, meter) one division half a division
vernier caliper (0.1 mm0.1\ \text{mm}) 0.1 mm0.1\ \text{mm} ±0.05 mm\pm 0.05\ \text{mm}
micrometer 0.01 mm0.01\ \text{mm} ±0.005 mm\pm 0.005\ \text{mm}
digital display (balance, multimeter, thermometer) last digit ±1\pm 1 in the last digit
hand-operated stopwatch display 0.01 s0.01\ \text{s} about ±0.1\pm 0.1 to 0.2 s0.2\ \text{s} (reaction time)

Worked examples

Example 1: the meters in the figure. Given: the ammeter needle is 3 small divisions past 0.3 A0.3\ \text{A}; the voltmeter needle 2 small divisions past 4 V4\ \text{V}. Find: both readings with uncertainties. Solve: ammeter: one division =0.02 A= 0.02\ \text{A}, I=0.30+3×0.02=0.36 AI = 0.30 + 3 \times 0.02 = 0.36\ \text{A}, ΔI=0.01 A\Delta I = 0.01\ \text{A}. Voltmeter: one division =0.2 V= 0.2\ \text{V}, U=4.0+2×0.2=4.4 VU = 4.0 + 2 \times 0.2 = 4.4\ \text{V}, ΔU=0.1 V\Delta U = 0.1\ \text{V}. Answer: I=(0.36±0.01) AI = (0.36 \pm 0.01)\ \text{A}, U=(4.4±0.1) VU = (4.4 \pm 0.1)\ \text{V}. Check: both uncertainties are half a division and end at the last decimal place of the value. (You will use these two readings to find a resistance in Combining Uncertainties.)

Example 2: timing many swings. Given: 20 swings take 35.92 s35.92\ \text{s} on a hand stopwatch; take the timing uncertainty as ±0.2 s\pm 0.2\ \text{s}. Find: the period TT and its uncertainty. Formula: T=t20T = \frac{t}{20}, ΔT=Δt20\Delta T = \frac{\Delta t}{20} (the 20 is exact). Solve: T=35.92 s20=1.796 sT = \frac{35.92\ \text{s}}{20} = 1.796\ \text{s}, ΔT=0.2 s20=0.01 s\Delta T = \frac{0.2\ \text{s}}{20} = 0.01\ \text{s}. Answer: T=(1.80±0.01) sT = (1.80 \pm 0.01)\ \text{s}. Check: timing a single swing would have given ±0.2 s\pm 0.2\ \text{s} on about 1.8 s1.8\ \text{s}, more than 10%10\%; twenty swings bring it down to about 0.6%0.6\%.

Try it: measure your reaction time

You need: a 30 cm30\ \text{cm} ruler and a friend.

  1. Your friend holds the ruler hanging down, with its zero mark between your open thumb and finger (not touching).
  2. Without warning, your friend lets go. Catch it as fast as you can and read the distance dd it fell, at the top of your finger.
  3. Repeat five times and take the mean. The ruler falls freely, so d=12gt2d = \frac{1}{2} g t^2 gives
t=2dg,for d=20 cm:t=2×0.20 m9.8 m/s2=0.20 st = \sqrt{\frac{2d}{g}}, \qquad \text{for } d = 20\ \text{cm}: \quad t = \sqrt{\frac{2 \times 0.20\ \text{m}}{9.8\ \text{m/s}^2}} = 0.20\ \text{s}

What you should see: catches between about 1010 and 30 cm30\ \text{cm}, so reaction times of about 0.140.14 to 0.25 s0.25\ \text{s}. That is why a single hand-timed swing is not good enough.

Common mistakes

  • Trusting the display: a stopwatch showing hundredths is still limited by your reaction time.
  • Timing one swing when you could time 20.
  • Misreading what a small division is worth on a meter: count the divisions between two numbers first.
  • Using a range that is far too big, so the pointer barely moves (large relative uncertainty).
  • Taking the thermometer out of the liquid to read it.

Practice

  1. A voltmeter has 10 small divisions between 00 and 1 V1\ \text{V}. Its needle is 7 divisions past 2 V2\ \text{V}. Give the reading with its uncertainty.
Answer

One division =0.1 V= 0.1\ \text{V}, so U=2.7 VU = 2.7\ \text{V}, ΔU=0.05 V\Delta U = 0.05\ \text{V}: U=(2.70±0.05) VU = (2.70 \pm 0.05)\ \text{V}.

  1. A digital balance reads 152.3 g. Write the result with its uncertainty.
Answer

±1\pm 1 in the last digit: (152.3±0.1) g(152.3 \pm 0.1)\ \text{g}.

  1. Ten swings take 16.4 s16.4\ \text{s}, timed by hand with an uncertainty of ±0.2 s\pm 0.2\ \text{s}. Find TT and ΔT\Delta T. How many swings would you need for ΔT=0.005 s\Delta T = 0.005\ \text{s}?
Answer

T=1.64 sT = 1.64\ \text{s}, ΔT=0.210=0.02 s\Delta T = \frac{0.2}{10} = 0.02\ \text{s}. For ΔT=0.005 s\Delta T = 0.005\ \text{s}: N=0.20.005=40N = \frac{0.2}{0.005} = 40 swings.

  1. A friend catches the dropped ruler after d=15 cmd = 15\ \text{cm}. What is her reaction time?
Answer

t=2×0.15 m9.8 m/s2=0.0306 s2=0.17 st = \sqrt{\frac{2 \times 0.15\ \text{m}}{9.8\ \text{m/s}^2}} = \sqrt{0.0306\ \text{s}^2} = 0.17\ \text{s}.

Test yourself

Why do we time 20 swings of a pendulum rather than 1?

  1. The pendulum swings faster after a while
  2. The reaction-time uncertainty is divided by 20
  3. The display has more digits
  4. To make the pendulum tired

In this course, what is the reading uncertainty of a digital meter showing 0.473 A?

  1. ±0.0005 A\pm 0.0005\ \text{A}
  2. ±0.001 A\pm 0.001\ \text{A}
  3. ±0.01 A\pm 0.01\ \text{A}
  4. ±0.1 A\pm 0.1\ \text{A}

An ammeter has 10 small divisions between 00 and 0.2 A0.2\ \text{A}. What is one division worth?

  1. 0.01 A0.01\ \text{A}
  2. 0.02 A0.02\ \text{A}
  3. 0.1 A0.1\ \text{A}
  4. 0.2 A0.2\ \text{A}

What is the best place to start and stop the stopwatch for a swinging pendulum?

  1. At the highest point of the swing
  2. As it passes a marker at the lowest point
  3. Whenever you are ready
  4. When it stops