TExcelTAD
Home › Power Electronics & Motor Drives › Forward and Push-Pull Converters

Forward and Push-Pull Converters

The flyback stores every joule it delivers in its core, and above about 100 W100\ \text{W} that core and the peak currents get uncomfortably large (The Flyback Converter). The forward converter takes another route: a real transformer that passes energy straight through while the switch conducts, followed by the familiar buck output filter. The transformer now stores almost nothing, so it can be small. The price is a new duty: the magnetising current that builds up during every on-time must be brought back to zero before the next cycle, or the core walks into saturation. The push-pull converter avoids the reset problem by driving the core alternately in both directions with two switches. It brings its own trap, flux walking.

The single-switch forward converter

+ Vin24 V Qd Np NrDr Ns D1 D2 x Lo 22 uH Co 100 uF 2.5 Ohm out Np : Ns : Nr = 2 : 1 : 2, Lm = 500 uH, 200 kHz

While QQ conducts, the dotted ends of all windings go positive. The secondary drives current through D1D_1 into the output inductor, so the node xx sees Vin/nV_\text{in}/n (n=Np/Nsn = N_p/N_s), and the output stage is a buck. While QQ is off, D2D_2 freewheels the inductor current exactly as in a buck:

Vout=D Vinn,ΔILo=(Vin/n−Vout) DLofswV_\text{out} = \frac{D\,V_\text{in}}{n}, \qquad \Delta I_{Lo} = \frac{(V_\text{in}/n - V_\text{out})\,D}{L_o f_{sw}}

Core reset. The primary is also an inductor LmL_m, and its magnetising current rises by VinDTs/LmV_\text{in} D T_s / L_m during the on-time. When QQ turns off, that current flips into the reset winding: DrD_r conducts and returns the energy to the input, which holds −VinNp/Nr-V_\text{in} N_p/N_r across the primary until the current is zero. Volt-second balance on LmL_m:

VinDTs=VinNpNrtreset≤VinNpNr(1−D)Ts⇒Dmax=11+Nr/NpV_\text{in} D T_s = V_\text{in}\frac{N_p}{N_r} t_\text{reset} \le V_\text{in}\frac{N_p}{N_r}(1 - D)T_s \quad\Rightarrow\quad D_\text{max} = \frac{1}{1 + N_r/N_p}

With the usual Nr=NpN_r = N_p, Dmax=0.5D_\text{max} = 0.5 and the switch sees VDS=Vin(1+Np/Nr)=2VinV_{DS} = V_\text{in}(1 + N_p/N_r) = 2V_\text{in}, plus a leakage spike. Other reset schemes trade the same quantities. An RCD clamp is simple and lossy. An active clamp (a small second switch and capacitor) allows D>0.5D > 0.5 and recycles the energy. The two-switch forward puts the primary between two switches and two diodes that return it to the input: each switch sees only VinV_\text{in}, and D≤0.5D \le 0.5, which makes it popular from about 200 W200\ \text{W} to 1 kW1\ \text{kW}.

The push-pull converter

Two switches drive the two halves of a centre-tapped primary on alternate half-periods. Each conducts for DTsDT_s in its half-period, with D≤0.5D \le 0.5 minus a dead time. The core flux swings from −Bpk-B_\text{pk} to +Bpk+B_\text{pk}, so the push-pull uses twice the flux swing of a forward converter's single-quadrant core. The output is full-wave rectified, so the output filter sees twice the switching frequency:

Vout=2D Vinn,VDS=2VinV_\text{out} = \frac{2 D\,V_\text{in}}{n}, \qquad V_{DS} = 2V_\text{in}

There is no reset winding: each half-period resets the other. But only if the two volt-second products are equal. A 0.1 V0.1\ \text{V} difference in switch drop or a few nanoseconds of timing mismatch leaves a net DC volt-second per period. The magnetising current then ratchets one way until the core saturates, the flux walking problem. Peak current-mode control, which ends each pulse at the same current, cures it (Peak Current-Mode Control). So does a small DC blocking capacitor in a half-bridge (Half- and Full-Bridge Converters). Push-pull suits low input voltages (12 to 48 V battery systems), where 2Vin2V_\text{in} on the switches does no harm.

