Current, Resistance and Ohm's Law
A small 12 V pump draws 2 A through a thin cable 2 m long. At the pump the voltage is only 11.46 V and the pump runs slow. Where did the missing 0.54 V go? Into the cable: copper is a very good conductor, but not a perfect one. This lesson refreshes current, resistance and Ohm's law with the numbers an engineer uses to size wires and traces. The school lessons cover the basics: current and voltage, resistivity and Ohm's law.
Current: charge per second
Current is the rate at which charge passes a cross-section:
By convention the current arrow points the way positive charge would move, from to through the external circuit. In metals the carriers are electrons, which drift the other way. Both descriptions give the same circuit results; schematics always use the conventional direction.
The lab shows both at once and counts the charge crossing a line, :
How fast do the electrons move? With free electrons per cubic metre, a wire of cross-section carries . For copper , so in gives
less than a tenth of a millimetre per second. The lamp still lights at once because the field that pushes the electrons is set up along the whole wire at nearly the speed of light.
Resistance and resistivity
A conductor's resistance is the ratio of the voltage across it to the current through it, , in ohms (). For a uniform wire it depends on the material and the shape:
is the resistivity in , the length and the cross-section. Resistivity also changes with temperature, for metals almost linearly:
| Material | at () | (1/K) | Used for |
|---|---|---|---|
| copper (pure) | wires, PCB traces | ||
| aluminium (pure) | about | power cables, busbars | |
| nichrome | heaters, power resistors | ||
| carbon (graphite) | about | negative | carbon-film resistors |
| silicon (pure) | about | strongly negative | semiconductor devices, after doping |
Values are typical handbook figures; alloys and grades vary by a few percent. Commercial wire is rated against the International Annealed Copper Standard (IEC 60028): at with /K, about 2.6 % above the pure-copper figure this lesson uses, so real cables come out slightly worse than the examples below.
Ohm's law, and where it stops
Ohm's law says that for many conductors at constant temperature with a constant : the – graph is a straight line through the origin. Resistors, wires and traces are ohmic to a good approximation. Many parts are not: a filament lamp's resistance rises tenfold as it heats, a diode or LED conducts almost nothing until about 0.6 V (silicon) or 1.8 to 3 V (LEDs) and then very steeply. still defines a resistance at one operating point, but it is no longer one number.
Worked example: the pump cable
Given: two copper conductors, each , ; current ; . Find: the cable resistance, the voltage lost and the power wasted; the resistance when the cable is at . Solve: the current goes out and back, so the path is .
Check: a quarter of an ohm for a few metres of thin wire is the right order (thin hook-up wire is roughly per metre). Losing 0.54 V of 12 V is 4.5 %, which explains most of the slow pump; a cable cuts it to a quarter.
Sizing a cable in Python
rho, alpha = 1.68e-8, 0.0039 # copper, ohm*m and 1/K
loop_m, I, V_supply = 4.0, 2.0, 12.0
print(" A (mm^2) R (ohm) drop (V) drop (%) loss (W)")
for A_mm2 in [0.25, 0.5, 1.0, 1.5]:
R = rho * loop_m / (A_mm2 * 1e-6)
drop = I * R
print(f"{A_mm2:8.2f} {R:9.4f} {drop:10.3f} {100*drop/V_supply:9.2f} {I**2*R:10.3f}")
R20 = rho * loop_m / 0.25e-6
for T in [20, 60, 85]:
print(f"0.25 mm^2 at {T:2d} C: R = {R20*(1 + alpha*(T - 20)):.4f} ohm") A (mm^2) R (ohm) drop (V) drop (%) loss (W)
0.25 0.2688 0.538 4.48 1.075
0.50 0.1344 0.269 2.24 0.538
1.00 0.0672 0.134 1.12 0.269
1.50 0.0448 0.090 0.75 0.179
0.25 mm^2 at 20 C: R = 0.2688 ohm
0.25 mm^2 at 60 C: R = 0.3107 ohm
0.25 mm^2 at 85 C: R = 0.3369 ohm
Doubling the cross-section halves the resistance, the drop and the loss. Real cable choices also check the current rating (how hot the insulation may get), which tables in the wiring and product standards give.
Guided lab: an Ohm's-law plot
Hand calculation. A resistor at carries and dissipates , so it must be rated 1 W or more.
Simulation. The lab (it writes the voltage as ) shows the – line with points every 1.5 V. At and the ammeter reads ; the slope of the line is . Press Play to sweep the voltage.
What you would measure. On the bench use a , 0.25 W, 1 % resistor so nothing gets warm. Set the bench supply to 0, 2, 4, …, 10 V with the current limit at , and read the current on a second meter in series. Expect within about (the resistor's 1 % plus the meter's current accuracy). A least-squares slope should land between and . Swap in a small 12 V filament lamp (or an LED with a series resistor) and the points curve: not ohmic.
Hazards and safe setup: supply at most 10 V with a 20 mA limit; check the resistor's power rating before you raise the voltage; an ammeter goes in series, never directly across the supply (on its current range it is nearly a short circuit).
Pitfalls
- Forgetting the return path: a cable's loop length is twice its length.
- Using as : .
- Calling every part "a resistance": lamps, diodes and LEDs are non-linear; their depends on the operating point.
- Ignoring temperature: copper's resistance rises about 0.4 % per kelvin, so a hot motor winding or trace has noticeably more resistance than the cold figure.
Practice
- A PCB trace is thick, wide and long. Find its resistance at .
- How much charge passes a point in 10 minutes at ?
- A resistor reads at . Find .
Answer
- ; .
- .
- .
Test yourself
Doubling a wire's length and doubling its cross-section changes its resistance by a factor of…
- 4
- 2
- 1 (no change)
- 0.5
Conventional current in a wire flows…
- in the direction the electrons drift
- opposite to the electron drift, from + to - through the external circuit
- only in AC circuits
- at the speed of light
Which part is NOT ohmic?
- a metal-film resistor at constant temperature
- a short copper wire
- an LED
- a PCB trace
A copper winding has at . Roughly what is it at (/K)?