TExcelTAD
Home › EE Foundations: Units, Measurement, Safety & the Lab Notebook › ESD, Stored Energy and Battery Hazards

ESD, Stored Energy and Battery Hazards

Three hazards on a low-voltage bench have nothing to do with the supply's voltage setting. You walk across a carpet, touch a circuit board and feel nothing, yet a MOSFET on it now leaks. You switch off the bench supply, and a big capacitor still holds enough charge to weld a screwdriver tip. You drop a lithium-ion cell into a drawer with some loose wire, and an hour later the drawer is on fire. This lesson covers electrostatic discharge (ESD), energy stored in capacitors, and batteries, with numbers for each and the controls that tame them.

Electrostatic discharge

Rubbing and separating materials (shoes on carpet, a plastic bag, a sleeve on a desk) transfers charge, and a person is a capacitor of roughly 100100 to 200 pF200\ \text{pF} to the surroundings. Voltages of several kilovolts are ordinary; in dry winter air walking on synthetic carpet can reach 10 kV10\ \text{kV} or more. You feel a discharge only from about 3 kV3\ \text{kV}, so most damaging events are invisible.

The energy is tiny, but it arrives as a pulse of amperes lasting about a hundred nanoseconds, which is plenty to punch through the thin gate oxide of a MOSFET (oxide breakdown is in the tens of volts, much less for modern chips) or to melt a microscopic junction. Damage can be latent: the part still works but fails weeks later. Component sensitivity is tested with standard discharge models; the human-body model (HBM, ANSI/ESDA/JEDEC JS-001, 2024 revision as of 2026) is a 100 pF100\ \text{pF} capacitor discharged through 1.5 kΩ1.5\ \text{k}\Omega:

E=12CV2,Ipeak≈VR,τ=RC=1.5 kΩ×100 pF=150 nsE = \frac{1}{2} C V^2, \qquad I_\text{peak} \approx \frac{V}{R}, \qquad \tau = RC = 1.5\ \text{k}\Omega \times 100\ \text{pF} = 150\ \text{ns}

A datasheet that states "HBM ±2 kV\pm 2\ \text{kV}" means the pins survive that test, not that the part is immune.

Controls (the programme for workplaces is IEC 61340-5-1, edition 3 of 2024 as of 2026): a wrist strap connected to a common ground point through a built-in 1 MΩ1\ \text{M}\Omega resistor, a dissipative bench mat, ESD-safe shielding bags for storage, and handling boards by their edges. The 1 MΩ1\ \text{M}\Omega resistor drains charge in milliseconds yet limits the current if your wrist touches something live: at 24 V24\ \text{V} it allows only 24 μA24\ \mu\text{A}. Never replace it with a plain wire, and never ground yourself directly to a mains earth.

Stored energy in capacitors

A capacitor keeps its charge after the supply is switched off. Its energy is 12CV2\tfrac{1}{2}CV^2, and through a short circuit it is released in microseconds. A bleed resistor across the capacitor discharges it with time constant τ=RC\tau = RC:

v(t)=V0 e−t/RC,tsafe=RCln⁡V0Vsafev(t) = V_0\, e^{-t/RC}, \qquad t_\text{safe} = RC \ln\frac{V_0}{V_\text{safe}}

Discharge a capacitor through a resistor sized for the peak power V02/RV_0^2/R (with a lead clip, power off), check the voltage with a meter, and only then handle it. Electrolytics can also recover a small voltage after discharge (dielectric absorption), so short larger ones with a resistor while stored.

Batteries

A battery stores far more energy than any capacitor on your bench and cannot be switched off. Its short-circuit current is E/r\mathcal{E}/r (see Sources, Switches and Fuses); for a lithium-ion cell with tens of milliohms that is tens to over a hundred amperes, enough to make a thin wire glow and to heat the cell itself. Above a critical temperature, or after mechanical damage, overcharging or overdischarging, a lithium-ion cell can go into thermal runaway: it vents flammable electrolyte and burns, and the fire spreads to neighbouring cells.

Rules for this course:

  • No charging experiments with lithium cells, no home-made chargers, no deliberate shorting, piercing, heating or crushing of any cell. Use cells only inside commercial products with their own protection circuit, or in commercial battery holders.
  • Put a fuse as close to the battery terminal as possible in anything you build from a battery: it protects the wiring from the full short-circuit current.
  • Cover terminals when cells are stored or carried; never carry loose cells with coins and keys.
  • Swollen, dented, hot or leaking cells: stop using them, keep them away from flammables and hand them in at a battery collection point.
  • Keep coin cells away from children: swallowed, they cause severe internal burns within hours.

Worked example: how long until it is safe to touch?

