Half- and Full-Bridge Converters and the LLC Resonant Converter
Above a few hundred watts, single-switch converters run out of breath. The flyback stores too much energy, and the forward converter wastes half its core's flux swing while its switch blocks twice the input. Bridge converters fix both: two switches (half bridge) or four (full bridge) apply and to the transformer in turn, the core swings in both directions, and every switch is clamped to the input rail. They power servers, telecom rectifiers, electric-vehicle chargers and welders. Add a resonant tank and the switches can turn on at zero voltage. That is the LLC converter, which dominates efficient isolated supplies in 2026, from adapters and TV supplies above about to data-centre power shelves (smaller adapters are mostly flybacks).
Half bridge and full bridge
A half bridge has two switches in series across and a capacitive divider (or one DC-blocking capacitor), so the primary sees . A full bridge has two legs and applies . Each switch blocks only either way. With a centre-tapped or full-bridge rectifier and an output inductor, both are buck-derived like the push-pull of Forward and Push-Pull Converters. If each diagonal conducts for per half-period ():
The half bridge's series capacitor blocks any DC component, so flux walking cannot build up. A full bridge needs current-mode control or a blocking capacitor for the same reason. The phase-shifted full bridge keeps every switch at 50 % duty and shifts the timing of the two legs. The transformer's leakage inductance then swings each switch node over before the next switch turns on, which gives zero-voltage switching over most of the load range. All of these need dead time between the two switches of a leg (Gate Drivers).
The LLC resonant converter
The half bridge drives a square wave at 50 % duty into a series tank: resonant capacitor , resonant inductor (often the transformer's leakage) and the magnetising inductance (deliberately small, made with a gapped core). Power is controlled by frequency, not duty cycle. The series resonance sets the operating point where the gain is exactly one:
In the first-harmonic approximation (FHA), the square wave is replaced by its fundamental and the rectifier plus load by the resistor . With , the gain from the half-bridge's to is:
At , for any load, so an LLC designed to sit at resonance at nominal input is load-independent there. Below resonance, joins the resonance and the gain rises, which covers low input (hold-up after a mains dropout). Above resonance the gain falls below one. As long as the tank looks inductive, the current lags the voltage, it discharges the switch-node capacitance during the dead time, and every switch turns on at zero voltage (ZVS). The rectifier diodes also turn off softly near resonance. That is why LLC stages reach 97 to 98 % efficiency.
Worked example: a low-voltage LLC
Given: half-bridge LLC from , , , , , full-bridge rectifier, load .
Find: , , , and the FHA output voltage at , and (ideal diodes).
Solve:
Check: gain above one below resonance, one at resonance, below one above it, as the theory says. The characteristic impedance sets how hard the tank is loaded.
import numpy as np
Lr, Cr, Lm, n, R, Vin = 10e-6, 100e-9, 50e-6, 1.0, 24.0, 24.0
fr = 1 / (2 * np.pi * np.sqrt(Lr * Cr))
Rac = 8 * n**2 * R / np.pi**2
Z0 = np.sqrt(Lr / Cr)
Ln = Lm / Lr
def gain(fn, Q):
return abs(Ln * fn**2 / (((Ln + 1) * fn**2 - 1) + 1j * (fn**2 - 1) * fn * Q * Ln))
print(f"fr = {fr/1e3:.1f} kHz, Rac = {Rac:.2f} ohm, Z0 = {Z0:.1f} ohm, Ln = {Ln:.0f}")
print(" load Q M(120k) M(fr) M(200k) peak M (at f)")
fn = np.linspace(0.3, 2.0, 3401)
for Rl in (12.0, 24.0, 48.0, 240.0):
Q = Z0 / (8 * n**2 * Rl / np.pi**2)
M = gain(fn, Q)
k = int(np.argmax(M))
print(f"{Rl:6.0f} ohm {Q:5.3f} {gain(120e3/fr, Q):8.3f} {gain(1.0, Q):6.3f} {gain(200e3/fr, Q):8.3f}"
f" {M[k]:.3f} ({fn[k]*fr/1e3:.0f} kHz)")
Q = Z0 / Rac
for f in (120e3, fr, 200e3):
print(f"f = {f/1e3:5.1f} kHz: FHA Vout = {gain(f/fr, Q) * Vin / (2 * n):.2f} V")fr = 159.2 kHz, Rac = 19.45 ohm, Z0 = 10.0 ohm, Ln = 5
load Q M(120k) M(fr) M(200k) peak M (at f)
12 ohm 1.028 0.969 1.000 0.852 1.023 (142 kHz)
24 ohm 0.514 1.114 1.000 0.910 1.185 (91 kHz)
48 ohm 0.257 1.162 1.000 0.926 2.001 (70 kHz)
240 ohm 0.051 1.178 1.000 0.931 9.548 (65 kHz)
f = 120.0 kHz: FHA Vout = 13.37 V
f = 159.2 kHz: FHA Vout = 12.00 V
f = 200.0 kHz: FHA Vout = 10.92 V
The table shows the LLC's personality. Every load curve passes through at . Light loads (small ) give a tall gain peak below resonance, heavy loads a low one. The peak sets the lowest input voltage the converter can still regulate at full load. Above resonance a light load hardly lowers the gain, so regulating at no load needs a high frequency or burst mode.
