TExcelTAD
Home › COBOL › COBOL MOVE

COBOL MOVE

MOVE is COBOL's assignment statement. It copies a value into one or more receiving items:

cobol
           MOVE source TO target-1 [target-2 ...]

The interesting part is what happens when the source and the receiver have different sizes or types. COBOL never fails here: it pads or truncates according to fixed rules. Learning these rules is essential.

Alphanumeric moves: left-aligned

When the receiver is alphanumeric (PIC X), characters are copied from the left. A shorter value is padded with spaces on the right; a longer value is cut off on the right.

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. MOVE-TEXT.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-SHORT       PIC X(4).
       01  WS-LONG        PIC X(12).
       PROCEDURE DIVISION.
           MOVE "Amsterdam" TO WS-SHORT WS-LONG
           DISPLAY "X(4):  [" WS-SHORT "]"
           DISPLAY "X(12): [" WS-LONG "]"
           STOP RUN.
X(4):  [Amst]
X(12): [Amsterdam   ]

Numeric moves: aligned on the decimal point

When the receiver is numeric, the value is aligned on the decimal point. Integer digits that don't fit are lost from the left (the most significant digits!), missing positions become zeros, and extra decimals are cut off on the right (not rounded).

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. MOVE-NUM.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-SOURCE      PIC 9(5)V999 VALUE 12345.678.
       01  WS-SMALL       PIC 999V9.
       01  WS-BIG         PIC 9(7)V9(4).
       01  WS-WHOLE       PIC 9(5).
       PROCEDURE DIVISION.
           MOVE WS-SOURCE TO WS-SMALL WS-BIG WS-WHOLE
           DISPLAY "Source:     " WS-SOURCE
           DISPLAY "999V9:      " WS-SMALL
           DISPLAY "9(7)V9(4):  " WS-BIG
           DISPLAY "9(5):       " WS-WHOLE
           STOP RUN.
Source:     12345.678
999V9:      345.6
9(7)V9(4):  0012345.6780
9(5):       12345

12345.678 moved into 999V9 keeps 345.6: the 12 on the left and the 78 on the right are dropped without any warning.

Warning: Silent high-order truncation is a classic source of production bugs. Size receiving fields for the largest value the business allows, and use ON SIZE ERROR in arithmetic (later lesson) to catch overflows.

Mixing numbers and text

Move Result
numeric → alphanumeric The digits are copied as text, left-aligned (the sign is not copied)
alphanumeric → numeric The characters are treated as an unsigned integer; non-digits give garbage. Use FUNCTION NUMVAL instead
numeric → numeric-edited The value is formatted (see edited pictures)
group → anything A plain byte copy, as alphanumeric
cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. MOVE-MIXED.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-QTY         PIC 9(4)     VALUE 75.
       01  WS-QTY-TEXT    PIC X(6).
       01  WS-INPUT       PIC X(3)     VALUE "042".
       01  WS-NUMBER      PIC 9(3).
       PROCEDURE DIVISION.
           MOVE WS-QTY TO WS-QTY-TEXT
           DISPLAY "Number as text: [" WS-QTY-TEXT "]"
           MOVE WS-INPUT TO WS-NUMBER
           ADD 1 TO WS-NUMBER
           DISPLAY "Text as number + 1: " WS-NUMBER
           STOP RUN.
Number as text: [0075  ]
Text as number + 1: 043

Moving literals and figurative constants

cobol · try it yourself
       IDENTIFICATION DIVISION.
       PROGRAM-ID. MOVE-LITERALS.
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  WS-STATUS      PIC X(8)     VALUE "OPEN".
       01  WS-TOTAL       PIC S9(5)V99 VALUE 812.40.
       01  WS-CODE        PIC X(5).
       PROCEDURE DIVISION.
           MOVE "CLOSED" TO WS-STATUS
           MOVE ZERO TO WS-TOTAL
           MOVE ALL "#" TO WS-CODE
           DISPLAY WS-STATUS "|" WS-TOTAL "|" WS-CODE
           MOVE -3.456 TO WS-TOTAL
           DISPLAY "After MOVE -3.456: " WS-TOTAL
           STOP RUN.
CLOSED  |+00000.00|#####
After MOVE -3.456: -00003.45

Notice that -3.456 became -3.45: the third decimal was truncated, not rounded. Use COMPUTE … ROUNDED when you need rounding.

Common mistakes

  • Expecting MOVE to round. It truncates. Use ROUNDED with arithmetic.
  • Moving a signed value into an unsigned field: the sign is lost.
  • Moving text with letters into a numeric field and then calculating with it.
  • Forgetting that MOVE A TO B copies from A to B (the opposite order to b = a in other languages).

Test yourself

What does MOVE "Amsterdam" TO WS-CITY store if WS-CITY is PIC X(4)?

  1. "dam "
  2. "Amst"
  3. "Amsterdam"
  4. A runtime error

What does MOVE 12345 TO WS-N store if WS-N is PIC 999?

  1. 123
  2. 345
  3. 999
  4. 12345

Does MOVE 2.718 TO WS-X with WS-X PIC 9V99 round the value?

  1. Yes, it stores 2.72
  2. No, it stores 2.71
  3. It stores 3
  4. It is a compile error