TExcelTAD
Home › COBOL › COBOL Exercises

COBOL Exercises

Time to practise. Each exercise has a starter program that compiles and runs as it is, printing a placeholder result so you can see the expected format. Replace the TODO parts, press Run, and compare your output with the "Expected" lines. If you get stuck, open the solution, but try for a few minutes first. Remember the column rules: code starts in column 8, and nothing may go past column 72.

# Exercise Topics
1 Temperature table PERFORM VARYING, COMPUTE, edited pictures
2 FizzBuzz EVALUATE TRUE, FUNCTION MOD
3 Change maker DIVIDE … REMAINDER, tables
4 Grade report level-88 ranges, EVALUATE
5 Vowel counter INSPECT TALLYING, UPPER-CASE
6 Name swap UNSTRING, STRING
7 Temperature statistics tables, signed numbers, ROUNDED
8 Leap years MOD, condition names

1. Temperature table

Print a conversion table from Celsius to Fahrenheit for -10, 0, 10, 20, 30 and 40 °C, using F = C × 9 / 5 + 32. Show Celsius with the edited picture ---9 and Fahrenheit with ---9.9.

Expected: first line -10 C = 14.0 F, last line 40 C = 104.0 F.

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. TEMP-TABLE.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-CELSIUS         PIC S999    VALUE 0.
       01  WS-FAHRENHEIT      PIC S999V9  VALUE 0.
       PROCEDURE DIVISION.
      *> TODO: loop from -10 to 40 in steps of 10,
      *>       compute Fahrenheit and print edited values
           DISPLAY WS-CELSIUS " C = " WS-FAHRENHEIT " F"
           STOP RUN.
+000 C = +000.0 F
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. TEMP-TABLE.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-CELSIUS         PIC S999.
       01  WS-FAHRENHEIT      PIC S999V9.
       01  ED-C               PIC ---9.
       01  ED-F               PIC ---9.9.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-CELSIUS FROM -10 BY 10
                   UNTIL WS-CELSIUS > 40
               COMPUTE WS-FAHRENHEIT = WS-CELSIUS * 9 / 5 + 32
               MOVE WS-CELSIUS TO ED-C
               MOVE WS-FAHRENHEIT TO ED-F
               DISPLAY ED-C " C = " ED-F " F"
           END-PERFORM
           STOP RUN.

2. FizzBuzz

For the numbers 1 to 15, print Fizz for multiples of 3, Buzz for multiples of 5, FizzBuzz for multiples of both, and the number otherwise, all on one line separated by spaces. Print numbers without leading zeros.

Expected: 1 2 Fizz 4 Buzz Fizz 7 8 Fizz Buzz 11 Fizz 13 14 FizzBuzz

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. FIZZBUZZ.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-N               PIC 99.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-N FROM 1 BY 1 UNTIL WS-N > 3
      *> TODO: use EVALUATE TRUE with FUNCTION MOD
               DISPLAY WS-N " " WITH NO ADVANCING
           END-PERFORM
           DISPLAY " "
           STOP RUN.
01 02 03
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. FIZZBUZZ.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-N               PIC 99.
       01  ED-N               PIC Z9.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-N FROM 1 BY 1 UNTIL WS-N > 15
               EVALUATE TRUE
                   WHEN FUNCTION MOD(WS-N, 15) = 0
                       DISPLAY "FizzBuzz " WITH NO ADVANCING
                   WHEN FUNCTION MOD(WS-N, 3) = 0
                       DISPLAY "Fizz " WITH NO ADVANCING
                   WHEN FUNCTION MOD(WS-N, 5) = 0
                       DISPLAY "Buzz " WITH NO ADVANCING
                   WHEN OTHER
                       MOVE WS-N TO ED-N
                       DISPLAY FUNCTION TRIM(ED-N) " "
                           WITH NO ADVANCING
               END-EVALUATE
           END-PERFORM
           DISPLAY " "
           STOP RUN.

