TExcelTAD
Home › Electrical Machines & Transformers › Armature Reaction and Commutation

Armature Reaction and Commutation

The EMF equation of the previous lesson assumed that the flux under each pole is set by the field winding alone. On load that is not true: the armature current is itself a winding with ampere-turns, and its magnetic field adds to the main field. This armature reaction distorts the flux under the poles, moves the magnetic neutral away from the brushes and, once the pole tips saturate, reduces the flux per pole. At the same time, every coil passing under a brush must reverse its current in well under a millisecond, against its own inductance. If the reversal is incomplete when the segment leaves the brush, the remaining energy goes into a spark. Brush wear, radio noise and, in bad cases, a flashover around the commutator follow. This lesson puts numbers on both effects and shows the three remedies: brush shift, interpoles and compensating windings.

The armature MMF

0 field MMF 2000 A-t armature MMF, +-750 A-t 1475 A-t (weak tip) 2525 A-t (strong tip) brush axisbrush axis pole tippole tip one pole pitch, Ia = 50 A

Each armature conductor carries Ic=Ia/aI_c = I_a/a, and the current direction changes at the brushes. The armature therefore acts like a winding whose axis lies along the brush axis, at 90∘90^\circ electrical to the field axis. Its MMF grows linearly from one brush to the next and peaks at the brush axis with

Fa=ZIc2p=ZIa2ap  ampere-turns per poleF_a = \frac{Z I_c}{2p} = \frac{Z I_a}{2 a p}\ \ \text{ampere-turns per pole}

Under a pole the armature MMF adds to the field MMF at one tip and subtracts at the other: it is cross-magnetising. Three consequences:

  1. Distortion and neutral shift. The point of zero flux density, the magnetic neutral axis, moves away from the geometric neutral, forwards (in the direction of rotation) in a generator and backwards in a motor. Coils at the brushes now have EMF in them while they are short-circuited.
  2. Demagnetisation through saturation. If the iron were linear, the extra flux at one tip would cancel the loss at the other. The strengthened tip saturates, so it gains less than the weak tip loses: the net flux per pole falls, and with it EaE_a (generator voltage drops) or the motor speeds up (less flux, see DC Motors).
  3. High coil voltages under the strong tip. Coils there cut a high flux density, so the voltage between adjacent commutator segments rises locally; above roughly 30 to 40 V between segments, an arc between segments can grow into a flashover around the commutator.

Commutation

A coil under the brush is short-circuited while its current reverses from +Ic+I_c to −Ic-I_c. The commutation time is the time a segment takes to pass under the brush:

tc=wbvc,vc=πDcn60t_c = \frac{w_b}{v_c}, \qquad v_c = \pi D_c \frac{n}{60}

with brush width wbw_b and commutator diameter DcD_c. The coil's self- and mutual inductance LcL_c opposes the reversal with the reactance voltage

er≈Lc2Ictce_r \approx L_c \frac{2 I_c}{t_c}

If nothing cancels ere_r, the current lags behind ("under-commutation") and is still flowing when the segment leaves the brush: a spark at the trailing brush edge. Carbon brushes help because their contact resistance pushes the current towards linear reversal (resistance commutation), but in larger machines a voltage of the opposite sign must be induced in the commutating coil.

The remedies

Remedy How Good for Drawback
Brush shift move the brushes to the new magnetic neutral (forward in a generator, back in a motor) small machines at one load correct for one load and one direction only; adds demagnetising MMF
Interpoles (commutating poles) narrow poles on the geometric neutral, winding in series with the armature, so their MMF tracks IaI_a almost all DC machines above about 1 kW more copper; set for one design
Compensating winding conductors in the main pole faces, in series with the armature, opposing the armature MMF under the pole large or fast-reversing machines (rolling mills) expensive; also needs interpoles

An interpole must first cancel the armature MMF at the brush axis, FaF_a, and then add enough MMF to drive a commutating flux across its own gap, whose speed-dependent EMF cancels ere_r. Because both FaF_a and ere_r are proportional to IaI_a, a series winding keeps the balance at every load.

Worked example: armature reaction and interpole turns

Given: the 4-pole lap machine of the last lesson: Z=480Z = 480, a=4a = 4, Ia=50 AI_a = 50\ \text{A}, field 20002000 A-turns per pole, pole arc 70 % of the pitch. Commutator Dc=0.20 mD_c = 0.20\ \text{m} at 1200 rpm1200\ \text{rpm}, brush width 10 mm10\ \text{mm}, commutating-coil inductance Lc=0.15 mHL_c = 0.15\ \text{mH}. The interpole gap needs 250250 A-turns to produce the commutating flux.

