Forward and Push-Pull Converters
The flyback stores every joule it delivers in its core, and above about that core and the peak currents get uncomfortably large (The Flyback Converter). The forward converter takes another route: a real transformer that passes energy straight through while the switch conducts, followed by the familiar buck output filter. The transformer now stores almost nothing, so it can be small. The price is a new duty: the magnetising current that builds up during every on-time must be brought back to zero before the next cycle, or the core walks into saturation. The push-pull converter avoids the reset problem by driving the core alternately in both directions with two switches. It brings its own trap, flux walking.
The single-switch forward converter
While conducts, the dotted ends of all windings go positive. The secondary drives current through into the output inductor, so the node sees (), and the output stage is a buck. While is off, freewheels the inductor current exactly as in a buck:
Core reset. The primary is also an inductor , and its magnetising current rises by during the on-time. When turns off, that current flips into the reset winding: conducts and returns the energy to the input, which holds across the primary until the current is zero. Volt-second balance on :
With the usual , and the switch sees , plus a leakage spike. Other reset schemes trade the same quantities. An RCD clamp is simple and lossy. An active clamp (a small second switch and capacitor) allows and recycles the energy. The two-switch forward puts the primary between two switches and two diodes that return it to the input: each switch sees only , and , which makes it popular from about to .
The push-pull converter
Two switches drive the two halves of a centre-tapped primary on alternate half-periods. Each conducts for in its half-period, with minus a dead time. The core flux swings from to , so the push-pull uses twice the flux swing of a forward converter's single-quadrant core. The output is full-wave rectified, so the output filter sees twice the switching frequency:
There is no reset winding: each half-period resets the other. But only if the two volt-second products are equal. A difference in switch drop or a few nanoseconds of timing mismatch leaves a net DC volt-second per period. The magnetising current then ratchets one way until the core saturates, the flux walking problem. Peak current-mode control, which ends each pulse at the same current, cures it (Peak Current-Mode Control). So does a small DC blocking capacitor in a half-bridge (Half- and Full-Bridge Converters). Push-pull suits low input voltages (12 to 48 V battery systems), where on the switches does no harm.
Worked example
Given: a forward converter, , at , , , , ; ideal parts.
Find: , the magnetising peak current, the reset margin, the switch voltage and the output-inductor ripple. Then the duty cycle of a push-pull with the same turns ratio.
Solve:
Check: the magnetising current is 10 % of the reflected load current (), a sensible size. The reset winding needs a duty cycle below 0.5 at the lowest input voltage, because rises as falls.
Vin, Vout, Iout, n, Lm, Lo, fsw = 24.0, 5.0, 2.0, 2.0, 500e-6, 22e-6, 200e3
Ts = 1 / fsw
for V in (18.0, 24.0, 30.0): # input range of a 24 V bus
D = n * Vout / V
Im = V * D * Ts / Lm
dIL = (V / n - Vout) * D * Ts / Lo
ok = "resets" if 2 * D < 1 else "DOES NOT RESET"
print(f"Vin = {V:4.1f} V: D = {D:.4f}, Im_pk = {Im*1e3:5.1f} mA, dI_Lo = {dIL:.3f} A, "
f"V_DS = {2*V:.0f} V, core {ok}")
# what happens if D exceeds 0.5 with a 1:1 reset winding: the magnetising current ratchets up
D = 0.55
step = Vin * (2 * D - 1) * Ts / Lm # net rise per period (reset is only (1-D)Ts long)
print(f"D = {D}: magnetising current grows by {step*1e3:.1f} mA per cycle, "
f"{step*fsw*1e-3:.1f} A per ms until the core saturates")
# push-pull flux walking: switch A drops 0.1 V more than switch B
dV = 0.1
Dpp = n * Vout / (2 * Vin)
walk = dV * Dpp * Ts / Lm # net volt-seconds per period / Lm
print(f"push-pull D = {Dpp:.4f}; 0.1 V mismatch walks Im by {walk*1e6:.2f} uA per cycle "
f"= {walk*fsw:.1f} mA per ms")Vin = 18.0 V: D = 0.5556, Im_pk = 100.0 mA, dI_Lo = 0.505 A, V_DS = 36 V, core DOES NOT RESET
Vin = 24.0 V: D = 0.4167, Im_pk = 100.0 mA, dI_Lo = 0.663 A, V_DS = 48 V, core resets
Vin = 30.0 V: D = 0.3333, Im_pk = 100.0 mA, dI_Lo = 0.758 A, V_DS = 60 V, core resets
D = 0.55: magnetising current grows by 24.0 mA per cycle, 4.8 A per ms until the core saturates
push-pull D = 0.2083; 0.1 V mismatch walks Im by 208.33 uA per cycle = 41.7 mA per ms
At the bottom of a typical 18 to 30 V range the design fails: leaves too little time to reset. A turns ratio of instead of 2 gives at , at the cost of more secondary voltage stress. Past the limit the magnetising current climbs by every cycle, enough to saturate a core within a fraction of a millisecond. The push-pull's walk is slower, about per millisecond for a mismatch, and it stops only where the offset current's extra drop in the switch and winding resistance cancels the mismatch: with about in the path that takes an offset near , ten times the magnetising peak, so in practice the core saturates first.
