TExcelTAD
Home › Electrical Machines & Transformers › DC Motors: Characteristics and Start-Up

DC Motors: Characteristics and Start-Up

Connect a stationary DC motor straight to its rated voltage and, for the first few milliseconds, the only thing limiting the current is the armature resistance: a 220 V220\ \text{V} industrial motor would draw more than ten times its rated current, and a 12 V12\ \text{V} hobby motor draws its full stall current. As the rotor speeds up the back-EMF grows and the current falls. Where it settles depends on the load torque and on how the field is connected, and that gives each type its personality: the shunt motor holds its speed, the series motor has huge starting torque and runs away when unloaded. This lesson derives the speed–torque characteristics from two equations, sizes a starter, and simulates a start-up three ways: in Python, in the netlist lab and in ngspice.

Equivalent circuit and the speed equation

+V F, Rf If Ra +Ea = k w Ia IL load T, w_m V = Ea + Ia Ra, T = K_a Phi Ia

From V=Ea+IaRaV = E_a + I_a R_a, Ea=KaΦωmE_a = K_a\Phi\omega_m and T=KaΦIaT = K_a\Phi I_a:

ωm=V−IaRaKaΦ=VKaΦ−Ra(KaΦ)2 T\omega_m = \frac{V - I_a R_a}{K_a\Phi} = \frac{V}{K_a\Phi} - \frac{R_a}{(K_a\Phi)^2}\,T

With constant flux (separately excited, shunt on a fixed supply, permanent magnet) this is a straight line: a no-load speed V/KaΦV/K_a\Phi and a small droop proportional to torque. In a series motor the field carries IaI_a, so (below saturation) Φ∝Ia\Phi \propto I_a, T∝Ia2T \propto I_a^2 and

ωm≈Vc Ia−Ra+Rsc(T=c Ia2)\omega_m \approx \frac{V}{c\, I_a} - \frac{R_a + R_s}{c} \qquad (T = c\,I_a^2)

Speed falls steeply with torque and rises without limit as the load disappears: a series motor must never run unloaded or on a belt that can slip off. It suits traction and hoists, where starting torque matters most. Compound motors (a shunt field plus a cumulative series field) lie between the two.

Worked example: a shunt motor and its starter

Given: a 220 V220\ \text{V} shunt motor, Ra=0.4 ΩR_a = 0.4\ \Omega, rated armature current 40 A40\ \text{A} at 1500 rpm1500\ \text{rpm}; constant field.

Find: KaΦK_a\Phi, rated torque, no-load speed (at Ia=2 AI_a = 2\ \text{A}), the direct-on-line starting current, and a starter that limits the current to 80 A80\ \text{A}.

Solve:

KaΦ=220−40⋅0.4157.08 rad/s=1.2987 V s/rad,T=1.2987⋅40=51.95 N mn0=220−2⋅0.41.2987⋅602π=1612 rpmIstart=220 V0.4 Ω=550 A=13.75×ratedRtotal=220 V80 A=2.75 Ω ⇒ Rstarter=2.35 Ω\begin{aligned} K_a\Phi &= \frac{220 - 40 \cdot 0.4}{157.08\ \text{rad/s}} = 1.2987\ \text{V s/rad}, \qquad T = 1.2987 \cdot 40 = 51.95\ \text{N m} \\ n_0 &= \frac{220 - 2 \cdot 0.4}{1.2987} \cdot \frac{60}{2\pi} = 1612\ \text{rpm} \\ I_\text{start} &= \frac{220\ \text{V}}{0.4\ \Omega} = 550\ \text{A} = 13.75 \times \text{rated} \\ R_\text{total} &= \frac{220\ \text{V}}{80\ \text{A}} = 2.75\ \Omega \ \Rightarrow\ R_\text{starter} = 2.35\ \Omega \end{aligned}

Check: speed regulation (1612−1500)/1500=7.5 %(1612 - 1500)/1500 = 7.5\ \%, typical of a shunt motor. As the motor accelerates, EaE_a rises and the current falls; when it reaches 40 A40\ \text{A} (Ea=110 VE_a = 110\ \text{V}) the starter steps down so the current jumps back to 80 A80\ \text{A}. The code finds three steps. This is a mains-derived industrial motor: calculation only.