Worked example

Given: a forward converter, Vin=24 VV_\text{in} = 24\ \text{V}, Vout=5 VV_\text{out} = 5\ \text{V} at 2 A2\ \text{A}, Np:Ns:Nr=2:1:2N_p : N_s : N_r = 2 : 1 : 2, Lm=500 μHL_m = 500\ \mu\text{H}, Lo=22 μHL_o = 22\ \mu\text{H}, fsw=200 kHzf_{sw} = 200\ \text{kHz}; ideal parts.

Find: DD, the magnetising peak current, the reset margin, the switch voltage and the output-inductor ripple. Then the duty cycle of a push-pull with the same turns ratio.

Solve:

D=nVoutVin=2⋅5 V24 V=0.4167,Im,pk=24 V⋅0.4167⋅5 μs500 μH=0.100 Atreset=DTs=2.08 μs,D+Dreset=0.833<1,VDS=2⋅24 V=48 VΔILo=(12−5) V⋅0.416722 μH⋅200 kHz=0.663 A,Dpush-pull=nVout2Vin=0.208\begin{aligned} D &= \frac{nV_\text{out}}{V_\text{in}} = \frac{2 \cdot 5\ \text{V}}{24\ \text{V}} = 0.4167, \qquad I_{m,pk} = \frac{24\ \text{V} \cdot 0.4167 \cdot 5\ \mu\text{s}}{500\ \mu\text{H}} = 0.100\ \text{A} \\ t_\text{reset} &= D T_s = 2.08\ \mu\text{s}, \qquad D + D_\text{reset} = 0.833 < 1, \qquad V_{DS} = 2 \cdot 24\ \text{V} = 48\ \text{V} \\ \Delta I_{Lo} &= \frac{(12 - 5)\ \text{V} \cdot 0.4167}{22\ \mu\text{H} \cdot 200\ \text{kHz}} = 0.663\ \text{A}, \qquad D_\text{push-pull} = \frac{nV_\text{out}}{2V_\text{in}} = 0.208 \end{aligned}

Check: the magnetising current is 10 % of the reflected load current (2 A/n=1 A2\ \text{A}/n = 1\ \text{A}), a sensible size. The reset winding needs a duty cycle below 0.5 at the lowest input voltage, because DD rises as VinV_\text{in} falls.

python · try it yourself
Vin, Vout, Iout, n, Lm, Lo, fsw = 24.0, 5.0, 2.0, 2.0, 500e-6, 22e-6, 200e3
Ts = 1 / fsw
for V in (18.0, 24.0, 30.0):                         # input range of a 24 V bus
    D = n * Vout / V
    Im = V * D * Ts / Lm
    dIL = (V / n - Vout) * D * Ts / Lo
    ok = "resets" if 2 * D < 1 else "DOES NOT RESET"
    print(f"Vin = {V:4.1f} V: D = {D:.4f}, Im_pk = {Im*1e3:5.1f} mA, dI_Lo = {dIL:.3f} A, "
          f"V_DS = {2*V:.0f} V, core {ok}")

# what happens if D exceeds 0.5 with a 1:1 reset winding: the magnetising current ratchets up
D = 0.55
step = Vin * (2 * D - 1) * Ts / Lm                   # net rise per period (reset is only (1-D)Ts long)
print(f"D = {D}: magnetising current grows by {step*1e3:.1f} mA per cycle, "
      f"{step*fsw*1e-3:.1f} A per ms until the core saturates")

# push-pull flux walking: switch A drops 0.1 V more than switch B
dV = 0.1
Dpp = n * Vout / (2 * Vin)
walk = dV * Dpp * Ts / Lm                            # net volt-seconds per period / Lm
print(f"push-pull D = {Dpp:.4f}; 0.1 V mismatch walks Im by {walk*1e6:.2f} uA per cycle "
      f"= {walk*fsw:.1f} mA per ms")
Vin = 18.0 V: D = 0.5556, Im_pk = 100.0 mA, dI_Lo = 0.505 A, V_DS = 36 V, core DOES NOT RESET
Vin = 24.0 V: D = 0.4167, Im_pk = 100.0 mA, dI_Lo = 0.663 A, V_DS = 48 V, core resets
Vin = 30.0 V: D = 0.3333, Im_pk = 100.0 mA, dI_Lo = 0.758 A, V_DS = 60 V, core resets
D = 0.55: magnetising current grows by 24.0 mA per cycle, 4.8 A per ms until the core saturates
push-pull D = 0.2083; 0.1 V mismatch walks Im by 208.33 uA per cycle = 41.7 mA per ms

