TExcelTAD
Home › Power Electronics & Motor Drives › DC-DC Component Selection: Inductor, Capacitors and Switches

DC-DC Component Selection: Inductor, Capacitors and Switches

The formulas of the last four lessons give values: 47 μH47\ \mu\text{H}, 47 μF47\ \mu\text{F}, D=0.5D = 0.5. A distributor's catalogue offers hundreds of 47 μH47\ \mu\text{H} inductors, from a 3 mm3\ \text{mm} chip that saturates at 0.3 A0.3\ \text{A} to a 20 mm20\ \text{mm} toroid good for 8 A8\ \text{A}, and "47 μF47\ \mu\text{F}" ceramic capacitors that measure 15 μF15\ \mu\text{F} at 12 V12\ \text{V}. Choosing real parts means turning each value into a list of ratings, then checking every rating against the worst case. This lesson does that for the 24 V24\ \text{V} to 12 V12\ \text{V}, 2 A2\ \text{A} buck, adds the load-step requirement that usually sets the output capacitor, and gives a checklist you can reuse for any converter.

The worst-case table

Every rating is checked at the operating point that stresses it most. For a buck:

Part Rating Worst case
Inductor LL for the ripple target; saturation current Isat>IpkI_\text{sat} > I_\text{pk} with margin; rms (thermal) current; DCR ripple and IpkI_\text{pk} at max VinV_\text{in}; current limit and start-up for IsatI_\text{sat}
Output capacitor capacitance at the DC bias, ESR, rms current, voltage ripple at max VinV_\text{in}; load step at the largest step
Input capacitor rms current IoutD(1−D)I_\text{out}\sqrt{D(1-D)}, voltage, input ripple rms at D=0.5D = 0.5 (or the DD nearest it)
Switch (MOSFET) VDS≥1.25V_{DS} \ge 1.25 to 1.5 Vin,max1.5\ V_\text{in,max} (ringing), RDS(on)R_{DS(on)} at hot junction, QgQ_g, package thermal resistance conduction loss at min VinV_\text{in} (largest DD), switching loss at max VinV_\text{in}
Diode or synchronous FET VR≥1.25 Vin,maxV_R \ge 1.25\ V_\text{in,max}, average current (1−D)Iout(1-D)I_\text{out}, forward drop or RDS(on)R_{DS(on)} at max VinV_\text{in} (largest 1−D1-D)

The inductor

Three numbers matter beyond the inductance:

  • Saturation current. Above it the core's permeability collapses and the inductance drops (by 20 or 30 % at the datasheet's IsatI_\text{sat} point, and steeply beyond); the ripple then grows, which raises the peak further. Powdered-iron and "soft-saturating" metal-composite cores degrade gradually; ferrite drops sharply. Choose IsatI_\text{sat} above the current-limit setting of the controller, not only above the normal peak, because the inductor must survive a short circuit until the limit acts.
  • rms (heating) current, usually the current that raises the part by 40 K40\ \text{K}. With small ripple it is ≈Iout\approx I_\text{out}.
  • DCR, the winding resistance: copper loss IL,rms2RDCRI_{L,\text{rms}}^2 R_\text{DCR}. Core loss from the ripple adds to it and grows with ΔIL\Delta I_L and fswf_{sw}; datasheets of 2026 parts often give an online loss calculator instead of a formula. Designing your own inductor is covered in Inductor Design.

Choose shielded inductors near sensitive circuits: an open drum radiates the switching field.

