Armature Reaction and Commutation
The EMF equation of the previous lesson assumed that the flux under each pole is set by the field winding alone. On load that is not true: the armature current is itself a winding with ampere-turns, and its magnetic field adds to the main field. This armature reaction distorts the flux under the poles, moves the magnetic neutral away from the brushes and, once the pole tips saturate, reduces the flux per pole. At the same time, every coil passing under a brush must reverse its current in well under a millisecond, against its own inductance. If the reversal is incomplete when the segment leaves the brush, the remaining energy goes into a spark. Brush wear, radio noise and, in bad cases, a flashover around the commutator follow. This lesson puts numbers on both effects and shows the three remedies: brush shift, interpoles and compensating windings.
The armature MMF
Each armature conductor carries , and the current direction changes at the brushes. The armature therefore acts like a winding whose axis lies along the brush axis, at electrical to the field axis. Its MMF grows linearly from one brush to the next and peaks at the brush axis with
Under a pole the armature MMF adds to the field MMF at one tip and subtracts at the other: it is cross-magnetising. Three consequences:
- Distortion and neutral shift. The point of zero flux density, the magnetic neutral axis, moves away from the geometric neutral, forwards (in the direction of rotation) in a generator and backwards in a motor. Coils at the brushes now have EMF in them while they are short-circuited.
- Demagnetisation through saturation. If the iron were linear, the extra flux at one tip would cancel the loss at the other. The strengthened tip saturates, so it gains less than the weak tip loses: the net flux per pole falls, and with it (generator voltage drops) or the motor speeds up (less flux, see DC Motors).
- High coil voltages under the strong tip. Coils there cut a high flux density, so the voltage between adjacent commutator segments rises locally; above roughly 30 to 40 V between segments, an arc between segments can grow into a flashover around the commutator.
Commutation
A coil under the brush is short-circuited while its current reverses from to . The commutation time is the time a segment takes to pass under the brush:
with brush width and commutator diameter . The coil's self- and mutual inductance opposes the reversal with the reactance voltage
If nothing cancels , the current lags behind ("under-commutation") and is still flowing when the segment leaves the brush: a spark at the trailing brush edge. Carbon brushes help because their contact resistance pushes the current towards linear reversal (resistance commutation), but in larger machines a voltage of the opposite sign must be induced in the commutating coil.
The remedies
| Remedy | How | Good for | Drawback |
|---|---|---|---|
| Brush shift | move the brushes to the new magnetic neutral (forward in a generator, back in a motor) | small machines at one load | correct for one load and one direction only; adds demagnetising MMF |
| Interpoles (commutating poles) | narrow poles on the geometric neutral, winding in series with the armature, so their MMF tracks | almost all DC machines above about 1 kW | more copper; set for one design |
| Compensating winding | conductors in the main pole faces, in series with the armature, opposing the armature MMF under the pole | large or fast-reversing machines (rolling mills) | expensive; also needs interpoles |
An interpole must first cancel the armature MMF at the brush axis, , and then add enough MMF to drive a commutating flux across its own gap, whose speed-dependent EMF cancels . Because both and are proportional to , a series winding keeps the balance at every load.
Worked example: armature reaction and interpole turns
Given: the 4-pole lap machine of the last lesson: , , , field A-turns per pole, pole arc 70 % of the pitch. Commutator at , brush width , commutating-coil inductance . The interpole gap needs A-turns to produce the commutating flux.
Find: , the MMF at the pole tips, the reactance voltage, the interpole turns, and the compensating-winding MMF.
Solve:
A compensating winding covering the pole face would carry A-turns per pole. It cancels the armature MMF only under the pole arc, so the interpoles still need the remaining A-turns plus the for their own gap: A-turns, turns (10 in practice) instead of 20.
Check: of a few volts is typical; a carbon brush's contact drop (about 1 V per brush) cannot absorb it alone, so the interpoles are needed. The tip MMFs differ by A-turns, which is the armature MMF swing across the pole arc.
In Python: flux per pole on load
The gap-and-teeth flux density saturates; model it as and average it over the pole arc.
