Safe Bench Practice: Low Voltage, Isolation, Earthing and Protection

How Electric Current Harms the Body showed that a few tens of milliamperes through the chest can kill and that body impedance can fall to around a kilohm. This lesson turns that into rules for your bench and explains the protective ideas behind them. Everything mains-related here is explained and calculated only; in this course you never work on mains circuits, open mains equipment or use mains-connected parts in a build.

The bench rule

Work only on circuits powered from batteries, a current-limited isolated bench supply set to at most 24 V24\ \text{V} DC, a function generator, or a USB-powered board. Set the current limit before you connect anything.

The rest of this lesson explains why each word is there.

Extra-low voltage, SELV and PELV

IEC 61140 (Protection against electric shock: common aspects for installations and equipment, edition 4, 2016) and the wiring standard IEC 60364-4-41 (edition 5, 2005, amended 2017) use voltage bands. Extra-low voltage (ELV) is at most 50 V50\ \text{V} AC rms or 120 V120\ \text{V} ripple-free DC (limits as of 2026). Two protective measures are built on it:

Measure What it means
SELV (safety extra-low voltage) ELV from a safety source (for example a safety isolating transformer to IEC 61558-2-6 or a battery), separated from mains by double or reinforced insulation (protective separation) and not connected to earth
PELV (protective extra-low voltage) the same, but the circuit is connected to protective earth at some point

ELV is a limit, not a guarantee of safety. The worked example in the previous lesson found 66 to 16 mA16\ \text{mA} from 24 V24\ \text{V} AC with sweaty hands; the installation standards set lower limits for wet locations, and even a 12 V12\ \text{V} battery can cause burns through a short circuit. The current limit of a bench supply addresses that second hazard.

Isolation. A safety isolating transformer has no conductive connection between its primary and secondary, so the secondary is not referenced to earth: touching one secondary terminal while standing on the floor drives no current through you. Touching both terminals still does, and an isolated secondary also hides faults from the residual current device on the primary side. Isolation transformers used to work on mains-powered equipment are tools for qualified technicians and are not part of this course.

Intuition: what "230 V" really is

The mains is 230 V230\ \text{V} rms at 50 Hz50\ \text{Hz} in Europe (220220 to 240 V240\ \text{V} in much of Asia, Africa and Oceania; 100100 to 127 V127\ \text{V} at 5050 or 60 Hz60\ \text{Hz} in Japan and North America, 120 V120\ \text{V} at 60 Hz60\ \text{Hz} in the USA; nominal voltages per IEC 60038, edition 7 of 2009 with amendment 1 of 2021). The lab's mains preset shows it in slow motion (the lab writes voltage as UU): the peak is U0=2302=325 VU_0 = 230\sqrt{2} = 325\ \text{V}, the period 20 ms20\ \text{ms}, and a 100 Ω100\ \Omega resistor across it would dissipate 529 W529\ \text{W}. This is a calculation to look at, never a circuit to build.

U0rotating phasoru (V)tUrms = 230 V325−325T = 20 msp = u²/R (W)average P = 529 W10580R = 100 Ωi = 0.0 Aslow motion:1 s here = 10 ms

Insulation, creepage distances and instrument ratings must survive the peak, 325 V325\ \text{V}, plus transient overvoltages far above it.

Earthing, and why the scope's ground clip is earthed

In a building, every exposed metal part of Class I equipment is connected to protective earth (PE) through the earth pin of the plug. If a live wire touches the case, a large fault current flows to earth and the fuse or circuit breaker disconnects. A mains-powered oscilloscope is Class I: its BNC shells and the ground clips of its probes are joined to PE.

bench supplyfloating output12 V, 0.1 A limit +- circuitunder test probe tip ground clip to 0 V oscilloscopeClass I, mainsBNC shell = PE PE via plug the floating supply lets the clip go on any node;a node already tied to earth elsewhere would beshorted to it through the clip

So the ground clip is always at earth potential. With a floating (isolated) bench supply or a battery that does no harm: the circuit takes the clip's potential. But if the circuit is already connected to earth somewhere else, for example through a supply whose negative output is linked to its earth terminal, clipping onto any other node shorts that node to earth through the probe lead, which burns the lead or the circuit. On mains-connected circuits the same mistake is lethal; that is one more reason they are excluded here. Never defeat a scope's earth by cutting the earth pin or using an adapter: that leaves the whole instrument case at whatever voltage the clip touches.