The output capacitor: ripple and load steps

The ripple requirement from The Buck Converter is usually easy to meet. The harder one is the load step: when the load jumps by ΔI\Delta I, the inductor current cannot follow instantly, so the capacitor supplies the difference until the control loop raises the duty cycle. Two estimates bracket the result:

ΔVloop≈ΔI2πfcC,ΔVslew≈L ΔI22C (VinDmax−Vout)\Delta V_\text{loop} \approx \frac{\Delta I}{2\pi f_c C}, \qquad \Delta V_\text{slew} \approx \frac{L\,\Delta I^2}{2C\,(V_\text{in}D_\text{max} - V_\text{out})}

The first assumes a loop with crossover frequency fcf_c (typically fsw/10f_{sw}/10 to fsw/5f_{sw}/5) that responds linearly; the second assumes the loop saturates at DmaxD_\text{max} immediately and the inductor current slews at its maximum rate. Take the larger, and add ΔI⋅RESR\Delta I \cdot R_\text{ESR} for the instant step. Without a loop at all, the output rings: the interactive lab below shows it.

Ceramic capacitors lose capacitance with DC bias. A class II (X5R, X7R) multilayer ceramic rated 25 V25\ \text{V} may keep only 30 to 50 % of its nominal capacitance at 12 V12\ \text{V}, and less in small packages; read the DC-bias curve in the datasheet (in 2026 the major manufacturers publish them, or an online tool, for most parts). Electrolytic and polymer capacitors keep their capacitance but have higher ESR and an rms current rating that limits their life.

Worked example: parts for the 24 V to 12 V, 2 A buck

Given: Vin=18V_\text{in} = 18 to 30 V30\ \text{V} (nominal 24 V24\ \text{V}), Vout=12 VV_\text{out} = 12\ \text{V}, Iout=2 AI_\text{out} = 2\ \text{A}, fsw=200 kHzf_{sw} = 200\ \text{kHz}, ripple ratio r≤0.35r \le 0.35, output ripple ≤1 %\le 1\ \%, load step 1 A1\ \text{A} with ΔV≤3 %\Delta V \le 3\ \% (360 mV360\ \text{mV}), loop crossover fc=20 kHzf_c = 20\ \text{kHz}, current limit 3.5 A3.5\ \text{A}.

Find: LL and its ratings, the output capacitance, the input capacitor's rms current, the MOSFET and diode voltage ratings.

Solve:

L≥Vout(1−Dmin)rIoutfsw=12⋅(1−0.4)0.35⋅2⋅200 kHz=51.4 μH⇒56 μHΔIL=12⋅0.656 μH⋅200 kHz=0.643 A,Ipk=2.32 A,Isat>3.5 ACloop≥1 A2π⋅20 kHz⋅0.36 V=22.1 μF (effective, at 12 V bias)ICin=2 A0.5⋅0.5=1.0 A at Vin=24 V,VDS, VR≥1.25⋅30=37.5 V⇒40 to 60 V parts\begin{aligned} L &\ge \frac{V_\text{out}(1 - D_\text{min})}{r I_\text{out} f_{sw}} = \frac{12 \cdot (1 - 0.4)}{0.35 \cdot 2 \cdot 200\ \text{kHz}} = 51.4\ \mu\text{H} \Rightarrow 56\ \mu\text{H} \\ \Delta I_L &= \frac{12 \cdot 0.6}{56\ \mu\text{H} \cdot 200\ \text{kHz}} = 0.643\ \text{A}, \quad I_\text{pk} = 2.32\ \text{A}, \quad I_\text{sat} > 3.5\ \text{A} \\ C_\text{loop} &\ge \frac{1\ \text{A}}{2\pi \cdot 20\ \text{kHz} \cdot 0.36\ \text{V}} = 22.1\ \mu\text{F} \ \text{(effective, at 12 V bias)} \\ I_{C_\text{in}} &= 2\ \text{A}\sqrt{0.5 \cdot 0.5} = 1.0\ \text{A at } V_\text{in} = 24\ \text{V}, \qquad V_{DS},\ V_R \ge 1.25 \cdot 30 = 37.5\ \text{V} \Rightarrow 40\ \text{to}\ 60\ \text{V parts} \end{aligned}

