TExcelTAD
Home › Electrical & Electronic Measurements › AC Bridges: Maxwell, Schering and Wien

AC Bridges: Maxwell, Schering and Wien

An inductor is not just an inductance: its winding has resistance, so it is R+jωLR + j\omega L. A capacitor's dielectric absorbs a little energy each cycle, so it has a loss angle. Measuring the two parts separately, and accurately, was the job of AC bridges for a century, and their balance equations still define how LCR meters, impedance analysers and high-voltage insulation test sets describe components. This lesson generalises the Wheatstone bridge to impedances and works through the three classic circuits.

Phasors and impedance are from Circuit Theory.

The general balance condition

Replace the four resistors by impedances: Z1Z_1 from the source node a to b, Z2Z_2 from b to ground, Z3Z_3 from a to c, Z4Z_4 from c to ground, with a detector between b and c. The detector reads zero when the two dividers give the same phasor:

Z2Z1+Z2=Z4Z3+Z4⟺Z1Z4=Z2Z3\frac{Z_2}{Z_1 + Z_2} = \frac{Z_4}{Z_3 + Z_4} \quad\Longleftrightarrow\quad Z_1 Z_4 = Z_2 Z_3

This is one complex equation, i.e. two real conditions: the magnitudes and the phases must both match,

∣Z1∣∣Z4∣=∣Z2∣∣Z3∣,∠Z1+∠Z4=∠Z2+∠Z3\lvert Z_1 \rvert \lvert Z_4 \rvert = \lvert Z_2 \rvert \lvert Z_3 \rvert, \qquad \angle Z_1 + \angle Z_4 = \angle Z_2 + \angle Z_3

so an AC bridge needs two adjustable elements, and the operator alternates between them until the null is deep. A good bridge design makes the two adjustments independent (each one controls one unknown) and the balance frequency-independent, so harmonics in the source do not spoil the null.

Maxwell a R1 || C1 standard C R2 R3 Lx + Rx unknown D b c Schering a Cx + Rx unknown R3 C2 standard R4 || C4 D b c Wien a R + C series R || C parallel 2 R4 R4 D b c

Maxwell (Maxwell–Wien) bridge: inductance

The unknown inductor Rx+jωLxR_x + j\omega L_x sits in arm 4; arms 2 and 3 are resistors; arm 1 is R1R_1 in parallel with a standard capacitor C1C_1. With Z1=1/(1/R1+jωC1)Z_1 = 1/(1/R_1 + j\omega C_1), the balance Z4=Z2Z3/Z1Z_4 = Z_2 Z_3/Z_1 gives

Rx+jωLx=R2R3(1R1+jωC1)⟹Lx=R2R3C1,Rx=R2R3R1R_x + j\omega L_x = R_2 R_3 \left(\frac{1}{R_1} + j\omega C_1\right) \quad\Longrightarrow\quad L_x = R_2 R_3 C_1, \qquad R_x = \frac{R_2 R_3}{R_1}

Both results are free of ω\omega: the balance holds at every frequency. C1C_1 sets LxL_x and R1R_1 sets RxR_x, so the adjustments are independent. Using a capacitor as the standard is the trick: precision capacitors are far closer to ideal than any reference inductor. The quality factor is Q=ωLx/Rx=ωC1R1Q = \omega L_x/R_x = \omega C_1 R_1; for high-QQ coils R1R_1 becomes impractically large and the Hay bridge (series R1C1R_1 C_1) is used instead.

Worked example: a 10 mH coil

Given: a Maxwell bridge at 1 kHz1\ \text{kHz} with R2=R3=1.000 kΩR_2 = R_3 = 1.000\ \text{k}\Omega, balanced at C1=10.00 nFC_1 = 10.00\ \text{nF} and R1=40.0 kΩR_1 = 40.0\ \text{k}\Omega.

Find: LxL_x, RxR_x and QQ at 1 kHz1\ \text{kHz}.

