Discontinuous Conduction Mode
Take the to buck of The Buck Converter, keep the duty cycle at , and reduce the load from to . An engineer who trusts expects ; the bench shows almost . Nothing is broken: the inductor current has hit zero during each period, the diode has stopped conducting, and the converter has entered discontinuous conduction mode (DCM). Its gain now depends on the load, its control dynamics change, and the switch node rings. This lesson finds the boundary, derives the DCM gain, and shows why some converters are designed to run in DCM on purpose.
The third interval
In CCM the inductor current is a triangle of fixed height (it does not depend on the load) riding on the average . When the load falls below half the ripple, the bottom of the triangle would go negative. The diode cannot conduct backwards, so the current stops at zero and stays there: a third interval in which neither switch conducts. (A synchronous buck with a MOSFET instead of the diode can conduct backwards and stays in CCM at any load, at the cost of circulating current; many controllers deliberately turn the low-side switch off at zero current to imitate a diode, a "diode emulation" light-load mode.)
The boundary
The converter sits at the boundary when . For the buck, , so with :
DCM above (lighter load). A dimensionless form is common: , with CCM while , where for the buck and for the boost.
The DCM gain
In DCM the inductor current starts each period at zero, so the balance laws need one more unknown, . Volt-second balance on (buck):
The peak current is , and charge balance says the average inductor current (the area of the triangle over ) equals the load current:
Eliminating and gives a quadratic in whose positive root is
Both now depend on , i.e. on the load. As , : the buck's output rises to and the boost's grows without limit. That is the same story as the unloaded boost in The Boost Converter: with no load the energy delivered each cycle has nowhere to go. A closed loop fixes it by reducing (eventually below the minimum on-time, which is why controllers skip pulses at very light load).
Worked example: the buck at light load
Given: , , , , .
Find: the boundary resistance, the mode, , and .
Solve:
Check: , so a third interval of exists, as DCM requires. The average inductor current equals . The lab reads the same: DCM, where "CCM formula would give ", , a peak of and . Lower slowly to and the lab switches back to CCM at exactly .
Gain against load
import numpy as np
Vin, L, fsw, D = 24.0, 47e-6, 200e3, 0.5
Ts = 1 / fsw
def buck(R):
K = 2 * L / (R * Ts)
if K > 1 - D: # CCM
return D * Vin, "CCM"
return Vin * 2 / (1 + np.sqrt(1 + 4 * K / D**2)), "DCM"
def boost(R, Vin=12.0):
K = 2 * L / (R * Ts)
if K > D * (1 - D)**2:
return Vin / (1 - D), "CCM"
return Vin * (1 + np.sqrt(1 + 4 * D**2 / K)) / 2, "DCM"
print(" R buck Vout boost (12 V in) Vout")
for R in (6, 20, 37, 38, 50, 100, 200, 1000, 10000):
vb, mb = buck(R)
vo, mo = boost(R)
print(f"{R:7.1f} {vb:6.2f} V {mb} {vo:7.2f} V {mo}")
# the duty cycle a controller must set for 12 V out at each load (buck, DCM inverse)
print("buck duty cycle for 12 V out:")
for R in (6, 50, 200, 1000):
K = 2 * L / (R * Ts)
M = 0.5
Dccm = M
Ddcm = np.sqrt(K * M**2 / (1 - M)) # from M = 2/(1 + sqrt(1 + 4K/D^2))
Dreq = Dccm if K > 1 - Dccm else Ddcm
print(f" R = {R:5d} ohm: D = {Dreq:.3f}") R buck Vout boost (12 V in) Vout
6.0 12.00 V CCM 24.00 V CCM
20.0 12.00 V CCM 24.00 V CCM
37.0 12.00 V CCM 24.00 V CCM
38.0 12.04 V DCM 24.00 V CCM
50.0 13.16 V DCM 24.00 V CCM
100.0 15.99 V DCM 24.00 V CCM
200.0 18.59 V DCM 26.47 V DCM
1000.0 22.42 V DCM 50.17 V DCM
10000.0 23.82 V DCM 144.51 V DCM
buck duty cycle for 12 V out:
R = 6 ohm: D = 0.500
R = 50 ohm: D = 0.434
R = 200 ohm: D = 0.217
R = 1000 ohm: D = 0.097
Two consequences. The gain changes with load in DCM, so the controller must cut the duty cycle as the load falls (to at in this example); at very light load the required on-time becomes shorter than the controller's minimum on-time, and it starts skipping pulses. And in the boost the open-loop output climbs quickly as the load disappears: at and at from a input, far beyond the bench limit of this course.
