Strain Gauges, Load Cells and Pressure Sensors
A kitchen scale, a bridge-monitoring system, a car's brake-pressure sensor and an aircraft wing test all measure the same thing underneath: a tiny change in resistance of a metal foil or a silicon element when it is stretched. A strain of microstrain ( elongation) changes a foil gauge's resistance by about , which a Wheatstone bridge turns into about a millivolt. Getting from that millivolt to a weight or pressure good to is a lesson in bridges, excitation and temperature compensation.
The strain gauge
Strain is relative elongation, , dimensionless and quoted in microstrain (). A bonded foil gauge follows the surface it is glued to, and its resistance changes as
with a gauge factor for metal foils (from the change of length and cross-section plus a small resistivity change) and to for semiconductor gauges (piezoresistive, much larger but temperature-sensitive and non-linear). Standard resistances are and (also for low power). Steel at a working stress of () is strained by , so .
Bridge configurations
With excitation and one active gauge (a quarter bridge), the bridge output is
slightly non-linear because the active arm's current changes. Mounting gauges where the strains are opposite (top and bottom of a bending beam) and placing them in adjacent arms gives a half bridge with twice the output, exactly linear; four active gauges make a full bridge with four times the output, the standard for load cells. Adjacent arms also cancel common effects: if both gauges warm up equally, their resistance changes cancel. In a quarter bridge a passive dummy gauge on an unstrained piece of the same material does that job.
Other error sources: lead resistance in series with a single gauge (use a three-wire connection, which puts one lead in each adjacent arm), excitation drift (measure ratiometrically, below), self-heating of the gauge (limit to a few volts for small gauges on poor heat sinks), and the thermal output when the gauge alloy's expansion does not match the material ("self-temperature-compensated" gauges are matched to steel or aluminium).
Worked example: a quarter bridge at 500 microstrain
Given: , , , .
Find: the exact and linearised outputs and the non-linearity.
Solve: , .
Check: about per microstrain, so a resolution needs a front end with a few microvolts of noise and drift: an instrumentation amplifier or a high-resolution sigma-delta ADC with a programmable gain (Signal Conditioning). The program compares the configurations:
import numpy as np
Vex, R, GF = 5.0, 350.0, 2.1
print("strain (ue) quarter exact quarter linear nonlin half (bending) full")
for ue in (100, 500, 1000, 5000):
x = GF * ue * 1e-6 # dR/R of one gauge
quarter = Vex * (R * (1 + x) / (R * (1 + x) + R) - 0.5)
lin = Vex * x / 4
half = Vex * x / 2 # +x and -x gauges in adjacent arms: exactly linear
full = Vex * x # four active gauges
print(f"{ue:10d} {1e3 * quarter:12.4f} mV {1e3 * lin:11.4f} mV {100 * (quarter / lin - 1):7.3f} % "
f"{1e3 * half:10.4f} mV {1e3 * full:9.4f} mV")
# Apparent strain from temperature: gauge alloy not matched to the steel, 2 ppm/K mismatch over 10 K
dT, mismatch = 10.0, 2e-6
print(f"10 K with a 2 ppm/K mismatch looks like {1e6 * mismatch * dT:.0f} ue in a quarter bridge "
f"(cancelled by a dummy gauge in the adjacent arm)")
# Load cell: 2 mV/V rated output, 10 kg capacity, 5 V excitation, 24-bit ADC with gain 128, ratiometric reference
FS_mV = 2.0 * Vex
lsb = (Vex / 128) / 2**23 # +/- Vref/gain over 2^24 codes
print(f"load cell full scale {FS_mV:.1f} mV = 10 kg; 1 g = {FS_mV / 10000 * 1000:.2f} uV; "
f"ADC LSB {1e9 * lsb:.1f} nV")strain (ue) quarter exact quarter linear nonlin half (bending) full
100 0.2625 mV 0.2625 mV -0.010 % 0.5250 mV 1.0500 mV
500 1.3118 mV 1.3125 mV -0.052 % 2.6250 mV 5.2500 mV
1000 2.6222 mV 2.6250 mV -0.105 % 5.2500 mV 10.5000 mV
5000 13.0565 mV 13.1250 mV -0.522 % 26.2500 mV 52.5000 mV
10 K with a 2 ppm/K mismatch looks like 20 ue in a quarter bridge (cancelled by a dummy gauge in the adjacent arm)
load cell full scale 10.0 mV = 10 kg; 1 g = 1.00 uV; ADC LSB 4.7 nV
Load cells and ratiometric measurement
A load cell is a machined metal element with a full bridge of gauges, calibrated by its maker. Its sensitivity is the rated output in mV/V: a , cell excited at gives at , so is . Datasheets add combined error (non-linearity and hysteresis, e.g. of rated output), creep (output drift under constant load over 30 minutes), zero and span temperature coefficients, and the safe and ultimate overloads.