Solve:

Lx=1000 Ω×1000 Ω×10.00 nF=10.00 mHRx=1000 Ω×1000 Ω40.0 kΩ=25.0 ΩQ=2π×1000 Hz×10.00 mH25.0 Ω=2.51\begin{aligned} L_x &= 1000\ \Omega \times 1000\ \Omega \times 10.00\ \text{nF} = 10.00\ \text{mH} \\ R_x &= \frac{1000\ \Omega \times 1000\ \Omega}{40.0\ \text{k}\Omega} = 25.0\ \Omega \\ Q &= \frac{2\pi \times 1000\ \text{Hz} \times 10.00\ \text{mH}}{25.0\ \Omega} = 2.51 \end{aligned}

Check: units: Ω2⋅F=Ω⋅s=H\Omega^2 \cdot \text{F} = \Omega \cdot \text{s} = \text{H}. A small coil with 25 Ω25\ \Omega of copper and Q≈2.5Q \approx 2.5 at 1 kHz1\ \text{kHz} is plausible for a few hundred turns of thin wire. ngspice confirms the null and shows how far off a 10 %10\,\% error in either adjustment puts the detector, for 1 V1\ \text{V} of drive:

bash · try it yourself
cat > maxwell.cir <<'EOF'
* Maxwell inductance bridge at 1 kHz: unknown 10 mH with 25 ohm series resistance
V1 a 0 DC 0 AC 1
R1 a b 40k
C1 a b 10n
R2 b 0 1k
R3 a c 1k
Rx c x 25
Lx x 0 10m
.control
ac lin 1 1k 1k
let vd = mag(v(b) - v(c))
echo "balanced (R1 = 40k, C1 = 10n):"
if vd lt 1e-12
  echo "vd below 1e-12 V: null"
end
alter C1 = 11n
ac lin 1 1k 1k
let vd = mag(v(b) - v(c))
echo "C1 = 11n:"
print vd
alter C1 = 10n
alter R1 = 30k
ac lin 1 1k 1k
let vd = mag(v(b) - v(c))
echo "R1 = 30k:"
print vd
.endc
.end
EOF
ngspice -b maxwell.cir 2>&1 | grep -E '^(vd|balanced|C1|R1)'
balanced (R1 = 40k, C1 = 10n):
vd below 1e-12 V: null
C1 = 11n:
vd = 5.955698e-03
R1 = 30k:
vd = 7.838603e-03

Simulation. The lab solves the same bridge for AC. E1 copies vb−vcv_b - v_c to node d. At the starting value C1=11 nFC_1 = 11\ \text{nF} node d reads 5.96 mV5.96\ \text{mV} at 1 kHz1\ \text{kHz} and more at higher frequencies, because the jωj\omega term is what is off. Slide C1C_1 to 10 nF10\ \text{nF}: d drops to picovolts across the whole frequency axis (the balance is frequency-independent; the tiny residual is the solver's gmin conductance).

0.000.020.04101001k10k100kf (Hz)|V| (V)|V(d)|phasors at f = 1.000 kHz (magnitude @ phase)V(a)1.00 V @ 0.0 degV(b)71.5 mV @ 66.3 degV(c)65.8 mV @ 64.8 degV(x)61.2 mV @ 86.5 degV(d)5.96 mV @ 82.6 degI(V1)1.00 mA @ -179.7 degI(R1)24.3 uA @ -3.9 degI(C1)67.3 uA @ 86.1 degI(R2)71.5 uA @ 66.3 degI(R3)974 uA @ -3.5 degI(Rx)974 uA @ -3.5 degI(Lx)974 uA @ -3.5 degI(E1)5.96 nA @ -97.4 degI(Rd)5.96 nA @ 82.6 deg

Schering bridge: capacitance and loss

The unknown capacitor is modelled as CxC_x in series with a loss resistance RxR_x; its dissipation factor is D=tan⁡δ=ωCxRxD = \tan\delta = \omega C_x R_x. In the Schering bridge the unknown is in arm 1 (a–b), R3R_3 in arm 2 (b–ground), a lossless standard capacitor C2C_2 in arm 3 (a–c) and R4∥C4R_4 \parallel C_4 in arm 4 (c–ground). Balance gives

Cx=C2 R4R3,Rx=R3 C4C2,D=ωR4C4C_x = C_2\,\frac{R_4}{R_3}, \qquad R_x = R_3\,\frac{C_4}{C_2}, \qquad D = \omega R_4 C_4

R4R_4 sets CxC_x, C4C_4 sets DD directly. Because the standard capacitor and the unknown take the high-voltage side and the adjustable arms sit near ground, the Schering bridge became the standard method for dielectric loss of insulation at high voltage (cables, bushings, transformers). That use is professional high-voltage work and is a concept only here; the same bridge works at a few volts on the bench.

