TExcelTAD
Home › COBOL › COBOL Subprograms (CALL)

COBOL Subprograms (CALL)

Large COBOL systems are made of many separately compiled programs. A program uses another one with CALL, passing data with USING. The called program (the subprogram) describes that data in its LINKAGE SECTION and returns with GOBACK.

cobol
      *> In the caller
           CALL "CALC-TAX" USING WS-GROSS WS-TAX

      *> In the subprogram
       LINKAGE SECTION.
       01  LK-GROSS           PIC 9(7)V99.
       01  LK-TAX             PIC 9(7)V99.
       PROCEDURE DIVISION USING LK-GROSS LK-TAX.

In real projects each program lives in its own file and is compiled separately (cobc -m calctax.cob builds a loadable module, found at run time through COB_LIBRARY_PATH). In the playground, both programs are written in one source file, each ending with END PROGRAM name.. GnuCOBOL compiles them together and CALL finds the second program.

A first CALL

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. PAYROLL.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-GROSS           PIC 9(7)V99 VALUE 3250.00.
       01  WS-TAX             PIC 9(7)V99.
       PROCEDURE DIVISION.
           CALL "CALC-TAX" USING WS-GROSS WS-TAX
           DISPLAY "Gross " WS-GROSS " tax " WS-TAX
           STOP RUN.
       END PROGRAM PAYROLL.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. CALC-TAX.
       DATA DIVISION.
       LINKAGE SECTION.
       01  LK-GROSS           PIC 9(7)V99.
       01  LK-TAX             PIC 9(7)V99.
       PROCEDURE DIVISION USING LK-GROSS LK-TAX.
           IF LK-GROSS > 2000
               COMPUTE LK-TAX ROUNDED = (LK-GROSS - 2000) * 0.22
           ELSE
               MOVE ZERO TO LK-TAX
           END-IF
           GOBACK.
       END PROGRAM CALC-TAX.
Gross 0003250.00 tax 0000275.00

The parameters are matched by position, not by name: the first item after USING in the CALL becomes the first item in the subprogram's PROCEDURE DIVISION USING. The names can differ (WS-GROSS / LK-GROSS), but the layouts must match, byte for byte. A mismatch is not detected and corrupts data.

BY REFERENCE, BY CONTENT, BY VALUE

Passing mode What the subprogram gets Can it change the caller's data?
BY REFERENCE (default) The address of the caller's item Yes
BY CONTENT The address of a temporary copy No
BY VALUE The value itself (for C-style interfaces) No
cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. PASSING-DEMO.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-A               PIC 9(3)    VALUE 10.
       01  WS-B               PIC 9(3)    VALUE 10.
       PROCEDURE DIVISION.
           CALL "ADD-HUNDRED" USING BY REFERENCE WS-A
           CALL "ADD-HUNDRED" USING BY CONTENT WS-B
           DISPLAY "By reference: " WS-A
           DISPLAY "By content:   " WS-B
           STOP RUN.
       END PROGRAM PASSING-DEMO.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. ADD-HUNDRED.
       DATA DIVISION.
       LINKAGE SECTION.
       01  LK-NUM             PIC 9(3).
       PROCEDURE DIVISION USING LK-NUM.
           ADD 100 TO LK-NUM
           DISPLAY "  inside: " LK-NUM
           GOBACK.
       END PROGRAM ADD-HUNDRED.
  inside: 110
  inside: 110
By reference: 110
By content:   010

Passing a record and returning a status

Real interfaces usually pass a single group item, often defined in a copybook so that caller and subprogram share the same layout, with a return code field inside:

