Mutual Inductance and the Dot Convention
Hold a phone over a wireless charging pad and energy crosses a gap of several millimetres with no wire. Put two PCB traces side by side and a fast edge on one appears as a small spike on the other. Both are mutual inductance: the magnetic flux of one coil's current links a second coil, and a changing current in the first induces a voltage in the second. Transformers, current sensors, coupled resonators and crosstalk all rest on it. This lesson adds the coupled-coil equations to circuit analysis and explains the dot convention that fixes their signs. Faraday's law behind it is refreshed in Magnetism, Induction and Inductance.
Self and mutual inductance
A coil's own flux gives its self-inductance, (Inductors in Circuits). When part of the flux of coil 1 also passes through coil 2, a changing induces a voltage in coil 2 as well:
(in henries) is the mutual inductance; it is the same in both directions (reciprocity). How much of the flux is shared is measured by the coupling coefficient
Air-cored coils side by side have of a few percent to perhaps 0.3; coils wound on a shared ferrite or iron core reach 0.95 to 0.999. The limit follows from energy: the stored energy
must be non-negative for every pair of currents, which requires .
The dot convention
Whether the mutual term is added or subtracted depends on how the coils are wound, which a schematic cannot show. Instead one end of each coil carries a dot:
If both currents enter (or both leave) the dotted terminals, the mutual voltage terms have the same sign as the self terms (). If one current enters a dot and the other leaves one, use .
Equivalently: a current entering the dot of one coil induces a voltage that is positive at the dot of the other coil. Dots are found by measurement (below) or from the winding direction.
Phasor form and reflected impedance
In sinusoidal steady state . With the reference directions of the figure (both currents into the dots):
With a load on coil 2, (the load current flows out of the dot). Eliminating gives the impedance seen at the primary:
The second term is the reflected impedance. Note the sign of drops out (it appears squared): the dots matter for the phase of , not for what the source sees. A resistive load reflects as a resistance plus a negative (capacitive-looking) reactance that partly cancels .
Worked example
Given: the circuit above: , , , , source (amplitude) at .
Find: , , , the load voltage and the power delivered to the load.
Solve: .
Check: the power entering the primary, , equals the load power: ideal coupled coils store energy but dissipate none.
In Python: solve the coupled equations as a matrix
import numpy as np
L1, L2, k, RL = 10e-3, 40e-3, 0.5, 100.0
M = k * np.sqrt(L1 * L2)
w = 2 * np.pi * 1e3
# unknowns I1, I2 (both into the dots); KVL: V1 = jwL1 I1 + jwM I2 ; 0 = jwM I1 + (jwL2 + RL) I2
A = np.array([[1j * w * L1, 1j * w * M],
[1j * w * M, 1j * w * L2 + RL]])
I1, I2 = np.linalg.solve(A, np.array([10.0, 0.0]))
V2 = -RL * I2
pol = lambda z, u: f"{abs(z):.4g} {u} at {np.degrees(np.angle(z)):.2f} deg"
print(f"M = {M*1e3:.1f} mH")
print("Z_in =", np.round(10.0 / I1, 2), "ohm")
print("I1 =", pol(I1, "A"))
print("V2 =", pol(V2, "V"))
print(f"P_in = {0.5*(10.0*np.conj(I1)).real:.4f} W, P_load = {0.5*abs(I2)**2*RL:.4f} W")
print(f"series aiding: {(L1+L2+2*M)*1e3:.0f} mH, series opposing: {(L1+L2-2*M)*1e3:.0f} mH")M = 10.0 mH
Z_in = (5.4+49.27j) ohm
I1 = 0.2018 A at -83.75 deg
V2 = 4.686 V at -62.05 deg
P_in = 0.1098 W, P_load = 0.1098 W
series aiding: 70 mH, series opposing: 30 mH
Cross-check with SPICE: a K coupling statement
SPICE describes coupling with a K line naming two inductors and . The first node of each inductor is its dotted end. Phases are printed in radians, and the source current is measured into its + terminal.
cat > coupled.cir <<'EOF'
* Coupled coils: L1 = 10m, L2 = 40m, k = 0.5, 100 ohm load, 10 V at 1 kHz
V1 in 0 AC 10
L1 in 0 10m
L2 out 0 40m
K1 L1 L2 0.5
RL out 0 100
.control
ac lin 1 1k 1k
print vm(out) vp(out) mag(i(V1)) ph(i(V1))
.endc
.end
EOF
ngspice -b coupled.cir 2>&1 | grep -E '^(vm|vp|mag|ph)'vm(out) = 4.686498e+00
vp(out) = -1.08303e+00
mag(i(v1)) = 2.017538e-01
ph(i(v1)) = 1.679874e+00
, and the source current at is turned by (SPICE's sign convention): all as computed by hand.
Guided lab: find M and the dots from two series connections
Connecting the coils in series adds or subtracts the mutual flux. With the dots on the same side (series aiding) and on opposite sides (series opposing):
Hand calculation. For the example coils: and , so and .
Simulation. The last line of the Python output; or in SPICE, connect L1 and L2 in series in both orders and run ac to read the impedance.
What you would measure. Use a small low-voltage signal or audio transformer with two separate windings (or two identical chokes taped side by side). Measure and alone with an LCR meter at 1 kHz, then both series connections. The larger reading is the aiding connection. In it the current runs into the dot of one winding, out of its undotted end and into the dot of the other, so mark the free end of winding 1 and the joined end of winding 2 as the dots. Confirm with a scope: drive winding 1 from a function generator ( peak-to-peak, 1 kHz, through ) and the voltage at the dotted end of winding 2 is in phase with the dotted end of winding 1. A transformer on a shared core should give of 0.95 or more; two air-cored chokes side by side give a few hundredths. LCR meters read inductance to about 1 to 2 %, but comes from a difference: when is small, and are close and the relative uncertainty of grows. For with , a 1 % error on each reading () gives .
Hazards and safe setup. Function generator only, never a mains transformer's primary from the mains. An inductor with a DC current interrupted produces a voltage spike; with a few milliamps from a generator this is harmless, but do not drive coils from a bench supply and then pull a lead.
Pitfalls
- Dropping the mutual terms' signs. Decide the reference directions first, then apply the dot rule term by term.
- Assuming . Real coupled coils leak flux; the leakage acts like a series inductance and limits how much power transfers.
- Forgetting that mutual voltages need changing current. DC through one coil induces nothing in the other once steady.
- SPICE coil orientation. Swapping the two nodes of an inductor in a deck flips its dot.
Practice
- Two coils of and have . Find and both series inductances.
- In the worked example, make the load a short circuit. What is ?
- Series aiding reads and series opposing . Find .
Answer
- ; aiding , opposing .
- . A shorted secondary leaves the primary with only its leakage-like inductance .
- .
Test yourself
Two coils have , and . Their mutual inductance is…
Current enters the dot of coil 1 and leaves the dot of coil 2. The mutual term in (positive at coil 1's dot) is…
- zero
Why must the coupling coefficient satisfy ?
- because flux is measured in webers
- otherwise the stored energy could be negative for some currents
- because of Ohm's law
- it need not; can exceed 1 with ferrite
The reflected impedance depends on the dot positions…
- yes, its sign flips
- no, appears squared
- only for capacitive loads
- only at resonance