Find: FaF_a, the MMF at the pole tips, the reactance voltage, the interpole turns, and the compensating-winding MMF.

Solve:

Fa=480⋅50 A2⋅4⋅4=750 A-turns per poleFtips=2000∓0.7⋅750=1475 and 2525 A-turnsvc=π⋅0.20 m⋅20 s−1=12.57 m/s,tc=0.010 m12.57 m/s=0.796 mser=0.15 mH⋅2⋅12.5 A0.796 ms=4.71 VNip=750+250 A-turns50 A=20 turns per interpole\begin{aligned} F_a &= \frac{480 \cdot 50\ \text{A}}{2 \cdot 4 \cdot 4} = 750\ \text{A-turns per pole} \\ F_\text{tips} &= 2000 \mp 0.7 \cdot 750 = 1475\ \text{and}\ 2525\ \text{A-turns} \\ v_c &= \pi \cdot 0.20\ \text{m} \cdot 20\ \text{s}^{-1} = 12.57\ \text{m/s}, \qquad t_c = \frac{0.010\ \text{m}}{12.57\ \text{m/s}} = 0.796\ \text{ms} \\ e_r &= 0.15\ \text{mH} \cdot \frac{2 \cdot 12.5\ \text{A}}{0.796\ \text{ms}} = 4.71\ \text{V} \\ N_\text{ip} &= \frac{750 + 250\ \text{A-turns}}{50\ \text{A}} = 20\ \text{turns per interpole} \end{aligned}

A compensating winding covering the pole face would carry 0.7⋅750=5250.7 \cdot 750 = 525 A-turns per pole. It cancels the armature MMF only under the pole arc, so the interpoles still need the remaining 750−525=225750 - 525 = 225 A-turns plus the 250250 for their own gap: 475475 A-turns, 9.59.5 turns (10 in practice) instead of 20.

Check: ere_r of a few volts is typical; a carbon brush's contact drop (about 1 V per brush) cannot absorb it alone, so the interpoles are needed. The tip MMFs differ by 2⋅525=10502 \cdot 525 = 1050 A-turns, which is the armature MMF swing across the pole arc.

In Python: flux per pole on load

The gap-and-teeth flux density saturates; model it as B=Bstanh⁡(F/F0)B = B_s \tanh(F/F_0) and average it over the pole arc.

python · try it yourself
import numpy as np

# MMF and gap flux density along one pole pitch of a 4-pole machine (x = 0..1 pole pitch)
Z, a, p = 480, 4, 4
Ff = 2000.0                                  # field ampere-turns per pole
x = np.linspace(0, 1, 2001)
under_pole = (x > 0.15) & (x < 0.85)         # pole arc = 70 % of the pitch
Bs, F0 = 1.2, 1500.0                         # saturating gap + teeth curve: B = Bs tanh(F/F0)
B = lambda F: Bs * np.tanh(F / F0)
flux0 = np.where(under_pole, B(Ff), 0).mean()
print(f"field MMF {Ff:.0f} A-turns per pole, no-load pole-face B = {B(Ff):.3f} T")
print("  Ia    Fa     B weak tip  B strong tip  flux / no-load flux")
for Ia in (25, 50, 75, 100):
    Fa = Z * (Ia / a) / (2 * p)              # armature ampere-turns per pole (peak, at the brush axis)
    fa = Fa * (2 * x - 1)                    # triangular: -Fa at one brush axis, +Fa at the next
    flux = np.where(under_pole, B(Ff + fa), 0).mean()
    print(f"{Ia:4d} A {Fa:5.0f}    {B(Ff - 0.7*Fa):.3f} T    {B(Ff + 0.7*Fa):.3f} T    {flux/flux0:.4f}")

# commutation: reactance voltage of the coil being reversed, at Ia = 50 A
D, n, wb, Lc, Ia = 0.20, 1200, 0.010, 0.15e-3, 50
v = np.pi * D * n / 60                       # commutator surface speed
tc = wb / v                                  # time a segment spends under the brush
Ic = Ia / a
print(f"surface speed {v:.2f} m/s, commutation time {tc*1e3:.3f} ms")
print(f"coil current {Ic:+.1f} A -> {-Ic:+.1f} A, reactance voltage L*2Ic/tc = {Lc*2*Ic/tc:.2f} V")
field MMF 2000 A-turns per pole, no-load pole-face B = 1.044 T
  Ia    Fa     B weak tip  B strong tip  flux / no-load flux
  25 A   375    0.985 T    1.088 T    0.9975
  50 A   750    0.905 T    1.120 T    0.9900
  75 A  1125    0.802 T    1.143 T    0.9774
 100 A  1500    0.672 T    1.160 T    0.9596
surface speed 12.57 m/s, commutation time 0.796 ms
coil current +12.5 A -> -12.5 A, reactance voltage L*2Ic/tc = 4.71 V

