AC Thevenin, Norton and Superposition
A small antenna-matching or sensor-readout problem: a source network with a capacitor at its output delivers power to a load, and you may choose the load. Which load takes the most power, and how much? A second question from the same bench: a resistor-inductor load is driven by a DC bias plus a 1 kHz signal. How hot does the resistor get? Both answers use the network theorems you know from DC (Thevenin and Norton Equivalents, Linearity and Superposition, Maximum Power Transfer), now with impedances, plus one rule that is new in AC: superposition across different frequencies must be done in the time domain.
Thevenin and Norton with impedances
Any linear network of impedances and same-frequency sources, seen from two terminals, behaves like
- a Thevenin source in series with , or
- a Norton source in parallel with ,
with
can also be found by turning off the independent sources (voltage sources shorted, current sources opened) and combining impedances, or with a test source when dependent sources are present (Thevenin Equivalents with Dependent Sources and from Measurements). The one restriction: the equivalent is valid at one frequency only, because and both depend on . Its terminal behaviour is right for any load at that frequency, the internal power dissipation is not.
Maximum power transfer in AC
With a load on the Thevenin equivalent, the load current is and the average load power is
(RMS phasors). Two choices maximise it. First, make the reactances cancel, , which removes the second term of the denominator. Then the remaining problem is the DC one, solved by . Together:
If the load must be a pure resistance, the best value is , which gives less than the conjugate match. As in DC, a conjugate match wastes half the power in the source: it is the right goal in signal and RF circuits (antennas, receivers, sensors), never in power distribution.
Worked example: Thevenin and the best load
Given: RMS at , in series, across the output terminals (figure).
Find: , , , the conjugate-matched load and its power; compare with the best resistive load.
Solve: .
The best resistor is , which takes (92 % of the maximum).
Check: turning off the source (short) leaves in parallel with : , the same . Note that the maximum, , equals : the conjugate load "tunes out" the capacitor, which then neither adds nor removes available power.
import numpy as np
def pol(z, unit):
return f"{abs(z):.4g} {unit} at {np.degrees(np.angle(z)):+.2f} deg"
w = 2 * np.pi * 1e3
V, R1 = 10.0, 100.0
ZC = 1 / (1j * w * 1e-6)
Voc = V * ZC / (R1 + ZC) # open circuit: divider
Isc = V / R1 # short circuit: C is bypassed
Zth = Voc / Isc
print("V_th =", pol(Voc, "V"), "| I_N =", pol(Isc, "A"))
print(f"Z_th = {Zth.real:.3f} {Zth.imag:+.3f}j ohm")
def p_load(ZL):
I = Voc / (Zth + ZL)
return abs(I) ** 2 * ZL.real
print("load P (W)")
for name, ZL in [("R = R_th", Zth.real), ("R = |Z_th|", abs(Zth)),
("R = 2 |Z_th|", 2 * abs(Zth)), ("Z = conj(Z_th)", np.conj(Zth))]:
print(f"{name:20s} {p_load(complex(ZL)):10.4f}")
print(f"conjugate match: R = {Zth.real:.2f} ohm + L = {-Zth.imag / w * 1e3:.3f} mH")V_th = 8.467 V at -32.14 deg | I_N = 0.1 A at +0.00 deg
Z_th = 71.696 -45.048j ohm
load P (W)
R = R_th 0.2275
R = |Z_th| 0.2293
R = 2 |Z_th| 0.2019
Z = conj(Z_th) 0.2500
conjugate match: R = 71.70 ohm + L = 7.170 mH
The lab connects the conjugate load (a resistor in series with an inductor) to the original network. At the defaults it reads at , so . Move or away from the match, or away from 1 kHz, and falls.
Superposition across frequencies
Superposition holds in any linear circuit: the response to several sources is the sum of the responses to each alone. When the sources share one frequency, you may add their phasors. When the frequencies differ (including DC, which is ), you must:
- solve the circuit once per frequency, with the other sources turned off and the impedances evaluated at that frequency ( and at DC);
- convert each answer to a time function;
- add the time functions.
Average power in a resistor then adds frequency by frequency, because cross terms between different frequencies average to zero over a common period:
Example. in series with , driven by DC plus RMS at 1 kHz. DC: . AC: . So
and the resistor dissipates .
import numpy as np
R, L, f = 100.0, 10e-3, 1e3
w = 2 * np.pi * f
I_dc = 5.0 / R # DC: inductor is a short
I_ac = 2.0 / (R + 1j * w * L) # 2 V rms at 1 kHz
print(f"DC part: {I_dc * 1e3:.2f} mA")
print(f"AC part: {abs(I_ac) * 1e3:.3f} mA rms at {np.degrees(np.angle(I_ac)):.2f} deg")
I_rms = np.sqrt(I_dc ** 2 + abs(I_ac) ** 2)
print(f"total rms {I_rms * 1e3:.3f} mA, P(R) = {I_rms ** 2 * R:.4f} W")
# the same from samples of i(t) over one period
t = np.linspace(0, 1 / f, 20000, endpoint=False)
i = I_dc + np.sqrt(2) * abs(I_ac) * np.cos(w * t + np.angle(I_ac))
print(f"sampled: rms {np.sqrt(np.mean(i ** 2)) * 1e3:.3f} mA, peak {i.max() * 1e3:.2f} mA")DC part: 50.00 mA
AC part: 16.935 mA rms at -32.14 deg
total rms 52.790 mA, P(R) = 0.2787 W
sampled: rms 52.790 mA, peak 73.95 mA
Guided lab: measure a Thevenin equivalent at 1 kHz
Hand calculation. The network above, driven by a function generator at peak (generator set to high-impedance load mode, output measured at the board): peak at . With a resistor as load: , which is peak at .
Simulation. The netlist lab with V1 in 0 AC 5, RL t 0 100 and no inductor reproduces those numbers; with no load at all ( very large) it shows .
What you would measure. (1) Open-circuit voltage at t: amplitude and phase against the generator. (2) Voltage across a known load. Then , complex, from the two amplitudes and their phases. Expect , , and a computed within about 5 % of (limited by the capacitor tolerance and by reading phases to about ). The generator's own output resistance adds to unless you measure at the board and treat the measured node as the source.
Hazards and safe setup. Signal level only ( peak), common ground for generator and scope. A short-circuit test is harmless here, but on any real supply measure only when you know it is current-limited; otherwise use the two-load method above.
Pitfalls
- Using the Thevenin equivalent at another frequency. Recompute it for each .
- Matching instead of . Equal reactances add instead of cancelling.
- Adding phasors of different frequencies. Add time functions; add powers (or squared RMS values), never RMS values themselves.
- Forgetting DC values of reactive elements. Inductors are shorts and capacitors opens at DC.
- Applying maximum power transfer to supplies. A grid or battery is designed for efficiency, with .
Practice
- For the worked example at , find .
- A network has and RMS. What load takes the most power, and how much?
- A resistor carries DC plus RMS at 50 Hz plus RMS at 150 Hz. What is the total RMS current?
Answer
- ; .
- (a capacitive load); .
- .
Test yourself
A source has . Which load impedance takes the most average power?
If the load must be a pure resistor, which value takes the most power from ?
A current is DC plus RMS at 50 Hz. What is its RMS value?
- 7 A
- 5 A
- 1 A
- 3.5 A
Why is an AC Thevenin equivalent valid at one frequency only?
- because sources are sinusoidal
- because and contain reactances that depend on
- because Thevenin's theorem needs DC
- it is valid at all frequencies