3. Change maker

Split 287 cents into the fewest coins of 200, 100, 50, 20, 10, 5, 2 and 1 cents. Use DIVIDE … GIVING … REMAINDER in a loop over a table of coin values, and print one line per coin.

Expected: 01 x 200, 00 x 100, 01 x 050, … and Left over: 000.

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. CHANGE-MAKER.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-CENTS           PIC 999     VALUE 287.
       01  WS-COUNT           PIC 99      VALUE 0.
       PROCEDURE DIVISION.
           DISPLAY "Change for " WS-CENTS " cents:"
      *> TODO: build a table of the 8 coin values and loop over it
           DISPLAY "  " WS-COUNT " x 200"
           DISPLAY "Left over: " WS-CENTS
           STOP RUN.
Change for 287 cents:
  00 x 200
Left over: 287
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. CHANGE-MAKER.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-CENTS           PIC 999     VALUE 287.
       01  WS-COIN-DATA       PIC X(24)
           VALUE "200100050020010005002001".
       01  WS-COINS REDEFINES WS-COIN-DATA.
           05  WS-COIN        PIC 999     OCCURS 8 TIMES.
       01  WS-COUNT           PIC 99.
       01  WS-I               PIC 9.
       PROCEDURE DIVISION.
           DISPLAY "Change for " WS-CENTS " cents:"
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 8
               DIVIDE WS-CENTS BY WS-COIN (WS-I) GIVING WS-COUNT
                   REMAINDER WS-CENTS
               DISPLAY "  " WS-COUNT " x " WS-COIN (WS-I)
           END-PERFORM
           DISPLAY "Left over: " WS-CENTS
           STOP RUN.

4. Grade report

Give each score a grade: 90–100 is A, 75–89 B, 50–74 C, anything lower F. Declare the bands as level-88 condition names on the score item and choose the grade with EVALUATE TRUE.

Expected: 092 -> A, 078 -> B, 055 -> C, 041 -> F, 100 -> A.

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. GRADES.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-SCORE-DATA      PIC X(15)   VALUE "092078055041100".
       01  WS-SCORES REDEFINES WS-SCORE-DATA.
           05  WS-SCORE-ITEM  PIC 999     OCCURS 5 TIMES.
       01  WS-SCORE           PIC 999.
      *> TODO: add 88-levels GRADE-A, GRADE-B, GRADE-C
       01  WS-GRADE           PIC X       VALUE "?".
       01  WS-I               PIC 9.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 5
               MOVE WS-SCORE-ITEM (WS-I) TO WS-SCORE
      *> TODO: set WS-GRADE with EVALUATE TRUE
               DISPLAY WS-SCORE " -> " WS-GRADE
           END-PERFORM
           STOP RUN.
092 -> ?
078 -> ?
055 -> ?
041 -> ?
100 -> ?
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. GRADES.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-SCORE-DATA      PIC X(15)   VALUE "092078055041100".
       01  WS-SCORES REDEFINES WS-SCORE-DATA.
           05  WS-SCORE-ITEM  PIC 999     OCCURS 5 TIMES.
       01  WS-SCORE           PIC 999.
           88  GRADE-A                    VALUE 90 THRU 100.
           88  GRADE-B                    VALUE 75 THRU 89.
           88  GRADE-C                    VALUE 50 THRU 74.
       01  WS-GRADE           PIC X.
       01  WS-I               PIC 9.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 5
               MOVE WS-SCORE-ITEM (WS-I) TO WS-SCORE
               EVALUATE TRUE
                   WHEN GRADE-A MOVE "A" TO WS-GRADE
                   WHEN GRADE-B MOVE "B" TO WS-GRADE
                   WHEN GRADE-C MOVE "C" TO WS-GRADE
                   WHEN OTHER   MOVE "F" TO WS-GRADE
               END-EVALUATE
               DISPLAY WS-SCORE " -> " WS-GRADE
           END-PERFORM
           STOP RUN.