Check: the ripple requirement (120 mV120\ \text{mV}) is met by far: ΔVC=0.643/(8⋅22 μF⋅200 kHz)=18 mV\Delta V_C = 0.643/(8 \cdot 22\ \mu\text{F} \cdot 200\ \text{kHz}) = 18\ \text{mV}. The load step sets CC, as is usual. With ceramics that keep about 45 % at 12 V12\ \text{V}, the nominal capacitance must be about 50 μF50\ \mu\text{F}: three 22 μF22\ \mu\text{F}, 25 V25\ \text{V} parts (the code below counts them), or one polymer capacitor.

python · try it yourself
import numpy as np

Vin_min, Vin_nom, Vin_max, Vout, Iout, fsw = 18.0, 24.0, 30.0, 12.0, 2.0, 200e3
r_max, dI_step, dV_step, fc, I_lim = 0.35, 1.0, 0.36, 20e3, 3.5

L_min = Vout * (1 - Vout / Vin_max) / (r_max * Iout * fsw)
print(f"L >= {L_min*1e6:.1f} uH")

# a small catalogue of shielded inductors: (name, L, Isat, Irms, DCR)
inductors = [("A 47u", 47e-6, 3.0, 2.6, 0.045), ("B 56u", 56e-6, 2.5, 2.4, 0.060),
             ("C 56u", 56e-6, 4.2, 3.4, 0.038), ("D 68u", 68e-6, 4.0, 3.1, 0.052),
             ("E 100u", 100e-6, 3.6, 2.8, 0.090)]
for name, L, Isat, Irms, dcr in inductors:
    dI = Vout * (1 - Vout / Vin_max) / (L * fsw)
    ipk = Iout + dI / 2
    irms = Iout * np.sqrt(1 + (dI / Iout)**2 / 12)
    ok = L >= L_min and Isat > I_lim and Irms > 1.2 * irms
    print(f"  {name:7s} dI = {dI:.3f} A, Ipk = {ipk:.2f} A, Isat {Isat} A, "
          f"copper {irms**2 * dcr * 1e3:5.0f} mW  -> {'OK' if ok else 'reject'}")

# output capacitance at bias, from the load step (loop) and the slew-limited estimate
L = 56e-6
C_loop = dI_step / (2 * np.pi * fc * dV_step)
C_slew = L * dI_step**2 / (2 * dV_step * (Vin_min * 0.9 - Vout))   # Dmax = 0.9 at min input
print(f"C (loop) >= {C_loop*1e6:.1f} uF, C (slew) >= {C_slew*1e6:.1f} uF at 12 V bias")
for nominal, keep in [(22e-6, 0.45), (47e-6, 0.35)]:
    n = int(np.ceil(max(C_loop, C_slew) / (nominal * keep)))
    print(f"  {nominal*1e6:.0f} uF 25 V ceramic keeping {keep:.0%} at 12 V: {n} in parallel")

# input capacitor: rms current over the input range
for Vin in (Vin_min, Vin_nom, Vin_max):
    D = Vout / Vin
    print(f"Vin = {Vin:4.1f} V: D = {D:.3f}, Cin rms = {Iout*np.sqrt(D*(1-D)):.3f} A")
L >= 51.4 uH
  A 47u   dI = 0.766 A, Ipk = 2.38 A, Isat 3.0 A, copper   182 mW  -> reject
  B 56u   dI = 0.643 A, Ipk = 2.32 A, Isat 2.5 A, copper   242 mW  -> reject
  C 56u   dI = 0.643 A, Ipk = 2.32 A, Isat 4.2 A, copper   153 mW  -> OK
  D 68u   dI = 0.529 A, Ipk = 2.26 A, Isat 4.0 A, copper   209 mW  -> OK
  E 100u  dI = 0.360 A, Ipk = 2.18 A, Isat 3.6 A, copper   361 mW  -> OK
C (loop) >= 22.1 uF, C (slew) >= 18.5 uF at 12 V bias
  22 uF 25 V ceramic keeping 45% at 12 V: 3 in parallel
  47 uF 25 V ceramic keeping 35% at 12 V: 2 in parallel
Vin = 18.0 V: D = 0.667, Cin rms = 0.943 A
Vin = 24.0 V: D = 0.500, Cin rms = 1.000 A
Vin = 30.0 V: D = 0.400, Cin rms = 0.980 A

Inductors C, D and E pass; A has too little inductance and B saturates below the current limit. Of the three, C loses the least copper power (153 mW153\ \text{mW}); E has the smallest ripple but more than twice the copper loss. The load step, not the ripple, decides the output capacitor; and the input capacitor's worst case is at 24 V24\ \text{V}, where DD is closest to 0.5.