Given: a 4700 μF4700\ \mu\text{F} reservoir capacitor charged to 24 V24\ \text{V}, with a 2.2 kΩ2.2\ \text{k}\Omega bleed resistor across it; "safe to handle" here means below 1 V1\ \text{V}. Find: the stored energy, the time constant, the waiting time and the bleed resistor's power at switch-off. Solve: E=12(4700×10−6 F)(24 V)2=1.35 JE = \tfrac{1}{2}(4700 \times 10^{-6}\ \text{F})(24\ \text{V})^2 = 1.35\ \text{J}. τ=2200 Ω×4700×10−6 F=10.3 s\tau = 2200\ \Omega \times 4700 \times 10^{-6}\ \text{F} = 10.3\ \text{s}. t=10.3 s×ln⁡(24/1)=32.9 st = 10.3\ \text{s} \times \ln(24/1) = 32.9\ \text{s}. P=(24 V)2/2200 Ω=0.262 WP = (24\ \text{V})^2/2200\ \Omega = 0.262\ \text{W}. Check: about three time constants, as expected for a factor of 24≈e3.224 \approx e^{3.2}. A 0.25 W0.25\ \text{W} resistor would be slightly overloaded for the first seconds: choose 0.5 W0.5\ \text{W}. 1.35 J1.35\ \text{J} will not stop a heart through dry skin at 24 V24\ \text{V}, but shorted by metal it makes a loud spark and pits the tool.

Intuition: a battery shorted by a thin wire

The lab's "cell" is a real source; set it as a 12 V12\ \text{V} battery with 0.1 Ω0.1\ \Omega internal resistance (the lab writes voltage as UU) and a 0.5 Ω0.5\ \Omega length of thin wire across it. The current is 12/0.6=20 A12/0.6 = 20\ \text{A}, the wire dissipates 200 W200\ \text{W} and the battery itself 40 W40\ \text{W}. Simulation only: never reproduce this on a bench. A real lead-acid battery has a lower internal resistance and would deliver far more.

+−ℰ = 12.0 Vr = 0.1 Ωreal cellVU = 10.00 VR = 0.5 ΩAI = 20.00 AI05101520R (Ω)PR (W)max 360.0 W at R = r200.0in 10.0 s: 2000 J into R, 400 J wasted in the cell

Code: three energy hazards in numbers

python · try it yourself
import math
import numpy as np
import matplotlib.pyplot as plt

# 1) Human-body model: 100 pF charged to V, discharged through 1.5 kohm.
C_HBM, R_HBM = 100e-12, 1500.0
for v in (500, 3000, 10000):
    print(f"HBM {v:>5} V: energy {0.5 * C_HBM * v**2 * 1e3:6.3f} mJ, peak {v / R_HBM:5.2f} A, "
          f"tau {R_HBM * C_HBM * 1e9:.0f} ns")

# 2) A reservoir capacitor and its bleed resistor.
C, V0, R_bleed, V_safe = 4700e-6, 24.0, 2200.0, 1.0
tau = R_bleed * C
t_safe = tau * math.log(V0 / V_safe)
print(f"4700 uF at 24 V: energy {0.5 * C * V0**2:.2f} J, tau {tau:.1f} s, "
      f"below {V_safe:.0f} V after {t_safe:.1f} s, bleed power at start {V0**2 / R_bleed:.3f} W")

# 3) Short-circuit currents I = emf / (r_internal + r_wire), r values typical, not measured.
for name, emf, r in (("AA alkaline", 1.5, 0.15), ("9 V alkaline", 9.0, 2.0),
                     ("Li-ion 18650", 3.7, 0.03), ("12 V lead-acid", 12.6, 0.01)):
    i = emf / (r + 0.02)                      # 20 mohm of wire
    print(f"{name:<15} short-circuit current about {i:6.0f} A, power in the wire {i**2 * 0.02:7.1f} W")

t = np.linspace(0, 40, 401)
plt.plot(t, V0 * np.exp(-t / tau))
plt.axhline(V_safe, ls="--", color="grey")
plt.xlabel("time after switch-off (s)"); plt.ylabel("capacitor voltage (V)")
plt.title("4700 uF discharging through 2.2 kohm")
plt.show()
HBM   500 V: energy  0.013 mJ, peak  0.33 A, tau 150 ns
HBM  3000 V: energy  0.450 mJ, peak  2.00 A, tau 150 ns
HBM 10000 V: energy  5.000 mJ, peak  6.67 A, tau 150 ns
4700 uF at 24 V: energy 1.35 J, tau 10.3 s, below 1 V after 32.9 s, bleed power at start 0.262 W
AA alkaline     short-circuit current about      9 A, power in the wire     1.6 W
9 V alkaline    short-circuit current about      4 A, power in the wire     0.4 W
Li-ion 18650    short-circuit current about     74 A, power in the wire   109.5 W
12 V lead-acid  short-circuit current about    420 A, power in the wire  3528.0 W

The internal resistances are typical orders of magnitude, not measurements; real cells vary with chemistry, size, age and temperature. The point is the ratio: the same 20 mΩ20\ \text{m}\Omega wire that warms slightly on an AA cell becomes a heater on a lithium-ion cell and an arc welder on a car battery.

