Above a few hundred watts, single-switch converters run out of breath. The flyback stores too much energy, and the forward converter wastes half its core's flux swing while its switch blocks twice the input. Bridge converters fix both: two switches (half bridge) or four (full bridge) apply +V+V and −V-V to the transformer in turn, the core swings in both directions, and every switch is clamped to the input rail. They power servers, telecom rectifiers, electric-vehicle chargers and welders. Add a resonant tank and the switches can turn on at zero voltage. That is the LLC converter, which dominates efficient isolated supplies in 2026, from adapters and TV supplies above about 100 W100\ \text{W} to data-centre power shelves (smaller adapters are mostly flybacks).

Half bridge and full bridge

A half bridge has two switches in series across VinV_\text{in} and a capacitive divider (or one DC-blocking capacitor), so the primary sees ±Vin/2\pm V_\text{in}/2. A full bridge has two legs and applies ±Vin\pm V_\text{in}. Each switch blocks only VinV_\text{in} either way. With a centre-tapped or full-bridge rectifier and an output inductor, both are buck-derived like the push-pull of Forward and Push-Pull Converters. If each diagonal conducts for DTsDT_s per half-period (D≤0.5D \le 0.5):

Vout,half=D Vinn,Vout,full=2D VinnV_\text{out,half} = \frac{D\,V_\text{in}}{n}, \qquad V_\text{out,full} = \frac{2D\,V_\text{in}}{n}

The half bridge's series capacitor blocks any DC component, so flux walking cannot build up. A full bridge needs current-mode control or a blocking capacitor for the same reason. The phase-shifted full bridge keeps every switch at 50 % duty and shifts the timing of the two legs. The transformer's leakage inductance then swings each switch node over before the next switch turns on, which gives zero-voltage switching over most of the load range. All of these need dead time between the two switches of a leg (Gate Drivers).

The LLC resonant converter

+ Vin 24 V S1 S2 sw Cr 100 nF Lr 10 uH Lm 50 uH 1 : 1 diodebridge Co 47 uF, R 24 Ohm out

The half bridge drives a square wave at 50 % duty into a series tank: resonant capacitor CrC_r, resonant inductor LrL_r (often the transformer's leakage) and the magnetising inductance LmL_m (deliberately small, made with a gapped core). Power is controlled by frequency, not duty cycle. The series resonance sets the operating point where the gain is exactly one:

fr=12πLrCr,Rac=8n2π2R,Q=Lr/CrRac,Ln=LmLrf_r = \frac{1}{2\pi\sqrt{L_r C_r}}, \qquad R_\text{ac} = \frac{8 n^2}{\pi^2} R, \qquad Q = \frac{\sqrt{L_r/C_r}}{R_\text{ac}}, \qquad L_n = \frac{L_m}{L_r}

In the first-harmonic approximation (FHA), the square wave is replaced by its fundamental and the rectifier plus load by the resistor RacR_\text{ac}. With fn=fsw/frf_n = f_{sw}/f_r, the gain from the half-bridge's Vin/2V_\text{in}/2 to nVoutnV_\text{out} is:

M(fn)=∣Lnfn2[(Ln+1)fn2−1]+j (fn2−1) fn Q Ln∣M(f_n) = \left\lvert \frac{L_n f_n^2}{\left[(L_n + 1) f_n^2 - 1\right] + j\,(f_n^2 - 1)\, f_n\, Q\, L_n} \right\rvert

At fn=1f_n = 1, M=1M = 1 for any load, so an LLC designed to sit at resonance at nominal input is load-independent there. Below resonance, LmL_m joins the resonance and the gain rises, which covers low input (hold-up after a mains dropout). Above resonance the gain falls below one. As long as the tank looks inductive, the current lags the voltage, it discharges the switch-node capacitance during the dead time, and every switch turns on at zero voltage (ZVS). The rectifier diodes also turn off softly near resonance. That is why LLC stages reach 97 to 98 % efficiency.