Fuses, circuit breakers and RCDs

Device Senses Protects against Does not protect against
fuse, miniature circuit breaker (MCB) overcurrent in the line, typically amperes to kiloamperes overloads and short circuits that would overheat wiring; faults to an earthed case shocks: body currents of tens of milliamperes are far below their trip currents
residual current device (RCD, RCCB, RCBO) the difference between line and neutral current, i.e. current leaking to earth most shocks from line to earth, earth-leakage fires a person touching line and neutral: the current returns through neutral and there is no residual

A 30 mA30\ \text{mA} RCD (rated residual current IΔn=30 mAI_{\Delta n} = 30\ \text{mA}) is required by IEC 60364-4-41 as additional protection for many socket outlets. For the general type (IEC 61008-1 and 61009-1, as of 2026) the maximum break time is 300 ms300\ \text{ms} at IΔnI_{\Delta n} and 40 ms40\ \text{ms} at 5 IΔn5\,I_{\Delta n} (for 30 mA30\ \text{mA} devices the standards also allow the 40 ms40\ \text{ms} limit to be declared at 0.25 A0.25\ \text{A} instead). Limiting the duration of a shock is what greatly reduces the risk of fibrillation; it does not stop you feeling the shock or being injured by it. Use the RCD's test button as the manufacturer recommends, typically every few months: it is the only check a non-electrician should do.

Worked example: does the RCD see it?

Given: two fault paths at 230 V230\ \text{V} (calculation only), each driving 150 mA150\ \text{mA} through a person: (a) one hand on a live conductor, feet on the earthed floor; (b) one hand on line, the other on neutral, feet insulated. A 30 mA30\ \text{mA} RCD protects the circuit. Find: the residual current the RCD sees in each case and whether it trips. Solve: (a) 150 mA150\ \text{mA} leaves on L and returns through earth, so the residual is 150 mA=5 IΔn150\ \text{mA} = 5\,I_{\Delta n}: it trips, within 40 ms40\ \text{ms} for a device rated at 5 IΔn5\,I_{\Delta n} (one declared at 0.25 A0.25\ \text{A} only has to beat its 2 IΔn2\,I_{\Delta n} limit, 150 ms150\ \text{ms}, at this current). (b) 150 mA150\ \text{mA} leaves on L and returns on N: residual 0 mA0\ \text{mA}, no trip. Check: case (b) is why an RCD is "additional" protection and why insulation, enclosures and procedures come first.

Measurement categories

Instruments and probes that may touch mains circuits are rated by IEC 61010-1 (edition 3, 2010, amended 2016) and, for meters and probes, IEC 61010-2-030 and IEC 61010-031. The measurement category tells you the transient overvoltage it survives:

Category Where Example
(no category, "O"; formerly CAT I) circuits not directly connected to mains battery circuits, this course's bench
CAT II equipment plugged into sockets appliance supply terminals
CAT III building installation distribution boards, fixed wiring
CAT IV source of the installation meter, service entry, overhead lines

A meter marked "CAT III 600 V" is rated for that category and voltage; the lowest rating among meter, leads and probes applies. Your bench work is in the uncategorised low-voltage area, but buy a meter with a proper CAT rating anyway: it tells you the maker followed the standard.

Lockout/tagout (LOTO) is the workplace procedure for isolating machinery and installations before work: switch off, lock the isolator off with a personal lock and tag, verify the absence of voltage with a tested tester, and only then work (EN 50110-1 in Europe lists five such safety rules). Apply its spirit at the bench: switch off the supply before changing a circuit.

Code: bands, residual current and a risk matrix

python · try it yourself
import math

def voltage_band(v, ac=True):
    """ELV limits of IEC 61140 / IEC 60364-4-41 (2026): 50 V AC rms, 120 V ripple-free DC."""
    limit = 50 if ac else 120
    return "ELV" if v <= limit else "above ELV"

for v, ac in ((5, False), (24, False), (48, False), (24, True), (230, True)):
    kind = "AC rms" if ac else "DC"
    peak = f", peak {v * math.sqrt(2):.0f} V" if ac else ""
    print(f"{v:>4} V {kind:<6} -> {voltage_band(v, ac)}{peak}")

# A residual current device compares the current out on L with the current back on N.
def rcd_sees(i_line_to_earth, i_line_to_neutral):
    return i_line_to_earth            # current returning through N cancels; only the earth leak is "residual"
for path, ie, i_n in (("hand to earth", 0.150, 0.0), ("hand L to hand N", 0.0, 0.150)):
    res = rcd_sees(ie, i_n)
    print(f"{path:<17} body current 150 mA, residual {res * 1000:3.0f} mA -> {'trips' if res >= 0.030 else 'does NOT trip'}")