Guided lab: bleeding a capacitor and measuring it

Hand calculation. For a 1000 μF1000\ \mu\text{F}, 25 V25\ \text{V} electrolytic charged to 12 V12\ \text{V} and a 10 kΩ10\ \text{k}\Omega bleed resistor: τ=10 s\tau = 10\ \text{s}; the voltage should fall to 12 e−1=4.41 V12\,e^{-1} = 4.41\ \text{V} after 10 s10\ \text{s} and below 1 V1\ \text{V} after 10ln⁡12=24.8 s10 \ln 12 = 24.8\ \text{s}.

Simulation. Change C, V0 and R_bleed in the code to these values and compare the printed time with your result.

What you would measure. Charge the capacitor from the bench supply (12.0 V12.0\ \text{V}, current limit 50 mA50\ \text{mA}, correct polarity), disconnect the supply leads, and read the voltage with the multimeter every 5 s5\ \text{s} while the bleed resistor discharges it. Expect about 7.3 V7.3\ \text{V} at 5 s5\ \text{s} and 4.4 V4.4\ \text{V} at 10 s10\ \text{s}. The meter's own 10 MΩ10\ \text{M}\Omega input barely changes τ\tau, but the electrolytic's tolerance (±20 %\pm 20\ \%) does: the measured τ\tau may lie anywhere from about 88 to 12 s12\ \text{s}. Plot ln⁡v\ln v against tt: the slope is −1/τ-1/\tau.

Hazards and safe setup

  • At most 24 V24\ \text{V} and within the capacitor's voltage rating, polarity checked; eye protection, since a reversed or over-voltaged electrolytic can vent.
  • Discharge through the resistor and verify with the meter before touching; never short a capacitor with a tool.
  • Wear the wrist strap when handling the board and ICs; take it off before leaving the bench.

Pitfalls

  • "I felt nothing, so there was no ESD": damage starts far below the 3 kV3\ \text{kV} you can feel.
  • A wrist strap without its resistor, or not connected to anything.
  • Trusting "off" on a supply: its output capacitors and your circuit's capacitors stay charged.
  • Treating a small lithium cell as harmless because its voltage is low.

Practice

  1. What energy does the HBM store at 2 kV2\ \text{kV}, and what is the peak current?
  2. A 10 mF10\ \text{mF} capacitor bank at 50 V50\ \text{V}: how much energy?
  3. Why is the fuse placed next to the battery rather than near the load?
Answer
  1. E=12(100×10−12)(2000)2=0.2 mJE = \tfrac{1}{2}(100 \times 10^{-12})(2000)^2 = 0.2\ \text{mJ}; I≈2000/1500=1.33 AI \approx 2000/1500 = 1.33\ \text{A}.
  2. E=12(0.01)(50)2=12.5 JE = \tfrac{1}{2}(0.01)(50)^2 = 12.5\ \text{J}: enough to cause burns and eye injuries through a short. (It is also above the 24 V24\ \text{V} limit of this course's bench.)
  3. A short anywhere in the wiring between battery and load is then protected too; a fuse near the load leaves that wire unprotected against the full battery current.

Test yourself

Why can ESD destroy a MOSFET even though the energy is less than a millijoule?

  1. The energy heats the whole chip
  2. Kilovolts arrive in a nanosecond-scale pulse of amperes, far above the tens of volts its thin gate oxide can withstand
  3. MOSFETs are magnetic
  4. Because ESD is AC

What is the 1 MΩ1\ \text{M}\Omega resistor in an ESD wrist strap for?

  1. It makes the strap more comfortable
  2. It drains static charge slowly enough while limiting current if the wearer touches a live conductor
  3. It measures the voltage
  4. It speeds up discharge

A 2200 μF2200\ \mu\text{F} capacitor at 20 V20\ \text{V} is bled through 4.7 kΩ4.7\ \text{k}\Omega. What is the time constant?

  1. About 1 s1\ \text{s}
  2. About 10 s10\ \text{s}
  3. About 100 s100\ \text{s}
  4. About 0.1 s0.1\ \text{s}

Which of these is allowed in this course?

  1. Charging a lithium-ion cell with a home-made charger
  2. Shorting an alkaline cell briefly to see the current
  3. Using a commercial battery holder with a fuse next to the battery
  4. Puncturing a swollen pouch cell to release gas