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. ACCOUNT-CHECK.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-REQUEST.
           05  REQ-ACCOUNT        PIC 9(6).
           05  REQ-AMOUNT         PIC 9(5)V99.
           05  REQ-RETURN-CODE    PIC 99.
               88  REQ-OK                     VALUE 0.
               88  REQ-INVALID                VALUE 8.
       PROCEDURE DIVISION.
           MOVE 123456 TO REQ-ACCOUNT  MOVE 250.00 TO REQ-AMOUNT
           PERFORM SEND-REQUEST
           MOVE 000099 TO REQ-ACCOUNT
           PERFORM SEND-REQUEST
           STOP RUN.
       SEND-REQUEST.
           CALL "VALIDATE-ACCT" USING WS-REQUEST
           IF REQ-OK
               DISPLAY REQ-ACCOUNT ": accepted"
           ELSE
               DISPLAY REQ-ACCOUNT ": rejected, code " REQ-RETURN-CODE
           END-IF.
       END PROGRAM ACCOUNT-CHECK.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. VALIDATE-ACCT.
       DATA DIVISION.
       LINKAGE SECTION.
       01  LK-REQUEST.
           05  LK-ACCOUNT         PIC 9(6).
           05  LK-AMOUNT          PIC 9(5)V99.
           05  LK-RETURN-CODE     PIC 99.
       PROCEDURE DIVISION USING LK-REQUEST.
           IF LK-ACCOUNT < 100000
               MOVE 8 TO LK-RETURN-CODE
           ELSE
               MOVE 0 TO LK-RETURN-CODE
           END-IF
           GOBACK.
       END PROGRAM VALIDATE-ACCT.
123456: accepted
000099: rejected, code 08

WORKING-STORAGE keeps its values between calls

A subprogram's WORKING-STORAGE is initialised only on the first call and then keeps its values. That is useful for counters and caches, and surprising if you expect a fresh start. LOCAL-STORAGE is re-initialised on every call, and CANCEL "name" resets the whole subprogram:

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. STATE-DEMO.
       PROCEDURE DIVISION.
           CALL "COUNTER"
           CALL "COUNTER"
           CALL "COUNTER"
           CANCEL "COUNTER"
           CALL "COUNTER"
           STOP RUN.
       END PROGRAM STATE-DEMO.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. COUNTER.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-CALLS           PIC 99      VALUE 0.
       LOCAL-STORAGE SECTION.
       01  LS-CALLS           PIC 99      VALUE 0.
       PROCEDURE DIVISION.
           ADD 1 TO WS-CALLS LS-CALLS
           DISPLAY "working-storage " WS-CALLS
                   ", local-storage " LS-CALLS
           GOBACK.
       END PROGRAM COUNTER.
working-storage 01, local-storage 01
working-storage 02, local-storage 01
working-storage 03, local-storage 01
working-storage 01, local-storage 01

Static and dynamic calls

  • CALL "LITERAL" names the program directly. Depending on compiler options it is linked statically into the executable or loaded dynamically at run time.
  • CALL WS-PROGRAM-NAME with a data item is always dynamic: the program to run is chosen at run time, which is how menu-driven systems dispatch to many programs.
  • ON EXCEPTION handles a program that cannot be found:
cobol
           MOVE "RPT-MONTHLY" TO WS-PROGRAM-NAME
           CALL WS-PROGRAM-NAME USING WS-PARAMS
               ON EXCEPTION
                   DISPLAY "Program not found: " WS-PROGRAM-NAME
           END-CALL

Tip: RETURN-CODE is a special register. A subprogram can MOVE 4 TO RETURN-CODE before GOBACK, and the caller reads it after the CALL. In a main program, its value becomes the job's exit status (the condition code checked by JCL).

Test yourself

How are CALL parameters matched to the subprogram's LINKAGE items?

  1. By name
  2. By position
  3. By size
  4. By level number

Which passing mode protects the caller's data from changes?

  1. BY REFERENCE
  2. BY CONTENT
  3. BY ADDRESS
  4. BY NAME

What happens to a subprogram's WORKING-STORAGE between two CALLs?

  1. It is reset to its VALUE clauses
  2. It keeps the values from the previous call (until CANCEL)
  3. It is shared with the caller