Maximum Power Transfer
A microphone, an antenna or a thermocouple delivers very little power, and you want as much of it as possible in the amplifier. A car battery or the mains delivers a lot, and you want as little as possible wasted inside the source. These two goals lead to opposite designs. The maximum power transfer theorem tells you which load resistance draws the most power from a source with a given internal resistance, and its other half, the efficiency, tells you why power engineers never use that load.
The idea
Any linear source, seen from its terminals, is a Thevenin equivalent behind . Connect a load . With the current is largest but the load voltage is zero; with the voltage is largest but the current is zero. Power, the product, is zero at both ends, so it has a maximum somewhere in between.
The theorem
The load current and power are
Differentiate with respect to and set the result to zero:
so the load power is largest when the load matches the source:
At that point the load voltage is , and exactly as much power is burnt in as is delivered. The efficiency of the transfer,
is therefore at the maximum, rises toward for , and the peak of is flat: or still delivers of .
Two practical rules follow:
- Signals (antennas, RF amplifiers, transmission lines, sensor and audio links where power is scarce): match. In AC circuits the condition becomes the complex conjugate, (AC Thevenin, Norton and Superposition).
- Power (batteries, supplies, the grid): make . A supply with output resistance feeding a load runs at 99 % efficiency, far from the "maximum power" point, which would be a near short circuit dissipating as much inside the source as outside.
The theorem fixes the source and asks for the best load. If you can choose the source resistance instead, the answer is , not : never "match" by adding resistance to a source.
Worked example
Given: the network of the Thevenin lesson: , , , , so , .
Find: the load for maximum power, , the efficiency relative to the equivalent, and the fraction of 's actual output that reaches the load.
Solve:
Check: in the equivalent, dissipates , equal to : 50 %. In the real network the efficiency is only 26.5 %, because wastes power even with no load. The Thevenin equivalent reproduces the terminal behaviour exactly, not the power dissipated inside.
In Python: the power curve and the optimum
import numpy as np
from scipy.optimize import minimize_scalar
import matplotlib.pyplot as plt
Vth, Rth = 9.0, 4.0 # V, kOhm
P = lambda RL: Vth**2 * RL / (Rth + RL)**2 # mW
eta = lambda RL: RL / (Rth + RL)
print(" RL (k) P_L (mW) P/Pmax efficiency")
for RL in [0.5, 1, 2, 4, 8, 16, 40]:
print(f"{RL:6.1f} {P(RL):10.3f} {P(RL) / P(Rth):8.3f} {100 * eta(RL):9.1f} %")
res = minimize_scalar(lambda r: -P(r), bounds=(0.01, 100), method="bounded")
print(f"numerical optimum: RL = {res.x:.4f} kOhm, P = {-res.fun:.4f} mW")
RL = np.logspace(-1, 2, 200)
fig, ax = plt.subplots()
ax.semilogx(RL, P(RL), label="P_L (mW)")
ax.semilogx(RL, 5 * eta(RL), "--", label="efficiency x 5 (0..5 = 0..100 %)")
ax.axvline(Rth, color="gray", linewidth=0.8)
ax.set_xlabel("R_L (kOhm)"); ax.legend(); ax.set_title("V_Th = 9 V, R_Th = 4 kOhm")
plt.show() RL (k) P_L (mW) P/Pmax efficiency
0.5 2.000 0.395 11.1 %
1.0 3.240 0.640 20.0 %
2.0 4.500 0.889 33.3 %
4.0 5.062 1.000 50.0 %
8.0 4.500 0.889 66.7 %
16.0 3.240 0.640 80.0 %
40.0 1.674 0.331 90.9 %
numerical optimum: RL = 4.0000 kOhm, P = 5.0625 mW
The table shows the symmetry on a log scale: and give the same power (), as do and . Efficiency keeps climbing past the peak; gives 64 % of the maximum power at 80 % efficiency, often the better engineering trade.
Interactive: a source with internal resistance
The dc-power lab is a cell with emf (written , the lab calls the terminal voltage ) and internal resistance , driving . Its graph of against peaks at .
With and the lab reads , , (the maximum ), lost in , and . Raise to : falls to while rises to 80 %. (These are simulation numbers; the hands-on version below stays at milliwatts.)
Guided lab: find the peak by measurement
Hand calculation. Make a "source" from a bench supply at and a series resistor, so and (plus a fraction of an ohm from the supply and wiring). Predicted at , where .
Simulation. Change Vth, Rth = 5.0, 0.1 (V and ) in the Python example and list the E12 loads below.
What you would measure. Connect loads of (0.25 W or larger) in turn and measure with a DMM; compute using each resistor's measured value. Expect the largest power at , about , with and only 4 % lower ( and ): the peak is flat, so your measured maximum can easily land on a neighbour if the resistors are 5 % parts. Plot against on a log axis and compare with the curve.
Hazards and safe setup. 5 V with the current limit at (the largest current, into , is ). The source resistor dissipates up to at the load: use a 0.5 W part. Never test maximum power transfer on a battery or a supply output directly: matching a low internal resistance means a near short circuit.
Pitfalls
- Maximising power is not maximising efficiency. At the maximum, half the power is lost in the source.
- Choosing the source. The theorem gives the best load for a fixed source; for a free choice of source, lower is always better.
- Using the equivalent for internal power. 's dissipation is not the real network's internal loss.
- Forgetting ratings. At the matched point the source dissipates as much as the load; check that it can.
- AC loads. With reactance the condition is , not .
Practice
- A sensor has and . What is the maximum power it can deliver?
- A battery with internal resistance feeds a heater. Find the efficiency and the heater power. What would the "matched" load dissipate, and why is that a bad idea?
- For which is ?
Answer
- .
- ; , . Matched (): in the load and another inside the battery: a near short circuit that would overheat the battery.
- With : : or .
Test yourself
A source has and . What is the maximum power it can deliver to a resistive load?
At the maximum-power load, the efficiency of the transfer (relative to the Thevenin equivalent) is…
- 100 %
- 75 %
- 50 %
- 25 %
Why are power supplies and the grid not operated at maximum power transfer?
- it is impossible to match their loads
- half the power would be wasted inside the source, and the current would be enormous
- the theorem only applies to AC
- the theorem only applies to batteries
With , the load receives what fraction of ?