Wien bridge: a frequency-selective null

With RR and CC in series in arm 1 and R∥CR \parallel C in arm 2, and a resistive ratio R3=2R4R_3 = 2R_4 on the other side, the bridge balances at one frequency only:

f0=12πRCf_0 = \frac{1}{2\pi R C}

The Wien bridge measures frequency (adjust RR or CC for a null), notches out the fundamental in classic distortion analysers (what remains is the harmonics and noise), and, with an amplifier, becomes the Wien-bridge oscillator.

python · try it yourself
import numpy as np

def detector(Za_b, Zb_0, Za_c, Zc_0, V=1.0):
    """Bridge fed with V at node a: |v_b - v_c|."""
    return abs(V * Zb_0 / (Za_b + Zb_0) - V * Zc_0 / (Za_c + Zc_0))

par = lambda Z1, Z2: Z1 * Z2 / (Z1 + Z2)
f = 1000.0
w = 2 * np.pi * f

# Maxwell bridge: arm a-b = R1 || C1, b-0 = R2, a-c = R3, c-0 = unknown Rx + j w Lx
R2 = R3 = 1e3
R1, C1 = 40e3, 10e-9                          # settings at balance
Lx, Rx = R2 * R3 * C1, R2 * R3 / R1
print(f"Maxwell: Lx = R2 R3 C1 = {1e3 * Lx:.3f} mH, Rx = R2 R3 / R1 = {Rx:.2f} ohm, Q(1 kHz) = {w * Lx / Rx:.3f}")
for label, r1, c1 in (("C1 = 11 nF", 40e3, 11e-9), ("R1 = 30 kohm", 30e3, 10e-9)):
    Z1 = par(r1, 1 / (1j * w * c1))
    print(f"  off balance, {label}: |vd| = {1e3 * detector(Z1, R2, R3, 25 + 1j * w * 10e-3):.4f} mV per volt")

# Schering bridge: arm a-b = unknown (Cx + Rx series), b-0 = R3, a-c = C2 (standard), c-0 = R4 || C4
C2, R3s, R4, C4 = 100e-12, 1e3, 4.7e3, 67.7e-12
Cx, Rxs = C2 * R4 / R3s, R3s * C4 / C2
print(f"Schering: Cx = C2 R4 / R3 = {1e12 * Cx:.1f} pF, Rx = R3 C4 / C2 = {Rxs:.0f} ohm, "
      f"D = w R4 C4 = {w * R4 * C4:.5f}")

# Wien bridge: a-b = R + C series, b-0 = R || C, a-c = R3, c-0 = R4 with R3 = 2 R4
R, C = 10e3, 15.915e-9
f0 = 1 / (2 * np.pi * R * C)
print(f"Wien: f0 = 1/(2 pi R C) = {f0:.1f} Hz")
for fx in (500.0, 900.0, f0, 1100.0, 2000.0):
    wx = 2 * np.pi * fx
    vd = detector(R + 1 / (1j * wx * C), par(R, 1 / (1j * wx * C)), 2e3, 1e3)
    print(f"  f = {fx:7.1f} Hz: |vd| = {1e3 * vd:7.3f} mV per volt")
Maxwell: Lx = R2 R3 C1 = 10.000 mH, Rx = R2 R3 / R1 = 25.00 ohm, Q(1 kHz) = 2.513
  off balance, C1 = 11 nF: |vd| = 5.9557 mV per volt
  off balance, R1 = 30 kohm: |vd| = 7.8386 mV per volt
Schering: Cx = C2 R4 / R3 = 470.0 pF, Rx = R3 C4 / C2 = 677 ohm, D = w R4 C4 = 0.00200
Wien: f0 = 1/(2 pi R C) = 1000.0 Hz
  f =   500.0 Hz: |vd| = 149.077 mV per volt
  f =   900.0 Hz: |vd| =  23.406 mV per volt
  f =  1000.0 Hz: |vd| =   0.000 mV per volt
  f =  1100.0 Hz: |vd| =  21.162 mV per volt
  f =  2000.0 Hz: |vd| = 149.065 mV per volt

The off-balance Maxwell values match ngspice to all printed digits. The Wien detector falls to zero only at f0f_0; a 10 %10\,\% frequency error leaves about 2 %2\,\% of the drive, which is why the null is a sensitive frequency indicator.