Interactive: a load step without a control loop

An averaged model (the switch node replaced by its average, a 12 V12\ \text{V} source; see Averaged Models) with the inductor's 30 mΩ30\ \text{m}\Omega, 47 μH47\ \mu\text{H} and 47 μF47\ \mu\text{F} with 10 mΩ10\ \text{m}\Omega ESR, starting in steady state at 2 A2\ \text{A} (the IC values), and a 1 A1\ \text{A} load step at 1 ms1\ \text{ms}. With a fixed duty cycle nothing corrects the output, and the LCLC filter rings with characteristic impedance L/C=1 Ω\sqrt{L/C} = 1\ \Omega.

05100123t (ms)V0 A1.0 A2.0 A3.0 A4.0 AI (A)V(out)I(L1)at t = 3.000 msV(sw)12.0 VV(a)11.9 VV(out)11.9 VV(c)-5.81 uVI(VAV)-2.99 AI(RL)2.99 AI(L1)2.99 AI(C1)-581 uAI(RE)-581 uAI(R1)1.99 AI(I1)1.00 A

Before the step the lab reads 11.94 V11.94\ \text{V} and 1.990 A1.990\ \text{A}. The output dips to 11.06 V11.06\ \text{V} at 1.07 ms1.07\ \text{ms} (an 0.88 V0.88\ \text{V} undershoot, close to ΔIL/C=1 V\Delta I\sqrt{L/C} = 1\ \text{V} for an undamped filter), then overshoots to 12.53 V12.53\ \text{V} at 1.22 ms1.22\ \text{ms}, while the inductor current swings up to 3.70 A3.70\ \text{A}. Raise C1C_1 to 220 μF220\ \mu\text{F}: the dip shrinks to 0.43 V0.43\ \text{V}, about half, as L/C\sqrt{L/C} predicts. A closed loop with fc=20 kHzf_c = 20\ \text{kHz} would hold it near 0.36 V0.36\ \text{V} with far less capacitance (Voltage-Mode Control).

Switches and frequency

For the MOSFET, a 60 V60\ \text{V} part in 2026 with RDS(on)R_{DS(on)} of 1010 to 20 mΩ20\ \text{m}\Omega and a gate charge of 1010 to 20 nC20\ \text{nC} is typical for this power level; its losses are worked out in Power MOSFETs and Switching Losses. A Schottky diode loses VF(1−D)Iout≈0.45⋅0.5⋅2=0.45 WV_F(1-D)I_\text{out} \approx 0.45 \cdot 0.5 \cdot 2 = 0.45\ \text{W}; a synchronous MOSFET instead loses I2RDS(on)(1−D)I^2 R_{DS(on)}(1-D) plus its body diode during dead time, often under 0.1 W0.1\ \text{W} at this current.

Frequency is a trade: higher fswf_{sw} shrinks LL and CC in proportion but raises switching and gate-drive losses in proportion too. Typical 2026 choices: 300 kHz300\ \text{kHz} to 2.2 MHz2.2\ \text{MHz} for low-voltage point-of-load bucks, 100100 to 500 kHz500\ \text{kHz} for 2424 to 48 V48\ \text{V} inputs, tens of kilohertz for kilowatt IGBT stages. Automotive designs often avoid 530530 to 1710 kHz1710\ \text{kHz}, the AM broadcast band.

