TExcelTAD

EE Foundations: Introduction

You have a battery pack, a resistor and a multimeter. The label says 4.5 V, the meter says 4.62 V with nothing connected and 4.41 V once the resistor is across it. Which number is "right"? Why did the voltage drop? Is a 0.2 V difference a fault, a property of the battery, or the meter? And could you have touched the wires safely?

Answering those questions well is most of what this course teaches. Electrical engineering is not a pile of formulas: it is a habit of predicting what a circuit will do, measuring what it actually does, knowing how far to trust both numbers, and writing it down so that someone else can check you. This first course of the Electrical Engineering track gives you the tools for that habit: units and notation, a physics refresher, components and schematics, electrical safety, the bench instruments, measurement uncertainty, a Python and SPICE toolkit, and the lab notebook.

The map

orientationwhat EE covers units and numbersSI, notation, dimensions physics refreshercharge to heat componentsand schematics electrical safetybody, bench, ESD the lab benchmeter, supply, scope measurement, software, documentationuncertainty, Python, SPICE, notebook, report exercises and mini project
Section You will be able to Labs and tools
Getting started say what each EE field does and how this track is organised
Units, numbers and notation write any quantity with the right unit, prefix and number of digits, and catch a wrong formula by its units Python
Physics refresher connect charge, field, potential, current, energy, magnetism and heat to circuits coulomb, field-lines, charge-flow, ohms-law, dc-power, induction, ac
Components and schematics pick a resistor value from an E-series, read a datasheet and a schematic circuit
Electrical safety explain how current harms people and set up a safe low-voltage bench
The lab bench use a multimeter, a bench supply, an oscilloscope and a function generator within their limits ngspice
Measurement, software, documentation state a result with its uncertainty, run a SPICE deck, keep a notebook, write a report error-bars, best-fit, Python, ngspice

How to study engineering

The owner's roadmap for this track suggests 10 to 15 hours a week: about half on theory and problems, a fifth on simulation and programming, and the rest on lab work and writing up. Whatever your pace, each topic goes round the same study cycle:

  1. Read the idea and its formula, then close the page and say it in your own words.
  2. Solve by hand a small problem with units on every number. Estimate the answer before you calculate it.
  3. Simulate the same circuit: Python here, SPICE from the toolchain lesson on. If simulation and hand calculation disagree, one of them is wrong, and finding out which teaches more than either.
  4. Measure (safely, at low voltage) and compare with the prediction, including the uncertainty.
  5. Write it up in the notebook: what you expected, what you got, why they differ.

This is the scientific method applied to hardware. A prediction is a hypothesis; a measurement tests it; a disagreement larger than the uncertainty means the model needs changing, not the data.

Conventions used in this track

  • Symbols. Voltage is VV (instantaneous value v(t)v(t)), current II or i(t)i(t), emf E\mathcal{E}, resistance RR, power PP. School physics courses and the physics labs write voltage as UU, as European textbooks do; it is the same quantity.
  • Units are upright and separated from the number by a space: 4.7 kΩ4.7\ \text{k}\Omega, 10 μF10\ \mu\text{F}, 25 ∘C25\,^\circ\text{C}.
  • Worked examples use the layout Given / Find / Solve / Check. The check asks whether the size and the unit make sense.
  • Safety. Every hands-on activity in this track is low voltage, isolated and current limited: batteries, a bench supply set to at most 24 V24\ \text{V} DC with a current limit, a function generator or a USB-powered board. Mains-voltage topics are taught by calculation and simulation only, and the lesson says so.

A first prediction, measurement and check

The opening puzzle, as a worked example. A battery is not an ideal source: it behaves like an ideal emf E\mathcal{E} in series with a small internal resistance rr. With a load RR the current is I=E/(R+r)I = \mathcal{E}/(R + r) and the terminal voltage drops by IrIr:

V=E−Ir=E RR+r⟹r=R(EV−1)V = \mathcal{E} - Ir = \mathcal{E}\,\frac{R}{R + r} \quad\Longrightarrow\quad r = R\left(\frac{\mathcal{E}}{V} - 1\right)

Given: open-circuit reading E=4.62 V\mathcal{E} = 4.62\ \text{V}, reading with the load V=4.41 VV = 4.41\ \text{V}, load R=10.0 ΩR = 10.0\ \Omega. Each voltage reading is uncertain by ±0.02 V\pm 0.02\ \text{V} (the meter's accuracy on this range). Find: the internal resistance rr and the current II. Solve: I=V/R=4.41 V/10.0 Ω=0.441 AI = V/R = 4.41\ \text{V} / 10.0\ \Omega = 0.441\ \text{A}. Then r=10.0 Ω×(4.62/4.41−1)=10.0 Ω×0.0476=0.476 Ωr = 10.0\ \Omega \times (4.62/4.41 - 1) = 10.0\ \Omega \times 0.0476 = 0.476\ \Omega. Check: a few tenths of an ohm is typical for three fresh AA alkaline cells in series, and Ir=0.441 A×0.476 Ω=0.21 VIr = 0.441\ \text{A} \times 0.476\ \Omega = 0.21\ \text{V} is exactly the drop we saw. But the drop is only ten times the meter's uncertainty, so rr is poorly known, as the code shows.