python · try it yourself
import numpy as np

# a 220 V shunt motor (calculation only): Ra = 0.4 ohm, rated Ia = 40 A at 1500 rpm
V, Ra, Ia_r, n_r = 220.0, 0.4, 40.0, 1500
kphi = (V - Ia_r * Ra) / (2 * np.pi * n_r / 60)          # V s/rad = N m/A
print(f"K_a*Phi = {kphi:.4f} V s/rad, rated torque = {kphi*Ia_r:.2f} N m")
for Ia in (2, 20, 40, 60):
    w = (V - Ia * Ra) / kphi
    print(f"  Ia = {Ia:2d} A: T = {kphi*Ia:6.2f} N m, n = {w*60/(2*np.pi):6.0f} rpm")

# direct-on-line start and a graded starter that keeps the current between 80 A and 40 A
print(f"direct start: Ia = V/Ra = {V/Ra:.0f} A = {V/Ra/Ia_r:.2f} x rated")
I_hi, I_lo, R, k = 80.0, 40.0, V / 80.0, 1
while R > Ra:
    print(f"  step {k}: total R = {R:.4f} ohm (starter {R-Ra:.4f} ohm), switch out at E = {V - I_lo*R:.1f} V")
    E = V - I_lo * R
    R, k = (V - E) / I_hi, k + 1
print(f"  last step: starter out, current jumps to {(V - E)/Ra:.2f} A")

# series motor (unsaturated): Phi proportional to I, so T = c I^2 and w = (V - I R)/(c I)
c, Rs = kphi / 40, 0.6                                    # same flux at 40 A; armature + series field
print("series motor:")
for I in (10, 20, 40, 60):
    w = (V - I * Rs) / (c * I)
    print(f"  I = {I:2d} A: T = {c*I*I:6.1f} N m, n = {w*60/(2*np.pi):6.0f} rpm")
K_a*Phi = 1.2987 V s/rad, rated torque = 51.95 N m
  Ia =  2 A: T =   2.60 N m, n =   1612 rpm
  Ia = 20 A: T =  25.97 N m, n =   1559 rpm
  Ia = 40 A: T =  51.95 N m, n =   1500 rpm
  Ia = 60 A: T =  77.92 N m, n =   1441 rpm
direct start: Ia = V/Ra = 550 A = 13.75 x rated
  step 1: total R = 2.7500 ohm (starter 2.3500 ohm), switch out at E = 110.0 V
  step 2: total R = 1.3750 ohm (starter 0.9750 ohm), switch out at E = 165.0 V
  step 3: total R = 0.6875 ohm (starter 0.2875 ohm), switch out at E = 192.5 V
  last step: starter out, current jumps to 68.75 A
series motor:
  I = 10 A: T =    3.2 N m, n =   6294 rpm
  I = 20 A: T =   13.0 N m, n =   3059 rpm
  I = 40 A: T =   51.9 N m, n =   1441 rpm
  I = 60 A: T =  116.9 N m, n =    902 rpm

Between 2020 and 60 A60\ \text{A} the shunt motor's speed changes by 8 %; the series motor's changes by a factor of 3.4, and at a quarter of rated current it would already exceed 6000 rpm6000\ \text{rpm}. Today a starter is usually a controlled converter that ramps the armature voltage instead of a resistor bank (Power Electronics & Motor Drives).

Start-up transient of a small motor

Two first-order equations, one electrical and one mechanical, describe a permanent-magnet motor with constant kk, inertia JJ, viscous friction BB and load torque TLT_L:

Ldidt=V−Ri−kωm,Jdωmdt=ki−Bωm−TLL\frac{di}{dt} = V - Ri - k\omega_m, \qquad J\frac{d\omega_m}{dt} = k i - B\omega_m - T_L

Their time constants are the electrical τe=L/R\tau_e = L/R and the mechanical τm=JR/k2\tau_m = JR/k^2; when τe≪τm\tau_e \ll \tau_m the speed rises almost like a first-order system with τm\tau_m. The same model, as a transfer function, is the plant of DC Motor Models in the control course.

python · try it yourself
import numpy as np
from scipy.integrate import solve_ivp

