TExcelTAD
Home › COBOL › COBOL USAGE (COMP, COMP-3)

COBOL USAGE (COMP, COMP-3)

The PICTURE clause says what values an item can hold. The USAGE clause says how those values are stored in memory. The default, USAGE DISPLAY, stores one character per digit, which is readable but slow for arithmetic. The other usages trade readability for speed and space.

Usage Also written Storage Typical use
DISPLAY (default) 1 byte per digit, as characters Records, printing, data exchange
BINARY COMP, COMP-4 Binary integer: 2, 4 or 8 bytes Counters, subscripts, lengths
PACKED-DECIMAL COMP-3 2 digits per byte + sign half-byte Money in mainframe files and DB2
COMP-5 Native binary, full range of the bytes Calling C or system APIs
COMP-1 / COMP-2 FLOAT-SHORT / FLOAT-LONG Floating point (4 / 8 bytes) Scientific values (rare)
INDEX Like an index Saving index values

Sizes in bytes

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. USAGE-SIZES.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-DISP            PIC S9(7)V99 VALUE 12345.67.
       01  WS-PACKED          PIC S9(7)V99 COMP-3 VALUE 12345.67.
       01  WS-BIN-4           PIC S9(4)   COMP  VALUE 1234.
       01  WS-BIN-9           PIC S9(9)   COMP  VALUE 123456789.
       01  WS-BIN-18          PIC S9(18)  COMP  VALUE 1.
       PROCEDURE DIVISION.
           DISPLAY "DISPLAY S9(7)V99: " FUNCTION LENGTH(WS-DISP)
                   " bytes, value " WS-DISP
           DISPLAY "COMP-3  S9(7)V99: " FUNCTION LENGTH(WS-PACKED)
                   " bytes, value " WS-PACKED
           DISPLAY "COMP    S9(4):    " FUNCTION LENGTH(WS-BIN-4)
                   " bytes"
           DISPLAY "COMP    S9(9):    " FUNCTION LENGTH(WS-BIN-9)
                   " bytes"
           DISPLAY "COMP    S9(18):   " FUNCTION LENGTH(WS-BIN-18)
                   " bytes"
           STOP RUN.
DISPLAY S9(7)V99: 9 bytes, value +0012345.67
COMP-3  S9(7)V99: 5 bytes, value +0012345.67
COMP    S9(4):    2 bytes
COMP    S9(9):    4 bytes
COMP    S9(18):   8 bytes

DISPLAY converts every usage back to readable digits, so the values look the same; only the storage differs.

How COMP-3 (packed decimal) works

Packed decimal stores two decimal digits in each byte (one per half-byte, or "nibble") and puts the sign in the last nibble: C for positive, D for negative, F for unsigned. +12345.67 in PIC S9(7)V99 COMP-3 is 9 digits, padded to an even count with a leading zero:

text
digits:   0 0 1 2 3 4 5 6 7  sign C
bytes:    00   12   34   56   7C        -> 5 bytes instead of 9

The size of a packed field is (digits + 1) / 2 bytes, rounded up. Mainframes have hardware instructions for packed arithmetic, which is why so much financial data is stored this way. You can see the raw bytes with FUNCTION HEX-OF (a GnuCOBOL extension):

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. PACKED-BYTES.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-POS             PIC S9(7)V99 COMP-3 VALUE 12345.67.
       01  WS-NEG             PIC S9(3)    COMP-3 VALUE -42.
       01  WS-TEXT-NUM        PIC 9(4)            VALUE 1234.
       PROCEDURE DIVISION.
           DISPLAY "+12345.67 packed: " FUNCTION HEX-OF(WS-POS)
           DISPLAY "-42 packed:       " FUNCTION HEX-OF(WS-NEG)
           DISPLAY "1234 as DISPLAY:  " FUNCTION HEX-OF(WS-TEXT-NUM)
           STOP RUN.
+12345.67 packed: 001234567C
-42 packed:       042D
1234 as DISPLAY:  31323334

In DISPLAY usage the digits are the ASCII characters 31 32 33 34 (on a mainframe they would be EBCDIC F1 F2 F3 F4).

Binary (COMP) and the PICTURE limit

A COMP item holds a binary integer, but by default COBOL still respects the number of digits in the picture. PIC S9(4) COMP can physically hold up to 32,767, yet the standard says values beyond 9,999 are truncated. GnuCOBOL follows that rule by default (-fbinary-truncate); IBM's TRUNC(BIN) option and COMP-5 use the full binary range:

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. BINARY-TRUNC.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-COMP            PIC S9(4) COMP   VALUE 9000.
       01  WS-COMP5           PIC S9(4) COMP-5 VALUE 9000.
       PROCEDURE DIVISION.
           ADD 3000 TO WS-COMP
           ADD 3000 TO WS-COMP5
           DISPLAY "COMP   9000 + 3000 = " WS-COMP
           DISPLAY "COMP-5 9000 + 3000 = " WS-COMP5
           STOP RUN.
COMP   9000 + 3000 = +2000
COMP-5 9000 + 3000 = +12000

With COMP the result 12000 lost its high-order digit and became 2000; COMP-5 kept it.

Choosing a usage

  • Counters, subscripts and loop variables: PIC S9(4) COMP or PIC S9(8) COMP (fast binary arithmetic).
  • Money and quantities in files and databases: COMP-3 on mainframes, or DISPLAY for portable text files.
  • Anything you print or exchange as text: DISPLAY, then edit it into a report field.
  • Avoid COMP-1/COMP-2 for money: they are binary floating point, with the same rounding issues as double in other languages.
cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. FLOAT-VS-DECIMAL.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-FLOAT           COMP-2      VALUE 0.
       01  WS-DECIMAL         PIC 9V99    VALUE 0.
       01  WS-I               PIC 99.
       01  WS-SHOW            PIC 9.9(17).
       PROCEDURE DIVISION.
           PERFORM VARYING WS-I FROM 1 BY 1 UNTIL WS-I > 10
               ADD 0.1 TO WS-FLOAT
               ADD 0.1 TO WS-DECIMAL
           END-PERFORM
           MOVE WS-FLOAT TO WS-SHOW
           DISPLAY "COMP-2 ten times 0.1:  " WS-SHOW
           DISPLAY "PIC 9V99 ten times 0.1: " WS-DECIMAL
           STOP RUN.
COMP-2 ten times 0.1:  0.99999999999999977
PIC 9V99 ten times 0.1: 1.00

Test yourself

How many bytes does PIC S9(5) COMP-3 occupy?

  1. 2
  2. 3
  3. 5
  4. 6

Which usage is best for a loop counter or subscript?

  1. DISPLAY
  2. COMP (binary)
  3. COMP-2
  4. COMP-3

What is the default usage of a numeric item?

  1. COMP
  2. COMP-3
  3. DISPLAY
  4. BINARY