At the bottom of a typical 18 to 30 V range the design fails: D=0.556D = 0.556 leaves too little time to reset. A turns ratio of n=1.6n = 1.6 instead of 2 gives D=0.444D = 0.444 at 18 V18\ \text{V}, at the cost of more secondary voltage stress. Past the limit the magnetising current climbs by 24 mA24\ \text{mA} every cycle, enough to saturate a core within a fraction of a millisecond. The push-pull's walk is slower, about 42 mA42\ \text{mA} per millisecond for a 0.1 V0.1\ \text{V} mismatch, and it stops only where the offset current's extra drop in the switch and winding resistance cancels the mismatch: with about 0.1 Ω0.1\ \Omega in the path that takes an offset near 1 A1\ \text{A}, ten times the magnetising peak, so in practice the core saturates first.

Cross-check in ngspice: a forward converter with a reset winding

Three coupled windings (500500, 125125 and 500 μH500\ \mu\text{H}, so 2:1:22 : 1 : 2) with coupling 0.9990.999, a 50 mΩ50\ \text{m}\Omega switch and Schottky diodes. An RC snubber (1 nF1\ \text{nF}, 22 Ω22\ \Omega) on the drain tames the leakage ringing; without it the leakage current has nowhere to go and the simulated drain rises to tens of kilovolts. The gate is on for 2.3 μs2.3\ \mu\text{s} of 5 μs5\ \mu\text{s} (D=0.46D = 0.46) to make up for the diode drops.

bash · try it yourself
cat > forward.cir <<'EOF'
* Forward 24 V -> 5 V / 2 A, Np:Ns:Nr = 2:1:2, Lm = 500u, reset winding, 200 kHz
.model SW SW(Ron=0.05 Roff=1meg Vt=2.5 Vh=0)
.model DS D(Is=2u N=1.05 Rs=0.02 Cjo=200p)
VIN vin 0 24
VG g 0 PULSE(0 5 0 10n 10n 2.3u 5u)
LP vin d 500u
LS s 0 125u
LR 0 r 500u
K1 LP LS 0.999
K2 LP LR 0.999
K3 LS LR 0.998
S1 d 0 g 0 SW
CSN d sn 1n
RSN sn 0 22
DR r vin DS
D1 s x DS
D2 0 x DS
LO x out 22u
CO out 0 100u
RL out 0 2.5
.control
tran 10n 3m 0 10n
meas tran vout avg v(out) from=2.5m to=3m
meas tran vdmax max v(d) from=2.9m to=3m
meas tran ilpp pp i(LO) from=2.99m to=3m
let pin = -v(vin)*i(VIN)
meas tran pin_avg avg pin from=2.5m to=3m
let eff = 100*vout*vout/2.5/pin_avg
print eff
.endc
.end
EOF
ngspice -b forward.cir 2>&1 | grep -E '^(vout|vdmax|ilpp|pin_avg|eff) +='
vout                =  5.013944e+00 from=  2.500000e-03 to=  3.000000e-03
vdmax               =  4.973547e+01 at=  2.972510e-03
ilpp                =  6.713793e-01 from=  2.990000e-03 to=  3.000000e-03
pin_avg             =  1.113208e+01 from=  2.500000e-03 to=  3.000000e-03
eff = 9.033221e+01

The output is 5.01 V5.01\ \text{V}, the inductor ripple 0.671 A0.671\ \text{A} (the ideal 0.663 A0.663\ \text{A} at a slightly larger DD), and the efficiency 90.3 %. The drain peaks at 49.7 V49.7\ \text{V}: the 2Vin=48 V2V_\text{in} = 48\ \text{V} reset plateau plus a small leakage spike.