5. Vowel counter

Count the vowels (A, E, I, O, U in either case) in the text Common Business Oriented Language. Convert the text to upper case first, then use a single INSPECT … TALLYING with several ALL phrases.

Expected: Vowels: 13

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. VOWELS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-TEXT            PIC X(40)
           VALUE "Common Business Oriented Language".
       01  WS-VOWELS          PIC 99      VALUE 0.
       PROCEDURE DIVISION.
      *> TODO: upper-case the text and count the vowels
           DISPLAY "Vowels: " WS-VOWELS
           STOP RUN.
Vowels: 00
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. VOWELS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-TEXT            PIC X(40)
           VALUE "Common Business Oriented Language".
       01  WS-UPPER           PIC X(40).
       01  WS-VOWELS          PIC 99      VALUE 0.
       PROCEDURE DIVISION.
           MOVE FUNCTION UPPER-CASE(WS-TEXT) TO WS-UPPER
           INSPECT WS-UPPER TALLYING WS-VOWELS
               FOR ALL "A" ALL "E" ALL "I" ALL "O" ALL "U"
           DISPLAY "Vowels: " WS-VOWELS
           STOP RUN.

6. Name swap

Turn Lovelace, Ada into Ada Lovelace: split the input at ", " with UNSTRING, then join the parts with STRING.

Expected: [Ada Lovelace]

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. NAME-SWAP.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-INPUT           PIC X(30)   VALUE "Lovelace, Ada".
       01  WS-OUTPUT          PIC X(30)   VALUE SPACES.
       PROCEDURE DIVISION.
      *> TODO: UNSTRING into last and first name, then STRING them
           MOVE WS-INPUT TO WS-OUTPUT
           DISPLAY "[" FUNCTION TRIM(WS-OUTPUT) "]"
           STOP RUN.
[Lovelace, Ada]
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. NAME-SWAP.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-INPUT           PIC X(30)   VALUE "Lovelace, Ada".
       01  WS-LAST            PIC X(15).
       01  WS-FIRST           PIC X(15).
       01  WS-OUTPUT          PIC X(30)   VALUE SPACES.
       PROCEDURE DIVISION.
           UNSTRING WS-INPUT DELIMITED BY ", "
               INTO WS-LAST WS-FIRST
           END-UNSTRING
           STRING WS-FIRST DELIMITED BY SPACE
                  " "      DELIMITED BY SIZE
                  WS-LAST  DELIMITED BY SPACE
               INTO WS-OUTPUT
           END-STRING
           DISPLAY "[" FUNCTION TRIM(WS-OUTPUT) "]"
           STOP RUN.

7. Temperature statistics

A week of temperatures is stored as signed numbers with a separate leading sign (PIC S99 SIGN LEADING SEPARATE, three characters each such as -03). Find the maximum, the minimum and the average rounded to one decimal.

Expected: Max +21 min -03 average +11.3

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. TABLE-STATS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-TEMP-DATA       PIC X(21)
           VALUE "+12+15-03+08+21+17+09".
       01  WS-TEMPS REDEFINES WS-TEMP-DATA.
           05  WS-TEMP        PIC S99 SIGN LEADING SEPARATE
                              OCCURS 7 TIMES.
       01  WS-MAX             PIC S99     VALUE 0.
       01  WS-MIN             PIC S99     VALUE 0.
       01  WS-AVG             PIC S99V9   VALUE 0.
       PROCEDURE DIVISION.
      *> TODO: loop over the 7 temperatures
           DISPLAY "Max " WS-MAX " min " WS-MIN " average " WS-AVG
           STOP RUN.
Max +00 min +00 average +00.0
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. TABLE-STATS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-TEMP-DATA       PIC X(21)
           VALUE "+12+15-03+08+21+17+09".
       01  WS-TEMPS REDEFINES WS-TEMP-DATA.
           05  WS-TEMP        PIC S99 SIGN LEADING SEPARATE
                              OCCURS 7 TIMES.
       01  WS-I               PIC 9.
       01  WS-MAX             PIC S99.
       01  WS-MIN             PIC S99.
       01  WS-SUM             PIC S999    VALUE 0.
       01  WS-AVG             PIC S99V9.
       PROCEDURE DIVISION.
           MOVE WS-TEMP (1) TO WS-MAX WS-MIN
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 7
               ADD WS-TEMP (WS-I) TO WS-SUM
               IF WS-TEMP (WS-I) > WS-MAX
                   MOVE WS-TEMP (WS-I) TO WS-MAX
               END-IF
               IF WS-TEMP (WS-I) < WS-MIN
                   MOVE WS-TEMP (WS-I) TO WS-MIN
               END-IF
           END-PERFORM
           DIVIDE WS-SUM BY 7 GIVING WS-AVG ROUNDED
           DISPLAY "Max " WS-MAX " min " WS-MIN " average " WS-AVG
           STOP RUN.