Worked example: a low-voltage LLC

Given: half-bridge LLC from Vin=24 VV_\text{in} = 24\ \text{V}, Lr=10 μHL_r = 10\ \mu\text{H}, Cr=100 nFC_r = 100\ \text{nF}, Lm=50 μHL_m = 50\ \mu\text{H}, n=1n = 1, full-bridge rectifier, load R=24 ΩR = 24\ \Omega.

Find: frf_r, RacR_\text{ac}, QQ, LnL_n and the FHA output voltage at 120 kHz120\ \text{kHz}, frf_r and 200 kHz200\ \text{kHz} (ideal diodes).

Solve:

fr=12π10 μH⋅100 nF=159.2 kHz,Rac=8π2⋅24 Ω=19.45 ΩQ=10 μH/100 nF19.45 Ω=10 Ω19.45 Ω=0.514,Ln=5Vout=M⋅Vin2n=1.114⋅12=13.37 V,12.00 V,0.910⋅12=10.92 V\begin{aligned} f_r &= \frac{1}{2\pi\sqrt{10\ \mu\text{H} \cdot 100\ \text{nF}}} = 159.2\ \text{kHz}, \qquad R_\text{ac} = \frac{8}{\pi^2} \cdot 24\ \Omega = 19.45\ \Omega \\ Q &= \frac{\sqrt{10\ \mu\text{H}/100\ \text{nF}}}{19.45\ \Omega} = \frac{10\ \Omega}{19.45\ \Omega} = 0.514, \qquad L_n = 5 \\ V_\text{out} &= M \cdot \frac{V_\text{in}}{2n} = 1.114 \cdot 12 = 13.37\ \text{V},\quad 12.00\ \text{V},\quad 0.910 \cdot 12 = 10.92\ \text{V} \end{aligned}

Check: gain above one below resonance, one at resonance, below one above it, as the theory says. The characteristic impedance Lr/Cr=10 Ω\sqrt{L_r/C_r} = 10\ \Omega sets how hard the tank is loaded.

python · try it yourself
import numpy as np

Lr, Cr, Lm, n, R, Vin = 10e-6, 100e-9, 50e-6, 1.0, 24.0, 24.0
fr = 1 / (2 * np.pi * np.sqrt(Lr * Cr))
Rac = 8 * n**2 * R / np.pi**2
Z0 = np.sqrt(Lr / Cr)
Ln = Lm / Lr

def gain(fn, Q):
    return abs(Ln * fn**2 / (((Ln + 1) * fn**2 - 1) + 1j * (fn**2 - 1) * fn * Q * Ln))

print(f"fr = {fr/1e3:.1f} kHz, Rac = {Rac:.2f} ohm, Z0 = {Z0:.1f} ohm, Ln = {Ln:.0f}")
print("   load    Q    M(120k)  M(fr)  M(200k)  peak M (at f)")
fn = np.linspace(0.3, 2.0, 3401)
for Rl in (12.0, 24.0, 48.0, 240.0):
    Q = Z0 / (8 * n**2 * Rl / np.pi**2)
    M = gain(fn, Q)
    k = int(np.argmax(M))
    print(f"{Rl:6.0f} ohm {Q:5.3f} {gain(120e3/fr, Q):8.3f} {gain(1.0, Q):6.3f} {gain(200e3/fr, Q):8.3f}"
          f"   {M[k]:.3f} ({fn[k]*fr/1e3:.0f} kHz)")
Q = Z0 / Rac
for f in (120e3, fr, 200e3):
    print(f"f = {f/1e3:5.1f} kHz: FHA Vout = {gain(f/fr, Q) * Vin / (2 * n):.2f} V")
fr = 159.2 kHz, Rac = 19.45 ohm, Z0 = 10.0 ohm, Ln = 5
   load    Q    M(120k)  M(fr)  M(200k)  peak M (at f)
    12 ohm 1.028    0.969  1.000    0.852   1.023 (142 kHz)
    24 ohm 0.514    1.114  1.000    0.910   1.185 (91 kHz)
    48 ohm 0.257    1.162  1.000    0.926   2.001 (70 kHz)
   240 ohm 0.051    1.178  1.000    0.931   9.548 (65 kHz)
f = 120.0 kHz: FHA Vout = 13.37 V
f = 159.2 kHz: FHA Vout = 12.00 V
f = 200.0 kHz: FHA Vout = 10.92 V