Guided lab: a forward or push-pull evaluation board

Hand calculation. For the board's turns ratio, fswf_{sw} and your input voltage, compute DD, VDS=2VinV_{DS} = 2V_\text{in} (single-switch forward and push-pull) and ΔILo\Delta I_{Lo}.

Simulation. Change the input in the Python cell to the board's minimum and maximum and check the reset margin. In the deck, raise the gate pulse to 2.7 μs2.7\ \mu\text{s} (D=0.54D = 0.54) and watch the drain waveform change.

What you would measure. Use an evaluation board rated for 24 V or less on its input (12 V push-pull modules for isolated gate-driver supplies are common), from a current-limited bench supply. With a short ground spring on each drain, the forward converter's drain shows three levels: near 0 while on, a plateau at about 2Vin2V_\text{in} during the reset, then a drop to VinV_\text{in} once the magnetising current is zero, with ringing at each edge. Each push-pull drain sits at 2Vin2V_\text{in} while the other switch conducts. Expect drain plateaus within 5 % of the calculation and spikes 20 to 50 % higher.

Hazards and safe setup. Drain voltages are at least twice the input. Leakage spikes go higher, so use a supply of no more than 24 V24\ \text{V}, current-limited, and probes rated for the drain voltage. The transformer and diodes get hot. Off-line forward converters (server and industrial supplies) run from about 400 V400\ \text{V} after a PFC stage: calculation and simulation only.

Pitfalls

  • Designing the reset at nominal input. DD is largest at minimum input, where the reset margin is smallest.
  • Ignoring flux walking in a voltage-mode push-pull. Use current-mode control or check the magnetising current at start-up.
  • Forgetting the dead time in a push-pull: both switches on at once short the centre-tapped primary.
  • Treating the forward transformer as an inductor. It needs no air gap. A gap only raises the magnetising current (High-Frequency Transformer Design).

Practice

  1. A forward converter with Nr/Np=0.5N_r/N_p = 0.5: what is DmaxD_\text{max}, and what voltage does the switch see at Vin=48 VV_\text{in} = 48\ \text{V}?
  2. A push-pull from 12 V12\ \text{V} with n=0.5n = 0.5 (Ns=2NpN_s = 2N_p) must make 15 V15\ \text{V}. Find DD.
  3. Why can a two-switch forward use 600 V600\ \text{V} switches on a 400 V400\ \text{V} bus when a single-switch forward cannot?
Answer
  1. Dmax=1/(1+0.5)=0.667D_\text{max} = 1/(1 + 0.5) = 0.667; VDS=48(1+2)=144 VV_{DS} = 48(1 + 2) = 144\ \text{V}.
  2. D=nVout/(2Vin)=0.5⋅15/24=0.3125D = nV_\text{out}/(2V_\text{in}) = 0.5 \cdot 15/24 = 0.3125.
  3. Its diodes clamp each switch to the input rail, so each sees 400 V400\ \text{V}. A single-switch forward with a 1:11{:}1 reset winding sees 800 V800\ \text{V} plus the spike.

Test yourself

Why must a forward converter's core be reset every cycle?

  1. To charge the output capacitor
  2. Because the magnetising current grows by VinDTs/LmV_\text{in} D T_s/L_m each on-time and would ratchet up into saturation if not returned to zero
  3. To keep the diodes cool
  4. To reverse the output polarity

A single-switch forward converter with a 1:1 reset winding runs from 36 V. The switch must block at least…

  1. 36 V
  2. 54 V
  3. 72 V plus the leakage spike
  4. 18 V

In a push-pull converter switching at 100 kHz (each switch once per period), the output inductor sees a ripple frequency of…

  1. 50 kHz
  2. 100 kHz
  3. 200 kHz
  4. 400 kHz

What causes flux walking in a push-pull converter?

  1. Too much output capacitance
  2. Unequal volt-seconds on the two half-periods (switch drops, timing), which leave a net DC magnetising component
  3. A reset winding
  4. Synchronous rectifiers