python · try it yourself
E, V, R = 4.62, 4.41, 10.0          # V, V, ohm
dV = 0.02                           # meter uncertainty of each reading, V

def r_internal(E, V, R):
    return R * (E / V - 1)

r = r_internal(E, V, R)
r_lo = r_internal(E - dV, V + dV, R)   # smallest r the readings allow
r_hi = r_internal(E + dV, V - dV, R)   # largest r
print(f"I = {V / R:.3f} A")
print(f"r = {r:.3f} ohm, range {r_lo:.3f} to {r_hi:.3f} ohm")
print(f"relative spread: +/-{(r_hi - r_lo) / 2 / r * 100:.0f} %")
I = 0.441 A
r = 0.476 ohm, range 0.384 to 0.569 ohm
relative spread: +/-20 %

The answer is uncertain by about 20 % in either direction, because both readings move it. Taking the extremes like this is the crude way to propagate uncertainty; the measurement uncertainty lesson does it properly. The lesson for now: a small difference of two large numbers is always poorly known.

The lab below shows the same model with round numbers the sliders allow: a 4.5 V4.5\ \text{V} emf with r=0.5 Ωr = 0.5\ \Omega driving R=10 ΩR = 10\ \Omega (the lab writes the terminal voltage as UU). It reads I=0.43 AI = 0.43\ \text{A} and U=4.29 VU = 4.29\ \text{V}. Drag RR down and watch the terminal voltage sag, the power lost inside the cell grow, and the efficiency fall.

+−ℰ = 4.5 Vr = 0.5 Ωreal cellVU = 4.29 VR = 10.0 ΩAI = 0.43 AI05101520R (Ω)PR (W)max 10.1 W at R = r1.8in 4.0 s: 7 J into R, 0 J wasted in the cell

What you would measure. With three fresh AA cells and a 10 Ω10\ \Omega, 5 W5\ \text{W} resistor you would read about 4.64.6 to 4.8 V4.8\ \text{V} open circuit and 0.1 to 0.3 V less under load. The loaded reading creeps down over a minute as the cells warm and polarise, so note the time of each reading. Hazards and safe setup: the resistor dissipates about 2 W2\ \text{W} and gets hot, so mount it in free air and don't touch it; connect it only while reading; never join the battery terminals directly (an AA pack can deliver several amperes into a short and the wires heat quickly).

Where this course leads

Next in the track come Circuit Theory, Analog Electronics and Measurements. The mathematics they need lives in the Mathematics track: Linear Algebra for circuit equations, Differential Equations for transients, Signals and Fourier for frequency analysis, and Probability for noise and uncertainty. If a physics idea here feels thin, the School Physics courses explain it from the start, for example current and voltage.

Practice

  1. A 9 V battery reads 9.30 V9.30\ \text{V} open circuit and 8.70 V8.70\ \text{V} with a 100 Ω100\ \Omega load. Find rr.
  2. Why would you measure the open-circuit voltage before connecting the load, not after?
Answer
  1. r=100 Ω×(9.30/8.70−1)=100 Ω×0.0690=6.9 Ωr = 100\ \Omega \times (9.30/8.70 - 1) = 100\ \Omega \times 0.0690 = 6.9\ \Omega, plausible for a part-used 9 V battery, which is six small cells in series and has a much higher rr than an AA cell.
  2. Drawing current warms and partly discharges the cells, so the open-circuit voltage measured afterwards is lower for a while; both readings should describe the same state of the battery. Writing down the order and the time is part of a good notebook.

Test yourself

A simulation and a hand calculation of the same circuit disagree. What is the right next step?

  1. Trust the simulation, computers don't make mistakes
  2. Trust the hand calculation, simulators are approximations
  3. Find out which one is wrong before going on
  4. Average the two

A battery reads 6.00 V6.00\ \text{V} open circuit and 5.80 V5.80\ \text{V} with a 20 Ω20\ \Omega load. What is its internal resistance?

  1. 0.20 Ω0.20\ \Omega
  2. 0.69 Ω0.69\ \Omega
  3. 1.0 Ω1.0\ \Omega
  4. 20 Ω20\ \Omega

Which of these is a hands-on activity allowed in this track?

  1. Measuring the voltage of a wall socket with a multimeter
  2. Measuring a battery pack under a resistive load
  3. Opening a phone charger to look at the transformer
  4. Charging a lithium cell from a bench supply

A measured difference between prediction and measurement is smaller than the measurement uncertainty. What can you conclude?

  1. The model is proven correct
  2. The measurement does not contradict the model
  3. The meter is broken
  4. The model is wrong