How Electric Current Harms the Body
People say "it's the volts that jolt, but the mills that kill". The second half is right: what harms you is the current through your body, how long it flows and which way it goes. The voltage matters because, together with the impedance of your skin and tissue, it decides that current. This lesson explains the physiological effects of current, the threshold ranges published in the IEC standard on effects of current on people and animals, why body impedance varies so much, and why the rest of this course works only at low, isolated, current-limited voltages. The everyday rules are in Electrical Safety of School Physics; this is the engineering view behind them. It is a calculation-only lesson: nothing here is ever tested on a person.
The idea: current, time and path
Current through tissue does three kinds of damage:
- Stimulation of nerves and muscles. From about half a milliampere at mains frequency you feel it; a few milliamperes more and the muscles of the hand contract so strongly that you may be unable to let go of the conductor, so the exposure continues.
- Disturbance of the heart. A current through the chest during the vulnerable part of the heartbeat can trigger ventricular fibrillation: the heart quivers instead of pumping, and without defibrillation that is fatal within minutes. Breathing can also stop when the chest muscles are held in contraction.
- Heating and burns. Power is released where the current density is high (at the contact points) and inside the tissue along the path. Arcs from high-energy sources burn at thousands of degrees without any current through the body at all.
Secondary injuries are common too: a startle reaction at a harmless current can make you fall from a ladder or pull your hand into a sharp edge.
Theory: threshold ranges from IEC 60479-1
The international reference is IEC 60479-1, Effects of current on human beings and livestock, Part 1: General aspects (edition 1.0, 2018, current in 2026; it replaced the technical specification IEC TS 60479-1:2005 with its amendment 1 of 2016, from which the values below are widely quoted; check the current text before relying on any number). For alternating current of 15 to 100 Hz flowing from the left hand to the feet, it divides the current–duration plane into four zones. The current boundaries depend strongly on the duration; the values below are the rough ranges you should remember, not a design tool:
| Zone | Current range (AC 15–100 Hz) | Typical effects |
|---|---|---|
| AC-1 | below about (curve a) | may be felt, normally no reaction |
| AC-2 | from about to curve b, about for long exposures (higher for very short ones) | felt clearly, involuntary twitching, usually no harmful effect |
| AC-3 | from curve b to curve c1 | strong muscle contractions, possible inability to let go, difficult breathing, reversible heart disturbances; effects grow with current and time |
| AC-4 | above curve c1: very roughly to for exposures of a second or more, rising to several hundred milliamperes for exposures shorter than about | ventricular fibrillation becomes possible, its probability rising beyond curves c2 and c3; cardiac and respiratory arrest, burns |
The let-go threshold is often quoted as about to for adults; it varies from person to person, and the standard uses about as a general value. Two consequences for engineers follow. First, the window between "I can feel it" and "I cannot let go" is only a factor of about ten. Second, a current that keeps flowing because the victim cannot let go moves up the duration axis, towards fibrillation. That is why protective devices are specified by disconnection time as well as current; see Safe Bench Practice.
Direct current is treated in the same specification with higher thresholds: perception around , no defined let-go threshold (DC is felt mostly when it is switched on and off), and a fibrillation threshold for long exposures several times higher than for AC. "Higher" does not mean "safe": DC at a few tens of volts can still cause shocks and burns, and DC arcs are harder to extinguish.
The path matters through how much current crosses the heart. The standard gives heart-current factors to compare paths: hand-to-hand and hand-to-feet paths cross the chest; a path through one finger to the next does not.
Body impedance
Ohm's law with the body's impedance gives the current:
is not a constant. The skin is the largest part of it while it is dry and intact; the inside of the body is a few hundred ohms. IEC 60479-1 tabulates for large contact areas, hand to hand: the median is a few kilohms at and falls to roughly to at mains voltages, because higher voltage breaks down the skin. Water, sweat, salt, a large contact area (a gripped rail rather than a fingertip) and broken skin all lower it, and for a given person it can change by a factor of several within minutes. Always calculate with the low end of the range.
Worked example: a "harmless" 24 V AC transformer
Given: someone touches both terminals of a AC transformer secondary with sweaty hands, one terminal in each hand; assume between and . Find: the range of body current and the zone. Solve: to . Check: both ends lie above the let-go range of about to : this is zone AC-3, where the person may not be able to let go. Low voltage is not automatically safe, which is why safety extra-low voltage is defined together with isolation and with lower limits for wet locations.