Cross-check in ngspice
The deck builds the circuit of the figure: two ideal switches with body diodes, gates at 50 % with of dead time, the tank, a coupled 1:1 transformer whose primary is , and Schottky diodes. It runs the same circuit at three frequencies.
for f in 120 159.2 200; do
T=$(awk -v f=$f 'BEGIN{printf "%.5gu", 1000/f}')
H=$(awk -v f=$f 'BEGIN{printf "%.5gu", 1000/f/2-0.1}')
D=$(awk -v f=$f 'BEGIN{printf "%.5gu", 1000/f/2}')
cat > llc.cir <<EOF
* half-bridge LLC from 24 V: Lr 10u, Cr 100n, Lm 50u, 1:1, full-bridge rectifier, 24 ohm
.model SW SW(Ron=0.05 Roff=1meg Vt=2.5 Vh=0)
.model DB D(Is=1n N=1.5 Rs=0.02 Cjo=50p)
.model DS D(Is=2u N=1.05 Rs=0.02 Cjo=200p)
VIN vin 0 24
VG1 g1 0 PULSE(0 5 0 10n 10n $H $T)
VG2 g2 0 PULSE(0 5 $D 10n 10n $H $T)
S1 vin sw g1 0 SW
S2 sw 0 g2 0 SW
DB1 sw vin DB
DB2 0 sw DB
CR sw a 100n
LR a b 10u
LP b 0 50u
LS s1 s2 50u
K1 LP LS 0.9999
D1 s1 out DS
D2 s2 out DS
D3 0 s1 DS
D4 0 s2 DS
CO out 0 47u
RL out 0 24
.control
tran 10n 3m 0 10n
meas tran vout avg v(out) from=2.5m to=3m
meas tran ipk max i(LR) from=2.9m to=3m
.endc
.end
EOF
echo "f = $f kHz"
ngspice -b llc.cir 2>&1 | grep -E '^(vout|ipk) +='
donef = 120 kHz
vout = 1.351023e+01 from= 2.500000e-03 to= 3.000000e-03
ipk = 1.241484e+00 at= 2.993476e-03
f = 159.2 kHz
vout = 1.126951e+01 from= 2.500000e-03 to= 3.000000e-03
ipk = 8.045253e-01 at= 2.991838e-03
f = 200 kHz
vout = 9.954284e+00 from= 2.500000e-03 to= 3.000000e-03
ipk = 6.769465e-01 at= 2.961902e-03
SPICE gives , and . At resonance the result is the FHA's minus two diode drops of about . Away from resonance the FHA misses by a few percent, because the real current is not sinusoidal there. Designers use the FHA to choose and , then check with simulation. The tank current peaks at at and at resonance: running below resonance costs circulating current.
Guided lab
Hand calculation. For your tank values: , at full and half load, and the FHA gain at the frequencies you plan to test.
Simulation. Run the Python cell with your load range. In the deck, change RL to 12 and to 240 ohm and compare with the table.
What you would measure. Use an LLC or full-bridge evaluation board specified for an input of 24 V or less (low-voltage LLC boards exist for bus converters and education), from a current-limited supply. Sweep the frequency (or let the controller do it while you change the load) and plot against : expect the curve to pass close to minus the diode drops at , within the tolerance of and (5 to 10 % on ). Probe the switch node: with ZVS its edges are clean slopes that finish before the gate turns on. Below the gain peak (the capacitive region) you would see hard, ringing edges. Stop there: that region destroys MOSFETs at high voltage.
Hazards and safe setup. Resonant tanks build up voltages well above the input: the voltage across swings by , about here and hundreds of volts in a mains design. Keep the supply at or less and current-limited, and use rated probes. The transformer and rectifiers get hot. Off-line LLC supplies run from a PFC bus: calculation and simulation only; never open or build one.
Pitfalls
- Operating in the capacitive region (below the gain peak): ZVS is lost and the body diodes are hard-recovered.
- Trusting FHA far from resonance. It is a design-start tool; simulate the final design.
- Forgetting the dead time a ZVS bridge needs. It must be long enough for the magnetising current to swing the switch node.
- Ignoring the half bridge's capacitor-divider balance. Mismatched capacitors or unequal pulses shift the midpoint.
Practice
- A full bridge on a bus with (calculation only) runs at per half-period. Find .
- An LLC has , . Find and .
- In the worked example, the load is doubled to . Find .
Answer
- .
- ; .
- , .
Test yourself
What voltage does each switch of a half bridge or full bridge block?
How is the output of an LLC converter regulated?
- By the duty cycle
- By the switching frequency, which moves the operating point along the tank's gain curve
- By the turns ratio at run time
- By the dead time
At the series resonance , the FHA gain of an LLC is…
- zero
- one, independent of the load
- the peak gain
Why must an LLC stay on the inductive side of its gain peak?
- To reduce the output ripple
- So the tank current lags and discharges the switch node in the dead time, giving zero-voltage turn-on
- To keep the frequency low
- To avoid saturating the output capacitor