The idle interval in ngspice: ringing
When both switches are off and the inductor current is zero, the switch node is left floating, connected only to the inductor and to the switch's and diode's capacitance. Charged to when the diode stops, it rings around at . The deck models the node capacitance as a capacitor ( with ) and uses a smaller output capacitor so the output settles within .
cat > dcm.cir <<'EOF'
* Buck 24 V, D = 0.5, 200 kHz, light load 100 ohm: DCM
.model SW1 SW(Ron=0.05 Roff=1meg Vt=2.5 Vh=0)
.model DSCH D(Is=5u N=1.1 Rs=0.03 BV=60 IBV=10u)
VIN vin 0 24
VG g 0 PULSE(0 5 0 10n 10n 2.5u 5u)
S1 vin sw g 0 SW1
D1 0 sw DSCH
CSW sw 0 200p
L1 sw a 47u
RL1 a out 30m
C1 out 0 10u
RLOAD out 0 100
.control
tran 10n 10m 0 10n
meas tran vout avg v(out) from=9.9m to=10m
meas tran ilpk max i(L1) from=9.995m to=10m
meas tran tfall when i(L1)=0 fall=1 from=9.995m to=10m
meas tran vswmax max v(sw) from=9.9975m to=9.99995m
meas tran vswmin min v(sw) from=9.9975m to=9.99995m
.endc
.end
EOF
ngspice -b dcm.cir 2>&1 | grep -E '^(vout|ilpk|tfall|vswmax|vswmin) +='vout = 1.586100e+01 from= 9.900000e-03 to= 1.000000e-02
ilpk = 4.266670e-01 at= 9.997518e-03
tfall = 9.998762e-03
vswmax = 3.186118e+01 at= 9.999066e-03
vswmin = -3.503944e-01 at= 9.997529e-03
The output is (the ideal DCM value was ; the diode drop and resistances take the rest), the current peaks at and falls to zero after the switch opens at (). During the idle interval the switch node swings from to , nearly , above the input. On a real board this ringing is a few megahertz, lightly damped by the inductor's losses, and is a known EMI source; some controllers time the next turn-on to a valley of it (valley switching, used in quasi-resonant flybacks, The Flyback Converter).
When DCM is the design choice
- Smaller inductor. DCM needs far less inductance, so less copper and core.
- No diode reverse recovery. The diode's current is already zero when the switch turns on, so turn-on loss is small. This is why low-power flybacks and many PFC stages below about run in DCM or at the boundary (Power-Factor Correction).
- Simpler control. The inductor current no longer carries state from one period to the next, so the power stage behaves like a first-order system (the double pole of CCM splits into one low-frequency pole and one far above), which is easier to compensate (Averaged Models).
The price is higher peak and rms currents for the same power (more conduction loss, more ripple) and the ringing. Above a few hundred watts, CCM wins.
Guided lab: watching a buck enter DCM
Hand calculation. For a non-synchronous buck evaluation board, or one with a forced-PWM option turned off, compute from its , and nominal .
Simulation. Sweep in the lab around and note where the trace changes shape.
What you would measure. Supply to from a current-limited bench supply, with a decade of load resistors ( to , each rated for with margin: in at , so a part on a heatsink). With a current probe on the inductor, the triangle's bottom touches zero at about (within the inductance tolerance), and below that the flat zero segment appears and grows. On the switch node the ringing during the idle interval is clearly visible, at the frequency set by and the node capacitance (expect to ). In closed loop the output stays regulated, but the scope shows the duty cycle shrinking with load, then pulse skipping in bursts at the lightest loads.
Hazards and safe setup. Current-limited supply at no more than ; in closed loop the output is regulated. Never open the feedback loop of a board in DCM at light load: the output rises towards the input (buck) or far above it (boost). The ringing node exceeds the supply voltage; probe it with a short ground spring.
Pitfalls
- Using CCM formulas at light load. Above the output, ripple and currents follow the DCM equations.
- Assuming a fixed plant for the controller. Crossing the CCM/DCM boundary changes the small-signal model; a loop tuned for one mode may ring in the other.
- Mistaking DCM ringing for a fault. It is the inductor with the node capacitance; damp it only if EMI needs it.
- Light-load efficiency. Fixed losses dominate at light load whatever the mode; burst or pulse-skip modes trade ripple for efficiency.
Practice
- A buck has , , . Find .
- A boost with , , runs in DCM. Find .
- Why does a synchronous buck in forced-PWM mode never enter DCM?
Answer
- .
- : DCM. , so (CCM would give ).
- Its low-side MOSFET conducts in both directions, so the inductor current simply goes negative at light load; the triangle keeps its shape and holds.
Test yourself
A non-synchronous buck enters DCM when…
- the load current exceeds the ripple
- the load current falls below half the inductor ripple
- the duty cycle exceeds 0.5
- the input voltage falls
In DCM the buck's output voltage at a fixed duty cycle…
- stays at
- rises as the load gets lighter
- falls as the load gets lighter
- becomes negative
What causes the ringing on the switch node during the idle interval of DCM?
- diode reverse recovery
- the inductor resonating with the switch and diode capacitance while both are off
- the output capacitor's ESR
- the control loop
Why do many low-power flybacks and PFC stages run in DCM or at the boundary?
- it gives lower peak currents
- the diode current is zero before the switch turns on, so reverse-recovery and turn-on losses are small, and the inductor is smaller
- it removes the need for a control loop
- it makes the output independent of the load