The table shows the LLC's personality. Every load curve passes through M=1M = 1 at frf_r. Light loads (small QQ) give a tall gain peak below resonance, heavy loads a low one. The peak sets the lowest input voltage the converter can still regulate at full load. Above resonance a light load hardly lowers the gain, so regulating at no load needs a high frequency or burst mode.

Cross-check in ngspice

The deck builds the circuit of the figure: two ideal switches with body diodes, gates at 50 % with 100 ns100\ \text{ns} of dead time, the tank, a coupled 1:1 transformer whose 50 μH50\ \mu\text{H} primary is LmL_m, and Schottky diodes. It runs the same circuit at three frequencies.

bash · try it yourself
for f in 120 159.2 200; do
T=$(awk -v f=$f 'BEGIN{printf "%.5gu", 1000/f}')
H=$(awk -v f=$f 'BEGIN{printf "%.5gu", 1000/f/2-0.1}')
D=$(awk -v f=$f 'BEGIN{printf "%.5gu", 1000/f/2}')
cat > llc.cir <<EOF
* half-bridge LLC from 24 V: Lr 10u, Cr 100n, Lm 50u, 1:1, full-bridge rectifier, 24 ohm
.model SW SW(Ron=0.05 Roff=1meg Vt=2.5 Vh=0)
.model DB D(Is=1n N=1.5 Rs=0.02 Cjo=50p)
.model DS D(Is=2u N=1.05 Rs=0.02 Cjo=200p)
VIN vin 0 24
VG1 g1 0 PULSE(0 5 0 10n 10n $H $T)
VG2 g2 0 PULSE(0 5 $D 10n 10n $H $T)
S1 vin sw g1 0 SW
S2 sw 0 g2 0 SW
DB1 sw vin DB
DB2 0 sw DB
CR sw a 100n
LR a b 10u
LP b 0 50u
LS s1 s2 50u
K1 LP LS 0.9999
D1 s1 out DS
D2 s2 out DS
D3 0 s1 DS
D4 0 s2 DS
CO out 0 47u
RL out 0 24
.control
tran 10n 3m 0 10n
meas tran vout avg v(out) from=2.5m to=3m
meas tran ipk max i(LR) from=2.9m to=3m
.endc
.end
EOF
echo "f = $f kHz"
ngspice -b llc.cir 2>&1 | grep -E '^(vout|ipk) +='
done
f = 120 kHz
vout                =  1.351023e+01 from=  2.500000e-03 to=  3.000000e-03
ipk                 =  1.241484e+00 at=  2.993476e-03
f = 159.2 kHz
vout                =  1.126951e+01 from=  2.500000e-03 to=  3.000000e-03
ipk                 =  8.045253e-01 at=  2.991838e-03
f = 200 kHz
vout                =  9.954284e+00 from=  2.500000e-03 to=  3.000000e-03
ipk                 =  6.769465e-01 at=  2.961902e-03

SPICE gives 13.51 V13.51\ \text{V}, 11.27 V11.27\ \text{V} and 9.95 V9.95\ \text{V}. At resonance the result is the FHA's 12 V12\ \text{V} minus two diode drops of about 0.36 V0.36\ \text{V}. Away from resonance the FHA misses by a few percent, because the real current is not sinusoidal there. Designers use the FHA to choose LnL_n and QQ, then check with simulation. The tank current peaks at 1.24 A1.24\ \text{A} at 120 kHz120\ \text{kHz} and 0.80 A0.80\ \text{A} at resonance: running below resonance costs circulating current.