Code: the same calculation for four situations
# Body current = touch voltage / body impedance, for a range of impedances.
# Zone limits for AC 15-100 Hz and exposures of about 1 s or longer, simplified from
# IEC 60479-1 (curves a, b, c1). Teaching values only: never use them to decide that a touch is safe.
ZONES = [(0.5e-3, "AC-1 may be felt, no reaction"),
(5e-3, "AC-2 felt, twitching, usually no harm"),
(40e-3, "AC-3 cramps, may not let go"),
(float("inf"), "AC-4 fibrillation possible")]
def zone(i):
for limit, name in ZONES:
if i < limit:
return name
cases = [ # (description, touch voltage V AC, assumed body impedance range ohm: high, low)
("12 V AC, dry hands, small contact", 12, 50e3, 10e3),
("25 V AC, dry hands, large contact", 25, 6e3, 2e3),
("50 V AC, wet hands, large contact", 50, 2e3, 1e3),
("230 V AC, hand to hand (calc. only)", 230, 1.5e3, 0.8e3),
]
for text, v, z_hi, z_lo in cases:
i_lo, i_hi = v / z_hi, v / z_lo
print(f"{text:<37} {i_lo * 1e3:7.2f} .. {i_hi * 1e3:6.1f} mA worst case: {zone(i_hi)}")12 V AC, dry hands, small contact 0.24 .. 1.2 mA worst case: AC-2 felt, twitching, usually no harm
25 V AC, dry hands, large contact 4.17 .. 12.5 mA worst case: AC-3 cramps, may not let go
50 V AC, wet hands, large contact 25.00 .. 50.0 mA worst case: AC-4 fibrillation possible
230 V AC, hand to hand (calc. only) 153.33 .. 287.5 mA worst case: AC-4 fibrillation possible
The impedance ranges are assumptions for illustration, chosen in the spirit of the standard's tables. The mains row is a calculation only: it shows why mains work is reserved for qualified people with approved procedures, and never part of this course.
Guided lab: a paper risk check
Hand calculation. For each source on your bench, write the worst-case touch voltage and the lowest plausible body impedance, then . A battery across dry fingertips with of to gives to : zone AC-1 at most. A DC bench supply hand to hand gives about to if you take the impedances in the code (DC impedance is somewhat higher, so this errs on the safe side), well above the DC perception threshold; wet hands push it higher, so keep hands dry and never hold both output terminals.
Simulation. Edit the cases list in the code: add your bench supply at its maximum setting and change the impedance range for wet skin. Notice how the zone changes while the voltage stays the same.
What you would measure. You can safely measure your skin resistance with a battery-powered multimeter on its resistance range, holding one probe tip lightly in each hand: the meter applies only a few volts and microamperes. Dry skin typically reads hundreds of kilohms to a few megohms; damp fingers read much less; readings drift by tens of percent as you press harder. This shows the variability; it does not give the impedance at higher voltages, which is lower still.
Hazards and safe setup
- Resistance range of a battery-powered handheld multimeter only, with the probes connected to nothing else; skip this if you have an implanted medical device. Never measure "body current" from any supply.
- Never use a mains-powered instrument, a bench supply or a signal generator for this.
- Never work on or near mains wiring; if anyone receives a shock, switch off at the source before touching them and call emergency services.
Pitfalls and safety
- "It's only 24 V": wet skin and AC can push the current past the let-go range. Low voltage is a necessary condition for safe bench work, not a sufficient one.
- Thinking a shock you survived proves the source safe: the outcome depends on timing within the heartbeat, path and duration.
- Forgetting burns at low voltage: a ring or a watch strap shorting a car battery heats to glowing in seconds without any current through the body.
- Treating the threshold table as a design tool: real assessments use the standard's curves and the wiring rules derived from them.
Practice
- Find the body current for AC with , and its zone for a long exposure.
- Why can the let-go threshold turn a moderate shock into a fatal one?
- Name three factors that lower body impedance.
Answer
- : right at the AC-3/AC-4 boundary for long exposures, so fibrillation is possible.
- Above it the muscles hold the conductor, so the current flows for longer, and longer exposures have lower fibrillation thresholds.
- Any three of: wet or sweaty skin, a large contact area or firm grip, higher touch voltage, broken skin, salt water.
Test yourself
Which quantity most directly decides the physiological effect of an electric shock?
- The voltage of the source alone
- The current through the body, its duration and its path
- The power rating of the source
- The resistance of the wire
Roughly where does the let-go threshold for AC at 50 Hz lie for adults?
- About
- About to
- About
- There is no such threshold
Why does body impedance fall at higher touch voltages?
- Higher voltage breaks down the skin's resistance
- The body warms up
- Current always rises with the square of voltage
- It does not change
A shock lasts longer. What happens to the current needed for ventricular fibrillation?
- It rises
- It falls
- It stays the same
- Fibrillation only depends on voltage