# Risk matrix: likelihood and severity from 1 (low) to 3 (high), before and after controls.
tasks = [
    ("hot resistor or iron burns skin", 3, 1, "current limit, let parts cool, iron in stand", 2, 1),
    ("battery short melts a wire",      2, 2, "fuse at the battery, cover terminals",         1, 2),
    ("solder splash in the eye",        2, 2, "safety glasses",                               1, 1),
    ("scope ground clip on mains part", 1, 3, "no mains circuits on the bench at all",         0, 3),
]
print(f"{'hazard':<34}{'before':>7}{'after':>6}  control")
for text, l0, s0, control, l1, s1 in tasks:
    print(f"{text:<34}{l0 * s0:>7}{l1 * s1:>6}  {control}")
   5 V DC     -> ELV
  24 V DC     -> ELV
  48 V DC     -> ELV
  24 V AC rms -> ELV, peak 34 V
 230 V AC rms -> above ELV, peak 325 V
hand to earth     body current 150 mA, residual 150 mA -> trips
hand L to hand N  body current 150 mA, residual   0 mA -> does NOT trip
hazard                             before after  control
hot resistor or iron burns skin         3     2  current limit, let parts cool, iron in stand
battery short melts a wire              4     2  fuse at the battery, cover terminals
solder splash in the eye                4     1  safety glasses
scope ground clip on mains part         3     0  no mains circuits on the bench at all

The scores multiply likelihood and severity on a 1 to 3 scale. Notice the last row: the control is elimination, the strongest kind. Organisations use their own matrices; what matters is that you write hazards and controls down before you start.

Guided lab: write the risk assessment for your bench

Hand calculation. List every energy source on your bench with its worst-case voltage and current: for example the bench supply (24 V24\ \text{V} maximum, current limit 0.1 A0.1\ \text{A}), a 9 V9\ \text{V} battery (short-circuit current a few amperes), the soldering iron (tip over 300 ∘C300\,^\circ\text{C}). Classify each voltage with the code above.

Simulation. Add your own rows to tasks and choose controls that bring every score down to 2 or less.

What you would check. Before each session: supply output off, current limit set, leads undamaged, no mains-connected item in the build, scope ground clip plan written down, first-aid and the emergency switch-off known. Record the checklist and its date in your lab notebook.

Hazards and safe setup

  • No mains work, no opened mains appliances or supplies, no salvaged mains parts.
  • A clear, dry bench, no liquids, no metal jewellery on hands and wrists.
  • One hand on the instrument, the other away from the circuit when probing anything you are unsure of; switch off before rewiring.

Pitfalls

  • Believing an RCD makes any shock safe, or that a fuse protects people.
  • Clipping a scope ground lead to a node that is not the circuit's reference while another earth connection exists.
  • Using a meter beyond its CAT rating or with damaged leads.

Practice

  1. What is the peak of 120 V120\ \text{V} rms mains?
  2. Is a 96 V96\ \text{V} DC battery pack within ELV? Is it safe to handle?
  3. Why does an RCD not trip when a person touches line and neutral?
Answer
  1. 1202=170 V120\sqrt{2} = 170\ \text{V}.
  2. Yes, below 120 V120\ \text{V} ripple-free DC; but it can still give a shock with wet hands and its short-circuit current can cause severe burns and fire. It is not a beginner's bench source.
  3. All the current that leaves on line returns on neutral, so line and neutral currents balance and there is no residual current to earth.

Test yourself

What are the ELV limits of IEC 61140 (as of 2026)?

  1. 12 V12\ \text{V} AC and 24 V24\ \text{V} DC
  2. 50 V50\ \text{V} AC rms and 120 V120\ \text{V} ripple-free DC
  3. 230 V230\ \text{V} AC
  4. 1000 V1000\ \text{V} AC and 1500 V1500\ \text{V} DC

Why is the ground clip of a mains-powered oscilloscope at earth potential?

  1. Because the probe contains a battery
  2. Because the scope is a Class I instrument whose BNC shells are bonded to protective earth through the mains plug
  3. Because the circuit under test is earthed
  4. It is not; it floats

Which device can protect a person against a line-to-earth shock?

  1. A fuse
  2. A miniature circuit breaker
  3. A 30 mA30\ \text{mA} residual current device
  4. A surge protector

What does the 'CAT III 600 V' marking on a multimeter tell you?

  1. It may be used on any circuit up to 600 V
  2. It is designed to survive the transient overvoltages of building installations up to 600 V, as defined by IEC 61010
  3. It measures currents up to 600 mA
  4. It is waterproof