Cross-check in ngspice: a forward converter with a reset winding
Three coupled windings (, and , so ) with coupling , a switch and Schottky diodes. An RC snubber (, ) on the drain tames the leakage ringing; without it the leakage current has nowhere to go and the simulated drain rises to tens of kilovolts. The gate is on for of () to make up for the diode drops.
cat > forward.cir <<'EOF'
* Forward 24 V -> 5 V / 2 A, Np:Ns:Nr = 2:1:2, Lm = 500u, reset winding, 200 kHz
.model SW SW(Ron=0.05 Roff=1meg Vt=2.5 Vh=0)
.model DS D(Is=2u N=1.05 Rs=0.02 Cjo=200p)
VIN vin 0 24
VG g 0 PULSE(0 5 0 10n 10n 2.3u 5u)
LP vin d 500u
LS s 0 125u
LR 0 r 500u
K1 LP LS 0.999
K2 LP LR 0.999
K3 LS LR 0.998
S1 d 0 g 0 SW
CSN d sn 1n
RSN sn 0 22
DR r vin DS
D1 s x DS
D2 0 x DS
LO x out 22u
CO out 0 100u
RL out 0 2.5
.control
tran 10n 3m 0 10n
meas tran vout avg v(out) from=2.5m to=3m
meas tran vdmax max v(d) from=2.9m to=3m
meas tran ilpp pp i(LO) from=2.99m to=3m
let pin = -v(vin)*i(VIN)
meas tran pin_avg avg pin from=2.5m to=3m
let eff = 100*vout*vout/2.5/pin_avg
print eff
.endc
.end
EOF
ngspice -b forward.cir 2>&1 | grep -E '^(vout|vdmax|ilpp|pin_avg|eff) +='vout = 5.013944e+00 from= 2.500000e-03 to= 3.000000e-03
vdmax = 4.973547e+01 at= 2.972510e-03
ilpp = 6.713793e-01 from= 2.990000e-03 to= 3.000000e-03
pin_avg = 1.113208e+01 from= 2.500000e-03 to= 3.000000e-03
eff = 9.033221e+01
The output is , the inductor ripple (the ideal at a slightly larger ), and the efficiency 90.3 %. The drain peaks at : the reset plateau plus a small leakage spike.
Guided lab: a forward or push-pull evaluation board
Hand calculation. For the board's turns ratio, and your input voltage, compute , (single-switch forward and push-pull) and .
Simulation. Change the input in the Python cell to the board's minimum and maximum and check the reset margin. In the deck, raise the gate pulse to () and watch the drain waveform change.
What you would measure. Use an evaluation board rated for 24 V or less on its input (12 V push-pull modules for isolated gate-driver supplies are common), from a current-limited bench supply. With a short ground spring on each drain, the forward converter's drain shows three levels: near 0 while on, a plateau at about during the reset, then a drop to once the magnetising current is zero, with ringing at each edge. Each push-pull drain sits at while the other switch conducts. Expect drain plateaus within 5 % of the calculation and spikes 20 to 50 % higher.
Hazards and safe setup. Drain voltages are at least twice the input. Leakage spikes go higher, so use a supply of no more than , current-limited, and probes rated for the drain voltage. The transformer and diodes get hot. Off-line forward converters (server and industrial supplies) run from about after a PFC stage: calculation and simulation only.
Pitfalls
- Designing the reset at nominal input. is largest at minimum input, where the reset margin is smallest.
- Ignoring flux walking in a voltage-mode push-pull. Use current-mode control or check the magnetising current at start-up.
- Forgetting the dead time in a push-pull: both switches on at once short the centre-tapped primary.
- Treating the forward transformer as an inductor. It needs no air gap. A gap only raises the magnetising current (High-Frequency Transformer Design).
Practice
- A forward converter with : what is , and what voltage does the switch see at ?
- A push-pull from with () must make . Find .
- Why can a two-switch forward use switches on a bus when a single-switch forward cannot?
Answer
- ; .
- .
- Its diodes clamp each switch to the input rail, so each sees . A single-switch forward with a reset winding sees plus the spike.
Test yourself
Why must a forward converter's core be reset every cycle?
- To charge the output capacitor
- Because the magnetising current grows by each on-time and would ratchet up into saturation if not returned to zero
- To keep the diodes cool
- To reverse the output polarity
A single-switch forward converter with a 1:1 reset winding runs from 36 V. The switch must block at least…
- 36 V
- 54 V
- 72 V plus the leakage spike
- 18 V
In a push-pull converter switching at 100 kHz (each switch once per period), the output inductor sees a ripple frequency of…
- 50 kHz
- 100 kHz
- 200 kHz
- 400 kHz
What causes flux walking in a push-pull converter?
- Too much output capacitance
- Unequal volt-seconds on the two half-periods (switch drops, timing), which leave a net DC magnetising component
- A reset winding