8. Leap years

A year is a leap year if it is divisible by 4, except years divisible by 100, which are leap years only when also divisible by 400. Check 1900, 2000, 2024, 2025 and 2100, using a flag with the condition names IS-LEAP and NOT-LEAP.

Expected: 1900 is not a leap year, 2000 is a leap year, 2024 is a leap year, 2025 is not a leap year, 2100 is not a leap year.

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. LEAP-YEARS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-YEAR-DATA       PIC X(20)   VALUE "19002000202420252100".
       01  WS-YEARS REDEFINES WS-YEAR-DATA.
           05  WS-YEAR-ITEM   PIC 9(4)    OCCURS 5 TIMES.
       01  WS-I               PIC 9.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 5
      *> TODO: decide with FUNCTION MOD and print the right message
               DISPLAY WS-YEAR-ITEM (WS-I) " is ... "
           END-PERFORM
           STOP RUN.
1900 is ...
2000 is ...
2024 is ...
2025 is ...
2100 is ...
Show solution
cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. LEAP-YEARS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-YEAR-DATA       PIC X(20)   VALUE "19002000202420252100".
       01  WS-YEARS REDEFINES WS-YEAR-DATA.
           05  WS-YEAR-ITEM   PIC 9(4)    OCCURS 5 TIMES.
       01  WS-YEAR            PIC 9(4).
       01  WS-LEAP-FLAG       PIC X.
           88  IS-LEAP                    VALUE "Y".
           88  NOT-LEAP                   VALUE "N".
       01  WS-I               PIC 9.
       PROCEDURE DIVISION.
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 5
               MOVE WS-YEAR-ITEM (WS-I) TO WS-YEAR
               EVALUATE TRUE
                   WHEN FUNCTION MOD(WS-YEAR, 400) = 0
                       SET IS-LEAP TO TRUE
                   WHEN FUNCTION MOD(WS-YEAR, 100) = 0
                       SET NOT-LEAP TO TRUE
                   WHEN FUNCTION MOD(WS-YEAR, 4) = 0
                       SET IS-LEAP TO TRUE
                   WHEN OTHER
                       SET NOT-LEAP TO TRUE
               END-EVALUATE
               IF IS-LEAP
                   DISPLAY WS-YEAR " is a leap year"
               ELSE
                   DISPLAY WS-YEAR " is not a leap year"
               END-IF
           END-PERFORM
           STOP RUN.

Test yourself

In exercise 3, why does DIVIDE WS-CENTS BY WS-COIN (WS-I) GIVING WS-COUNT REMAINDER WS-CENTS work in a loop?

  1. It doesn't; REMAINDER cannot reuse the dividend
  2. The remainder becomes the new amount still to be paid out for the next, smaller coin
  3. Because DIVIDE rounds automatically
  4. Because WS-COUNT is a table

Why does the FizzBuzz solution test MOD(WS-N, 15) = 0 first?

  1. MOD only works with 15
  2. EVALUATE runs only the first true WHEN, so the most specific case must come first
  3. To make it faster
  4. It is not necessary