import numpy as np
# MMF and gap flux density along one pole pitch of a 4-pole machine (x = 0..1 pole pitch)
Z, a, p = 480, 4, 4
Ff = 2000.0 # field ampere-turns per pole
x = np.linspace(0, 1, 2001)
under_pole = (x > 0.15) & (x < 0.85) # pole arc = 70 % of the pitch
Bs, F0 = 1.2, 1500.0 # saturating gap + teeth curve: B = Bs tanh(F/F0)
B = lambda F: Bs * np.tanh(F / F0)
flux0 = np.where(under_pole, B(Ff), 0).mean()
print(f"field MMF {Ff:.0f} A-turns per pole, no-load pole-face B = {B(Ff):.3f} T")
print(" Ia Fa B weak tip B strong tip flux / no-load flux")
for Ia in (25, 50, 75, 100):
Fa = Z * (Ia / a) / (2 * p) # armature ampere-turns per pole (peak, at the brush axis)
fa = Fa * (2 * x - 1) # triangular: -Fa at one brush axis, +Fa at the next
flux = np.where(under_pole, B(Ff + fa), 0).mean()
print(f"{Ia:4d} A {Fa:5.0f} {B(Ff - 0.7*Fa):.3f} T {B(Ff + 0.7*Fa):.3f} T {flux/flux0:.4f}")
# commutation: reactance voltage of the coil being reversed, at Ia = 50 A
D, n, wb, Lc, Ia = 0.20, 1200, 0.010, 0.15e-3, 50
v = np.pi * D * n / 60 # commutator surface speed
tc = wb / v # time a segment spends under the brush
Ic = Ia / a
print(f"surface speed {v:.2f} m/s, commutation time {tc*1e3:.3f} ms")
print(f"coil current {Ic:+.1f} A -> {-Ic:+.1f} A, reactance voltage L*2Ic/tc = {Lc*2*Ic/tc:.2f} V")field MMF 2000 A-turns per pole, no-load pole-face B = 1.044 T
Ia Fa B weak tip B strong tip flux / no-load flux
25 A 375 0.985 T 1.088 T 0.9975
50 A 750 0.905 T 1.120 T 0.9900
75 A 1125 0.802 T 1.143 T 0.9774
100 A 1500 0.672 T 1.160 T 0.9596
surface speed 12.57 m/s, commutation time 0.796 ms
coil current +12.5 A -> -12.5 A, reactance voltage L*2Ic/tc = 4.71 V
The weak tip loses at while the strong tip gains only ; the flux per pole falls by 1 % at rated current and by 4 % at twice rated. Small as it looks, a 4 % flux loss raises a motor's speed by about 4 % at the moment the load is heaviest, which can make a shunt motor unstable. A compensating winding removes the effect.
Guided lab: see commutation in a small motor
Hand calculation. For a toy motor with a commutator at and a brush, and ; a 3-segment commutator switches times per revolution, events per second.
Simulation. Run the Python cell with a smaller pole arc or a larger to see how quickly saturation turns distortion into flux loss.
What you would measure. Run a small brushed motor (rated at most ) from a current-limited bench supply through a shunt, with the scope across the shunt. Expect a current ripple at the commutation frequency ( in the example above, with speed) with sharp spikes at each switching edge; load the shaft lightly with your fingers on a felt pad (or a friction brake) and the spikes grow. In a dark room you can see blue sparking at the brushes through the end-cap slots. A ceramic capacitor across the motor terminals (as toy makers fit for radio suppression) visibly reduces the spikes.
Hazards and safe setup. Low voltage only, supply current limit at the motor's rating. Clamp the motor; braking with fingers is only for a tiny motor, through a pad, never on a shaft with a gear or pulley. Scope ground clip on the supply negative only. Sparking brushed motors make ozone and carbon dust in long runs; don't run them near flammable vapour.
Pitfalls
- Thinking armature reaction only "tilts" the field. With saturation, it also lowers the flux per pole.
- Shifting the brushes the wrong way. Generator: with rotation; motor: against it. And only for one load.
- Putting interpoles in shunt. Their MMF must follow , so they are in series with the armature.
- Ignoring commutation when overloading. The reactance voltage grows with both current and speed; DC machines have a commutation limit on current times speed, not only a thermal limit.
Practice
- A 6-pole wave-wound machine () has and . Find per pole.
- Double the speed of the worked example. What happens to and ?
- Why does a compensating winding reduce the risk of flashover?
Answer
- A-turns per pole.
- halves to , so doubles to ; the interpole EMF is also proportional to speed, so a correctly designed interpole still cancels it.
- It cancels the armature MMF under the pole face, so the flux density no longer piles up at one tip and the voltage between adjacent segments stays near its average.
Test yourself
Along which axis does the armature MMF of a DC machine act?
- the field (pole) axis
- the brush axis, electrical from the field axis
- it rotates with the armature
- it has no fixed axis
Why does armature reaction reduce the flux per pole?
- the armature MMF is in direct opposition to the field
- the strengthened pole tip saturates, so it gains less flux than the weakened tip loses
- the brushes short the field
- eddy currents in the poles
Interpole windings are connected…
- in parallel with the field
- in series with the armature
- across the brushes
- to a separate supply
The reactance voltage of a commutating coil is about . Doubling the armature current and the speed multiplies it by…
- 1
- 2
- 4
- 8