Guided lab: balance a Maxwell bridge on the bench

Hand calculation. For a 10 mH10\ \text{mH} inductor (check its datasheet DC resistance, say 2020 to 30 Ω30\ \Omega) and R2=R3=1 kΩR_2 = R_3 = 1\ \text{k}\Omega: C1=10 nFC_1 = 10\ \text{nF} and R1≈33R_1 \approx 33 to 50 kΩ50\ \text{k}\Omega.

Simulation. Use the lab with your inductor's values; the lab's slider is C1C_1 only, so account for a different coil resistance through R1=R2R3/RxR_1 = R_2 R_3/R_x (a larger RxR_x needs a smaller R1R_1).

What you would measure. Drive the bridge from a function generator at 1 kHz1\ \text{kHz}, 2 Vpp2\ \text{V}_\text{pp}; use a capacitance decade (or switched 11, 2.22.2, 4.7 nF4.7\ \text{nF} capacitors) for C1C_1 and a 100 kΩ100\ \text{k}\Omega potentiometer in series with 10 kΩ10\ \text{k}\Omega for R1R_1. Watch the detector with a scope in differential mode (channel 1 minus channel 2, both probes 10x) or with a battery-powered DMM on AC volts. Expect the null to fall from tens of millivolts to below a millivolt, limited by stray capacitance and the generator's harmonics; your LxL_x should be within the inductor's tolerance (often ±10 %\pm 10\,\%).

Hazards and safe setup. Generator signal levels only. The detector is floating: do not connect a grounded scope probe's clip to node b or c, it would short an arm through earth.

Pitfalls

  • Adjusting only one element and expecting a null: two conditions need two adjustments.
  • Ignoring stray capacitance to ground at high frequencies (a Wagner earth or a shielded transformer ratio arm is the classic cure).
  • Grounding the detector.
  • Reading a Schering balance as "capacitance only": the second adjustment is the loss, often the quantity you need.

Practice

  1. A Maxwell bridge with R2=R3=500 ΩR_2 = R_3 = 500\ \Omega balances at C1=47 nFC_1 = 47\ \text{nF}, R1=10 kΩR_1 = 10\ \text{k}\Omega. Find LxL_x and RxR_x.
  2. A Wien bridge uses R=4.7 kΩR = 4.7\ \text{k}\Omega and C=10 nFC = 10\ \text{nF}. Where is its null?
Answer
  1. Lx=500×500×47×10−9=11.75 mHL_x = 500 \times 500 \times 47 \times 10^{-9} = 11.75\ \text{mH}; Rx=250 000/10 000=25 ΩR_x = 250\,000/10\,000 = 25\ \Omega.
  2. f0=1/(2π×4700×10−8)=3.39 kHzf_0 = 1/(2\pi \times 4700 \times 10^{-8}) = 3.39\ \text{kHz}.

Test yourself

Why does an AC bridge need two adjustable elements?

  1. one for each supply terminal
  2. the complex balance equation is two real conditions
  3. to double the sensitivity
  4. to cancel thermal EMFs

In a Maxwell bridge the unknown inductance is measured against

  1. a standard inductor
  2. a standard capacitor
  3. a frequency standard
  4. a Zener reference

The Schering bridge is best known for measuring

  1. inductance of coils
  2. capacitance and dielectric loss (tan delta)
  3. frequency
  4. low resistance

A Wien bridge with equal R and C balances at

  1. f=RCf = RC
  2. f=1/(2πRC)f = 1/(2\pi R C)
  3. every frequency
  4. f=2πRCf = 2\pi R C