The Bench Power Supply and Current Limiting
A new circuit has a mistake in it: a solder bridge, a capacitor in backwards, an LED without its resistor. Powered from a battery or a USB charger, that mistake can make a part hot enough to burn you or destroy itself in a second. Powered from a laboratory bench supply with a sensible current limit, the same mistake shows up as a small number on a display and a "CC" lamp. The current limit is the most useful safety and debugging feature on the bench, and this lesson shows how it works and how to set it up before you connect anything.
Two knobs, two modes
A bench supply has a voltage setting and a current limit , and it always obeys the tighter of the two:
- Constant voltage (CV): if the load draws less than at , the output holds and the current is whatever the load takes, .
- Constant current (CC): if the load would draw more, the supply lowers its output voltage until the current equals , so .
The switch between the two happens at the crossover resistance
A load above gets CV; a load below it (including a short circuit, ) gets CC. The front panel shows which mode is active, usually with "CV" and "CC" indicators.
The dots are the operating points: the place where the supply's characteristic (solid) meets the load's line (dashed). With and , .
V_set, I_lim = 12.0, 0.5 # volts, amperes
R_c = V_set / I_lim
print(f"crossover resistance R_c = {R_c:.0f} ohm")
for R in [100, 47, 24, 10, 1, 0.1]: # load in ohms; 0.1 ohm is a short through the leads
if V_set / R <= I_lim:
mode, V, I = "CV", V_set, V_set / R
else:
mode, V, I = "CC", I_lim * R, I_lim
print(f"R = {R:6.1f} ohm {mode} V = {V:6.2f} V I = {I:.3f} A P = {V * I:5.2f} W")crossover resistance R_c = 24 ohm
R = 100.0 ohm CV V = 12.00 V I = 0.120 A P = 1.44 W
R = 47.0 ohm CV V = 12.00 V I = 0.255 A P = 3.06 W
R = 24.0 ohm CV V = 12.00 V I = 0.500 A P = 6.00 W
R = 10.0 ohm CC V = 5.00 V I = 0.500 A P = 2.50 W
R = 1.0 ohm CC V = 0.50 V I = 0.500 A P = 0.25 W
R = 0.1 ohm CC V = 0.05 V I = 0.500 A P = 0.03 W
The short circuit gets only : the current limit turned a dangerous fault into a harmless one. Without it, the same short across a lead-acid battery could deliver hundreds of amperes.
A real source has resistance; a regulated one hides it
A battery behaves like an emf behind an internal resistance , so its terminal voltage sags as current rises (see Energy, Power and Efficiency). In CV mode a bench supply's feedback loop measures its output and corrects it, so its effective output resistance is a few milliohms. In this lab (it writes voltage as ), the default is a source with driving : and the terminal voltage is . Drag to to see what regulation does: the terminal voltage stays at and the current becomes .
Remote sense
The leads between the supply and the board have resistance too. At , two leads of each drop , so a setting delivers at the board. Supplies with remote sense terminals run two extra thin wires to the load; the feedback loop regulates the voltage there and raises the output terminals to to make up the drop. The manual states how much drop it can compensate. For small currents, short thick leads are enough.
Setting up before you connect
- Output off, nothing connected.
- Set the voltage with the output open (most supplies show the setting even when off).
- Set the current limit a little above what the circuit should draw, not at the maximum. Many supplies show the limit while you hold a "set" or "limit" key; on others you turn the output on, short the output leads together for a moment and adjust the current knob. Shorting is acceptable only on a current-limited bench supply at these low settings.
- Output off, connect the circuit, red to the positive rail, black to ground. Then output on and watch the mode indicator and the current.
- If it jumps to CC at switch-on, turn the output off and look for the fault.
Other features worth knowing: over-voltage protection (OVP) trips if the output exceeds a set level, tracking links two channels for a rail, and a green terminal on the front is protective earth, not the negative output (bench supplies are usually floating, isolated from earth).
Worked example: an LED as a test load
Given: a supply set to , a red LED with a forward voltage at (example datasheet value), and E12 resistors.
Find: the series resistor, the current with the nearest E12 value, and a sensible current limit.
Solve:
Choose (the next E12 value up, so the current falls slightly below the target) and set . The supply stays in CV.
Check: if the resistor is forgotten, the LED alone would try to take far more than , so the supply drops into CC at and the display shows about . The LED survives a mistake that a battery would not forgive. The resistor dissipates , far below a rating.
Guided lab: CV and CC with a resistor and an LED
Hand calculation. As above: through and the LED; , so the resistor-plus-LED load (an effective ) is in CV.
Simulation. Run the Python table with V_set, I_lim = 5.0, 0.02 and loads of , and .
What you would measure.
- With the resistor: CV indicator on, about to (the LED's varies between about and ), read on a supply display with resolution or, better, on a multimeter in series (The Digital Multimeter).
- Lower to : the CC indicator lights, the current reads and the voltage drops to about ( plus ).
- Replace the load with a resistor and step from to with : CV up to , then CC at .
Hazards and safe setup.
- Low voltage only: set at most DC (here to ), with a current limit of tens of milliamperes. Never open the supply; its inside is at mains voltage.
- Set voltage and limit with the output off and nothing connected; connect, then switch on.
- Output capacitors discharge into the load at the moment you connect a live output; the limit does not act on that charge, so connect first, then turn the output on.
- Watch polarity: a reversed electrolytic capacitor can vent even at low voltage.
- Resistors in CC experiments get warm; check against their rating.
Pitfalls
- Setting the limit to the maximum "so it doesn't get in the way": it then protects nothing.
- Reading the supply's display as an accurate meter; its accuracy is usually coarser than a DMM's.
- Confusing the earth terminal with the negative output.
- Forgetting that a CC indicator during normal operation means the circuit is not getting the voltage you set.
Practice
- A supply is set to and . What is , and what do you read with a load?
- A board draws through leads of each. How much voltage is lost, and what does remote sense do about it?
- Why connect a circuit with the output off?
Answer
- . is below it, so CC: , .
- in the two leads. Remote sense measures at the board and raises the output terminals by .
- The output capacitors would discharge into the circuit at connection, before the current limit can act; and a live lead touching the wrong node is a fault you did not intend.
Test yourself
A supply is set to and . A load is connected. The output is
- ,
- , in CC
- ,
- : the supply shuts down
What is the crossover resistance of a supply set to and ?
What does remote sense correct?
- The supply's internal resistance
- The voltage drop in the leads between the supply and the load
- The current limit
- Mains ripple
The right order when powering a new circuit is
- connect, turn on, then set voltage and limit
- set voltage and limit with the output off, connect, turn the output on
- set the limit to maximum, connect, turn on
- turn on, short the leads, connect while on