Guided lab

Hand calculation. For your tank values: frf_r, QQ at full and half load, and the FHA gain at the frequencies you plan to test.

Simulation. Run the Python cell with your load range. In the deck, change RL to 12 and to 240 ohm and compare with the table.

What you would measure. Use an LLC or full-bridge evaluation board specified for an input of 24 V or less (low-voltage LLC boards exist for bus converters and education), from a current-limited supply. Sweep the frequency (or let the controller do it while you change the load) and plot VoutV_\text{out} against fswf_{sw}: expect the curve to pass close to Vin/(2n)V_\text{in}/(2n) minus the diode drops at frf_r, within the tolerance of LrL_r and CrC_r (5 to 10 % on frf_r). Probe the switch node: with ZVS its edges are clean slopes that finish before the gate turns on. Below the gain peak (the capacitive region) you would see hard, ringing edges. Stop there: that region destroys MOSFETs at high voltage.

Hazards and safe setup. Resonant tanks build up voltages well above the input: the voltage across CrC_r swings by Ipk/(2πfCr)I_{pk}/(2\pi f C_r), about ±8 V\pm 8\ \text{V} here and hundreds of volts in a mains design. Keep the supply at 24 V24\ \text{V} or less and current-limited, and use rated probes. The transformer and rectifiers get hot. Off-line LLC supplies run from a 400 V400\ \text{V} PFC bus: calculation and simulation only; never open or build one.

Pitfalls

  • Operating in the capacitive region (below the gain peak): ZVS is lost and the body diodes are hard-recovered.
  • Trusting FHA far from resonance. It is a design-start tool; simulate the final design.
  • Forgetting the dead time a ZVS bridge needs. It must be long enough for the magnetising current to swing the switch node.
  • Ignoring the half bridge's capacitor-divider balance. Mismatched capacitors or unequal pulses shift the midpoint.

Practice

  1. A full bridge on a 400 V400\ \text{V} bus with n=16n = 16 (calculation only) runs at D=0.4D = 0.4 per half-period. Find VoutV_\text{out}.
  2. An LLC has Lr=20 μHL_r = 20\ \mu\text{H}, Cr=47 nFC_r = 47\ \text{nF}. Find frf_r and Lr/Cr\sqrt{L_r/C_r}.
  3. In the worked example, the load is doubled to 48 Ω48\ \Omega. Find QQ.
Answer
  1. Vout=2⋅0.4⋅400/16=20 VV_\text{out} = 2 \cdot 0.4 \cdot 400/16 = 20\ \text{V}.
  2. fr=1/(2π20×10−6⋅47×10−9)=164.2 kHzf_r = 1/(2\pi\sqrt{20 \times 10^{-6} \cdot 47 \times 10^{-9}}) = 164.2\ \text{kHz}; Lr/Cr=20.6 Ω\sqrt{L_r/C_r} = 20.6\ \Omega.
  3. Rac=8⋅48/π2=38.9 ΩR_\text{ac} = 8 \cdot 48/\pi^2 = 38.9\ \Omega, Q=10/38.9=0.257Q = 10/38.9 = 0.257.

Test yourself

What voltage does each switch of a half bridge or full bridge block?

  1. Vin/2V_\text{in}/2
  2. VinV_\text{in}
  3. 2Vin2V_\text{in}
  4. Vin+nVoutV_\text{in} + nV_\text{out}

How is the output of an LLC converter regulated?

  1. By the duty cycle
  2. By the switching frequency, which moves the operating point along the tank's gain curve
  3. By the turns ratio at run time
  4. By the dead time

At the series resonance frf_r, the FHA gain of an LLC is…

  1. zero
  2. one, independent of the load
  3. the peak gain
  4. LnL_n

Why must an LLC stay on the inductive side of its gain peak?

  1. To reduce the output ripple
  2. So the tank current lags and discharges the switch node in the dead time, giving zero-voltage turn-on
  3. To keep the frequency low