Because the output is proportional to , the best way to read a bridge is ratiometrically: use the excitation voltage (or a divided copy of it) as the ADC's reference. Then the code is proportional to , the quantity the bridge actually defines, and drift or noise of the excitation cancels, the same correlation argument as in Propagation of Uncertainty. Six-wire load cells add sense leads that report the excitation at the cell itself, removing the cable's voltage drop (the Kelvin idea again).
Pressure sensors
- Piezoresistive (MEMS): four silicon resistors diffused into a thin silicon diaphragm, wired as a full bridge; large signal, but strong temperature dependence, compensated by the maker (in "amplified" sensors, by an internal ASIC that outputs to or a digital value).
- Capacitive: the diaphragm is one plate of a capacitor; low power and good stability.
- Strain-gauge-on-diaphragm (thin film or bonded foil): industrial transmitters, often with to outputs.
- References: gauge (relative to atmosphere), absolute (relative to vacuum), differential (between two ports).
The datasheet line from Static Characteristics (total error band, thermal zero and span shifts) applies to all of them.
Guided lab: amplify a quarter bridge
Hand calculation. A quarter bridge at with (, about at GF 2.1) gives ; an instrumentation amplifier with gain gives .
Simulation. Rg is the active gauge; E1 is an instrumentation amplifier with gain 100 between the two midpoints. At node out reads . Slide Rg between and to see the output cross zero at and change sign with compression.
What you would measure. Use a cheap to bar load cell with its HX711-class 24-bit ADC board (or an instrumentation amplifier into a DMM). With excitation, expect a zero offset of a fraction of a millivolt, about per rated load for these cells (check the label), linear readings with known weights within about , and visible creep: put a weight on and watch the last digits drift for minutes. Warm the cell with your hand: the zero moves.
Hazards and safe setup. from the board or a current-limited supply. Do not overload the cell beyond its safe overload (often to ); mount it on its intended screw holes.
Pitfalls
- Quarter bridges without a dummy gauge: every temperature change is an apparent strain.
- Measuring the bridge against a fixed reference while the excitation drifts (not ratiometric).
- Ignoring lead resistance in 2-wire quarter bridges (it adds to the gauge and desensitises the bridge).
- Forgetting creep and hysteresis when calibrating a scale with a single quick load.
Practice
- A full bridge of four gauges, GF , , with on all four (two , two ). What is ?
- A load cell of is excited at . What output does give?
Answer
- .
- Full scale ; .
Test yourself
A foil strain gauge has a gauge factor of about
- 0.2
- 2
- 20
- 200
A half bridge with gauges on opposite faces of a bending beam, in adjacent arms, compared with a quarter bridge
- has half the output
- has twice the output and cancels equal temperature changes
- is more non-linear
- needs no excitation
Ratiometric measurement of a bridge means
- measuring the bridge twice
- using the excitation voltage as the ADC reference
- measuring at a ratio of two frequencies
- dividing by the gauge factor
A 2 mV/V load cell at 5 V excitation produces at full load
- 2 mV
- 5 mV
- 10 mV
- 2.5 mV