TExcelTAD
Home › COBOL › COBOL Nested Programs

COBOL Nested Programs

Since COBOL-85, a program can contain other programs. A nested program is written inside its parent, before the parent's END PROGRAM. It works like a subprogram (it is invoked with CALL and has its own DATA DIVISION), but it is part of the same compilation unit and by default can only be called by its parent.

cobol
       IDENTIFICATION DIVISION.
       PROGRAM-ID. OUTER.
       ...
       PROCEDURE DIVISION.
           CALL "INNER"
           STOP RUN.

           IDENTIFICATION DIVISION.
           PROGRAM-ID. INNER.
           ...
           END PROGRAM INNER.
       END PROGRAM OUTER.

Nested programs give you private helper routines with their own local data, something that paragraphs cannot do.

A nested helper with parameters

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. INVOICE.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-NET             PIC 9(5)V99 VALUE 80.00.
       01  WS-GROSS           PIC 9(5)V99.
       PROCEDURE DIVISION.
           CALL "ADD-VAT" USING WS-NET WS-GROSS
           DISPLAY "Net " WS-NET " -> gross " WS-GROSS
           MOVE 19.99 TO WS-NET
           CALL "ADD-VAT" USING WS-NET WS-GROSS
           DISPLAY "Net " WS-NET " -> gross " WS-GROSS
           STOP RUN.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. ADD-VAT.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  VAT-RATE           PIC V99     VALUE .20.
       LINKAGE SECTION.
       01  LK-NET             PIC 9(5)V99.
       01  LK-GROSS           PIC 9(5)V99.
       PROCEDURE DIVISION USING LK-NET LK-GROSS.
           COMPUTE LK-GROSS ROUNDED = LK-NET * (1 + VAT-RATE)
           GOBACK.
       END PROGRAM ADD-VAT.

       END PROGRAM INVOICE.
Net 00080.00 -> gross 00096.00
Net 00019.99 -> gross 00023.99

VAT-RATE belongs to ADD-VAT alone: the outer program cannot see it, which keeps helper data private.

GLOBAL data

An item declared GLOBAL in the outer program is visible in every program nested inside it, without passing it as a parameter. Use it sparingly, for things like a shared error counter or configuration:

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. BATCH-RUN.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-ERROR-COUNT     PIC 99      VALUE 0   GLOBAL.
       01  WS-INPUT           PIC X(5).
       PROCEDURE DIVISION.
           MOVE "12345" TO WS-INPUT
           CALL "CHECK-FIELD" USING WS-INPUT
           MOVE "12A45" TO WS-INPUT
           CALL "CHECK-FIELD" USING WS-INPUT
           MOVE "9X9X9" TO WS-INPUT
           CALL "CHECK-FIELD" USING WS-INPUT
           DISPLAY "Errors found: " WS-ERROR-COUNT
           STOP RUN.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. CHECK-FIELD.
       DATA DIVISION.
       LINKAGE SECTION.
       01  LK-FIELD           PIC X(5).
       PROCEDURE DIVISION USING LK-FIELD.
           IF LK-FIELD IS NOT NUMERIC
               ADD 1 TO WS-ERROR-COUNT
               DISPLAY "Not numeric: " LK-FIELD
           END-IF
           GOBACK.
       END PROGRAM CHECK-FIELD.

       END PROGRAM BATCH-RUN.
Not numeric: 12A45
Not numeric: 9X9X9
Errors found: 02

COMMON programs

By default a nested program can only be called by the program that directly contains it. Declaring it IS COMMON lets its siblings (other programs nested in the same parent) call it as well. Here LOG-LINE is a shared helper used by both STEP-ONE and STEP-TWO:

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. JOB-MAIN.
       PROCEDURE DIVISION.
           CALL "STEP-ONE"
           CALL "STEP-TWO"
           STOP RUN.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. LOG-LINE IS COMMON.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-LINE-NO         PIC 99      VALUE 0.
       LINKAGE SECTION.
       01  LK-TEXT            PIC X(20).
       PROCEDURE DIVISION USING LK-TEXT.
           ADD 1 TO WS-LINE-NO
           DISPLAY WS-LINE-NO " | " LK-TEXT
           GOBACK.
       END PROGRAM LOG-LINE.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. STEP-ONE.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-MSG             PIC X(20)   VALUE "Step one started".
       PROCEDURE DIVISION.
           CALL "LOG-LINE" USING BY CONTENT WS-MSG
           GOBACK.
       END PROGRAM STEP-ONE.

       IDENTIFICATION DIVISION.
       PROGRAM-ID. STEP-TWO.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-MSG             PIC X(20)   VALUE "Step two started".
       PROCEDURE DIVISION.
           CALL "LOG-LINE" USING BY CONTENT WS-MSG
           GOBACK.
       END PROGRAM STEP-TWO.

       END PROGRAM JOB-MAIN.
01 | Step one started
02 | Step two started

Each step passes a 20-character item, exactly the layout LOG-LINE expects in its LINKAGE SECTION. Passing a shorter literal would be risky: the subprogram would still read 20 bytes. WS-LINE-NO keeps counting across both callers because LOG-LINE is one program with one WORKING-STORAGE.

Nested or separate?

Nested program Separately compiled subprogram
Source Inside the parent Its own file
Who can call it The parent (and siblings if COMMON) Any program
Shared data GLOBAL items, parameters Parameters only
Deployment Compiled with the parent Own module, can be replaced independently

Shops with large shared libraries usually prefer separate subprograms; nested programs are good for helpers that only one program needs.

Test yourself

Where is a nested program written?

  1. In a separate file
  2. Inside the containing program, before its END PROGRAM
  3. In the LINKAGE SECTION
  4. After the outer program's END PROGRAM

What does GLOBAL do on a data item?

  1. Makes it visible to all programs nested inside the declaring program
  2. Shares it with every program in the system
  3. Makes it a constant
  4. Stores it in a file

Why declare a nested program IS COMMON?

  1. To make it run faster
  2. So sibling nested programs can call it too
  3. To allow recursion
  4. To share its WORKING-STORAGE with the parent