Guided lab: measuring an inductor's saturation

Hand calculation. For a 47 μH47\ \mu\text{H} inductor rated Isat=3 AI_\text{sat} = 3\ \text{A}, a 12 V12\ \text{V} pulse ramps the current at 12/47 μH=0.255 A/μs12/47\ \mu\text{H} = 0.255\ \text{A}/\mu\text{s}: it reaches 3 A3\ \text{A} in 11.8 μs11.8\ \mu\text{s}.

Simulation. In the netlist lab, a 12 V12\ \text{V} PULSE source into 47 μH47\ \mu\text{H} in series with 0.1 Ω0.1\ \Omega shows the linear ramp of an ideal inductor (the lab has no saturation).

What you would measure. A low-side MOSFET switches the inductor across a 12 V12\ \text{V} bench supply with a large local capacitor (1000 μF1000\ \mu\text{F}) for short pulses (55 to 20 μs20\ \mu\text{s}, one every 10 ms10\ \text{ms}), with a Schottky freewheeling diode across the inductor and a 0.05 Ω0.05\ \Omega shunt or a current probe. The current ramps linearly, then bends upwards as the core saturates: the slope doubling marks where the inductance has halved. Expect the bend within ±20 %\pm 20\ \% of the datasheet IsatI_\text{sat}; ferrite bends sharply, powdered cores gradually.

Hazards and safe setup. 12 V12\ \text{V}, current-limited supply; the pulses are short and rare so the average current is milliamperes, but the peak current from the local capacitor is many amperes: keep the loop short, use a MOSFET and diode rated well above the peak, and never omit the freewheeling diode (the inductive kick at turn-off would avalanche the MOSFET). The local capacitor holds energy after power-off: discharge it.

Pitfalls

  • Choosing an inductor by inductance and size only. IsatI_\text{sat} above the current limit, and DCR, decide whether it survives and how warm it runs.
  • Trusting the nominal value of a ceramic capacitor. Use the capacitance at the operating DC bias and temperature.
  • Sizing CoutC_\text{out} for ripple only. The load step usually needs more.
  • Forgetting the input capacitor's rms current, or placing it far from the switch: it must sit inside the high-di/dtdi/dt loop (Snubbers and Layout).

Practice

  1. With L=68 μHL = 68\ \mu\text{H} in the worked example, find ΔIL\Delta I_L and IpkI_\text{pk} at 30 V30\ \text{V}.
  2. A load step of 2 A2\ \text{A} must stay within 100 mV100\ \text{mV} with fc=50 kHzf_c = 50\ \text{kHz}. Estimate the effective capacitance needed.
  3. A 10 μF10\ \mu\text{F} ceramic keeps 40 % at its operating bias. How many are needed for 30 μF30\ \mu\text{F} effective?
Answer
  1. ΔIL=12⋅0.6/(68 μH⋅200 kHz)=0.529 A\Delta I_L = 12 \cdot 0.6/(68\ \mu\text{H} \cdot 200\ \text{kHz}) = 0.529\ \text{A}; Ipk=2.26 AI_\text{pk} = 2.26\ \text{A}.
  2. C≥2/(2π⋅50 kHz⋅0.1 V)=63.7 μFC \ge 2/(2\pi \cdot 50\ \text{kHz} \cdot 0.1\ \text{V}) = 63.7\ \mu\text{F}.
  3. Each gives 4 μF4\ \mu\text{F}, so 88 in parallel (32 μF32\ \mu\text{F}).

Test yourself

An inductor's saturation current should exceed…

  1. the average load current
  2. the normal peak current only
  3. the controller's current-limit setting, with margin
  4. the input current

A 22 µF, 25 V X5R ceramic is used on a 12 V rail. Its effective capacitance is likely…

  1. exactly 22 µF
  2. more than 22 µF
  3. much less, often 30 to 50 % of nominal
  4. zero

In most buck designs, what sets the output capacitance?

  1. the switching ripple
  2. the load-step deviation
  3. the input voltage
  4. the inductor DCR

For a buck with an 18–30 V input and 12 V output, the input capacitor's rms current is largest at…

  1. 18 V
  2. 24 V
  3. 30 V
  4. it does not depend on the input