COBOL File Status & File Types
Every file operation can fail: the file is missing, a disk is full, a key is duplicated. COBOL reports the outcome
of each OPEN, READ, WRITE, REWRITE and CLOSE in a two-character file status field that you name in the
SELECT entry. Checking it is what separates a robust batch program from one that silently produces wrong output.
Common file status codes
| Status | Meaning |
|---|---|
00 |
Success |
02 |
Success, duplicate alternate key (indexed files) |
04 |
Record length does not match the description |
05 |
OPEN of an OPTIONAL file that does not exist (the file is treated as empty) |
10 |
End of file |
22 |
Duplicate key on WRITE (indexed/relative files) |
23 |
Record not found (keyed READ) |
30 |
Permanent I/O error |
35 |
OPEN INPUT on a file that does not exist |
41 / 42 |
File already open / not open |
46 |
READ after end of file was already reached |
47 / 48 |
READ / WRITE not allowed in the current open mode |
The first character gives the class: 0 success, 1 end of file, 2 key problem, 3 permanent error, 4 logic
error in the program.
Checking the status
IDENTIFICATION DIVISION.
PROGRAM-ID. STATUS-CHECK.
ENVIRONMENT DIVISION.
INPUT-OUTPUT SECTION.
FILE-CONTROL.
SELECT MISSING-FILE ASSIGN TO "no-such-file.dat"
ORGANIZATION IS LINE SEQUENTIAL
FILE STATUS IS WS-STATUS.
DATA DIVISION.
FILE SECTION.
FD MISSING-FILE.
01 MISSING-RECORD PIC X(20).
WORKING-STORAGE SECTION.
01 WS-STATUS PIC XX.
88 STATUS-OK VALUE "00".
88 STATUS-NOT-FOUND VALUE "35".
PROCEDURE DIVISION.
OPEN INPUT MISSING-FILE
EVALUATE TRUE
WHEN STATUS-OK
DISPLAY "File opened"
CLOSE MISSING-FILE
WHEN STATUS-NOT-FOUND
DISPLAY "Input file is missing (status 35)"
WHEN OTHER
DISPLAY "Unexpected status " WS-STATUS
END-EVALUATE
READ MISSING-FILE
AT END DISPLAY "at end"
END-READ
DISPLAY "READ on a file that is not open: " WS-STATUS
STOP RUN.Input file is missing (status 35)
READ on a file that is not open: 47
The READ after the failed OPEN returns 47: the file is not open for input, so reading is not allowed.
When a FILE STATUS clause is present, an I/O error does not stop the program: it is your job to look at the
status. Without the clause (and without a USE declarative), GnuCOBOL stops the run with an error message on
most failures.
Updating records in place with REWRITE
A file opened I-O can be read and its records changed with REWRITE, which replaces the record that was just
read. For sequential files the record length must stay the same. Here every balance gets 2% interest:
IDENTIFICATION DIVISION.
PROGRAM-ID. REWRITE-DEMO.
ENVIRONMENT DIVISION.
INPUT-OUTPUT SECTION.
FILE-CONTROL.
SELECT ACCOUNTS ASSIGN TO "accounts.dat"
ORGANIZATION IS SEQUENTIAL
FILE STATUS IS WS-STATUS.
DATA DIVISION.
FILE SECTION.
FD ACCOUNTS.
01 ACCOUNT-RECORD.
05 ACC-NUMBER PIC 9(4).
05 ACC-BALANCE PIC 9(6)V99.
WORKING-STORAGE SECTION.
01 WS-STATUS PIC XX.
01 WS-EOF PIC X VALUE "N".
PROCEDURE DIVISION.
OPEN OUTPUT ACCOUNTS
MOVE 1 TO ACC-NUMBER MOVE 1000.00 TO ACC-BALANCE
WRITE ACCOUNT-RECORD
MOVE 2 TO ACC-NUMBER MOVE 250.50 TO ACC-BALANCE
WRITE ACCOUNT-RECORD
CLOSE ACCOUNTS
OPEN I-O ACCOUNTS
PERFORM UNTIL WS-EOF = "Y"
READ ACCOUNTS
AT END MOVE "Y" TO WS-EOF
NOT AT END
COMPUTE ACC-BALANCE ROUNDED = ACC-BALANCE * 1.02
REWRITE ACCOUNT-RECORD
DISPLAY "Rewrote " ACC-NUMBER ": " ACC-BALANCE
" status " WS-STATUS
END-READ
END-PERFORM
CLOSE ACCOUNTS
STOP RUN.Rewrote 0001: 001020.00 status 00
Rewrote 0002: 000255.51 status 00
This file uses plain ORGANIZATION IS SEQUENTIAL: fixed-length 12-byte records with no newlines, the format of
most mainframe data sets.
File organisations
| Organisation | Access | Like |
|---|---|---|
SEQUENTIAL |
In order only | A tape or a flat file |
LINE SEQUENTIAL |
In order, text lines (extension) | A text file |
RELATIVE |
By record number, or in order | An array on disk |
INDEXED |
By key, or in key order | A keyed table, like a simple database (VSAM KSDS on a mainframe) |
Indexed files need an indexing library at run time. The GnuCOBOL build on the playground has none, so indexed examples are shown here without a Run button. On your own machine, GnuCOBOL built with Berkeley DB or VBISAM runs them as written:
SELECT CUSTOMER-MASTER ASSIGN TO "custmast.idx"
ORGANIZATION IS INDEXED
ACCESS MODE IS DYNAMIC
RECORD KEY IS CM-CUST-ID
ALTERNATE RECORD KEY IS CM-NAME WITH DUPLICATES
FILE STATUS IS WS-CM-STATUS.
*> ...
MOVE 1002 TO CM-CUST-ID
READ CUSTOMER-MASTER
INVALID KEY
DISPLAY "Customer 1002 not found"
NOT INVALID KEY
DISPLAY "Found " CM-NAME
END-READ
MOVE 1000 TO CM-CUST-ID
START CUSTOMER-MASTER KEY IS >= CM-CUST-ID
READ CUSTOMER-MASTER NEXT RECORD
AT END SET END-OF-FILE TO TRUE
END-READACCESS MODEisSEQUENTIAL,RANDOM(by key) orDYNAMIC(both).READ … INVALID KEYhandles a key that does not exist (status23).STARTpositions the file at a key;READ … NEXTthen reads forward in key order.WRITE,REWRITEandDELETEwork by key; a duplicate key onWRITEgives status22.
Error handling with declaratives
Instead of checking the status after every statement, a program can define a DECLARATIVES section with
USE AFTER ERROR PROCEDURE ON file. It runs automatically when an I/O error occurs on that file:
PROCEDURE DIVISION.
DECLARATIVES.
CUSTOMER-ERROR SECTION.
USE AFTER STANDARD ERROR PROCEDURE ON CUSTOMER-FILE.
DISPLAY "I/O error on CUSTOMER-FILE, status " WS-CUST-STATUS
MOVE 16 TO RETURN-CODE.
END DECLARATIVES.
MAIN-LOGIC SECTION.
...Test yourself
What does file status 35 mean?
- End of file
- Duplicate key
- OPEN INPUT on a file that does not exist
- Success
What does file status 10 mean after a READ?
- Record not found
- End of file reached
- Permanent error
- Success
Which statement replaces the record just read from a file opened I-O?
- WRITE
- UPDATE
- REWRITE
- REPLACE