The weak tip loses 0.139 T0.139\ \text{T} at 50 A50\ \text{A} while the strong tip gains only 0.076 T0.076\ \text{T}; the flux per pole falls by 1 % at rated current and by 4 % at twice rated. Small as it looks, a 4 % flux loss raises a motor's speed by about 4 % at the moment the load is heaviest, which can make a shunt motor unstable. A compensating winding removes the effect.

Guided lab: see commutation in a small motor

Hand calculation. For a toy motor with a 6 mm6\ \text{mm} commutator at 6000 rpm6000\ \text{rpm} and a 1.5 mm1.5\ \text{mm} brush, vc=1.88 m/sv_c = 1.88\ \text{m/s} and tc=0.80 mst_c = 0.80\ \text{ms}; a 3-segment commutator switches 3⋅2=63 \cdot 2 = 6 times per revolution, 600600 events per second.

Simulation. Run the Python cell with a smaller pole arc or a larger FaF_a to see how quickly saturation turns distortion into flux loss.

What you would measure. Run a small brushed motor (rated at most 12 V12\ \text{V}) from a current-limited bench supply through a 0.1 Ω0.1\ \Omega shunt, with the scope across the shunt. Expect a current ripple at the commutation frequency (600 Hz600\ \text{Hz} in the example above, ±5 %\pm 5\ \% with speed) with sharp spikes at each switching edge; load the shaft lightly with your fingers on a felt pad (or a friction brake) and the spikes grow. In a dark room you can see blue sparking at the brushes through the end-cap slots. A 100 nF100\ \text{nF} ceramic capacitor across the motor terminals (as toy makers fit for radio suppression) visibly reduces the spikes.

Hazards and safe setup. Low voltage only, supply current limit at the motor's rating. Clamp the motor; braking with fingers is only for a tiny motor, through a pad, never on a shaft with a gear or pulley. Scope ground clip on the supply negative only. Sparking brushed motors make ozone and carbon dust in long runs; don't run them near flammable vapour.

Pitfalls

  • Thinking armature reaction only "tilts" the field. With saturation, it also lowers the flux per pole.
  • Shifting the brushes the wrong way. Generator: with rotation; motor: against it. And only for one load.
  • Putting interpoles in shunt. Their MMF must follow IaI_a, so they are in series with the armature.
  • Ignoring commutation when overloading. The reactance voltage grows with both current and speed; DC machines have a commutation limit on current times speed, not only a thermal limit.

Practice

  1. A 6-pole wave-wound machine (a=2a = 2) has Z=540Z = 540 and Ia=120 AI_a = 120\ \text{A}. Find FaF_a per pole.
  2. Double the speed of the worked example. What happens to tct_c and ere_r?
  3. Why does a compensating winding reduce the risk of flashover?
Answer
  1. Fa=540⋅120/(2⋅2⋅6)=2700F_a = 540 \cdot 120/(2 \cdot 2 \cdot 6) = 2700 A-turns per pole.
  2. tct_c halves to 0.398 ms0.398\ \text{ms}, so ere_r doubles to 9.42 V9.42\ \text{V}; the interpole EMF is also proportional to speed, so a correctly designed interpole still cancels it.
  3. It cancels the armature MMF under the pole face, so the flux density no longer piles up at one tip and the voltage between adjacent segments stays near its average.

Test yourself

Along which axis does the armature MMF of a DC machine act?

  1. the field (pole) axis
  2. the brush axis, 90∘90^\circ electrical from the field axis
  3. it rotates with the armature
  4. it has no fixed axis

Why does armature reaction reduce the flux per pole?

  1. the armature MMF is in direct opposition to the field
  2. the strengthened pole tip saturates, so it gains less flux than the weakened tip loses
  3. the brushes short the field
  4. eddy currents in the poles

Interpole windings are connected…

  1. in parallel with the field
  2. in series with the armature
  3. across the brushes
  4. to a separate supply

The reactance voltage of a commutating coil is about Lc⋅2Ic/tcL_c \cdot 2I_c/t_c. Doubling the armature current and the speed multiplies it by…

  1. 1
  2. 2
  3. 4
  4. 8