# small 12 V permanent-magnet motor: armature R, L; constant k; rotor inertia J; viscous friction B
V, R, L, k, J, B = 12.0, 2.0, 1e-3, 0.02, 2e-6, 1e-6

def motor(t, x, TL):
    i, w = x
    return [(V - R * i - k * w) / L,          # L di/dt = V - R i - k w
            (k * i - B * w - TL) / J]         # J dw/dt = k i - B w - T_load

print(f"tau_e = L/R = {L/R*1e3:.2f} ms, tau_m = J R / k^2 = {J*R/k**2*1e3:.2f} ms")
print(f"stall current V/R = {V/R:.1f} A, no-load speed = {V*k/(k*k + R*B):.1f} rad/s")
for TL in (0.0, 0.03):
    sol = solve_ivp(motor, (0, 0.06), [0.0, 0.0], args=(TL,), method="LSODA",
                    max_step=1e-5, rtol=1e-8, atol=1e-10)
    i, w = sol.y
    j = int(np.argmax(i))
    w_end = float(w[-1])
    t63 = float(sol.t[np.argmax(w >= 0.632 * w_end)])
    print(f"load {TL*1e3:4.0f} mN m: peak {i[j]:.2f} A at {sol.t[j]*1e3:.2f} ms, "
          f"63 % speed at {t63*1e3:.1f} ms, after 60 ms: {w_end:.1f} rad/s "
          f"({w_end*60/(2*np.pi):.0f} rpm), {float(i[-1]):.3f} A")
tau_e = L/R = 0.50 ms, tau_m = J R / k^2 = 10.00 ms
stall current V/R = 6.0 A, no-load speed = 597.0 rad/s
load    0 mN m: peak 5.34 A at 1.61 ms, 63 % speed at 9.9 ms, after 60 ms: 595.9 rad/s (5691 rpm), 0.041 A
load   30 mN m: peak 5.52 A at 1.76 ms, 63 % speed at 10.1 ms, after 60 ms: 446.9 rad/s (4268 rpm), 1.531 A

The current peaks at 5.34 A5.34\ \text{A}, close to the 6 A6\ \text{A} stall value, because the rotor has hardly moved in 1.6 ms1.6\ \text{ms}; it then decays with the speed rise, which reaches 63 % in one mechanical time constant, 10 ms10\ \text{ms}. With a 30 mN m30\ \text{mN m} load the motor settles near 447 rad/s447\ \text{rad/s} drawing 1.5 A1.5\ \text{A}.

Interactive: the motor as a circuit

The mechanical equation has the form of a capacitor equation, so the whole motor fits in a netlist: node w is the speed (read 1 V1\ \text{V} as 1 rad/s1\ \text{rad/s}), the capacitor CJ =2 μF= 2\ \mu\text{F} is the inertia J=2×10−6 kg m2J = 2 \times 10^{-6}\ \text{kg m}^2, the resistor RB =1 MΩ= 1\ \text{M}\Omega is 1/B1/B, the source EB makes the back-EMF kωmk\omega_m, GT injects the torque kik i as a current, and ITL draws the load torque. At t=1.6 mst = 1.6\ \text{ms} the lab shows 5.342 A5.342\ \text{A}; at 10 ms10\ \text{ms} the speed is 378.1 rad/s378.1\ \text{rad/s}; at 60 ms60\ \text{ms}, 595.9 rad/s595.9\ \text{rad/s} and 41.33 mA41.33\ \text{mA}, the same as the Python result.

02004006000204060t (ms)V0 A2.0 A4.0 AI (A)V(w)I(RA)at t = 60.00 msV(a)12.0 VV(b)11.9 VV(c)11.9 VV(w)596 VI(V1)-41.3 mAI(RA)41.3 mAI(LA)41.3 mAI(EB)41.3 mAI(GT)827 uAI(CJ)231 uAI(RB)596 uAI(ITL)0 A

Raise the load torque to 60 mN m60\ \text{mN m}: the speed settles much lower and the current stays near 3 A3\ \text{A}. Halve the supply voltage: the no-load speed halves but the shape of the start-up is unchanged, since τm\tau_m does not depend on VV.

Cross-check in ngspice

bash · try it yourself
cat > motor.cir <<'EOF'
* 12 V PM DC motor: electrical side and mechanical analogue (node w: 1 V = 1 rad/s)
V1 a 0 12
RA a b 2
LA b c 1m
EB c 0 w 0 0.02
GT 0 w a b 0.01
CJ w 0 2u
RB w 0 1meg
.control
tran 10u 60m uic
meas tran imax MIN i(V1)
meas tran t63 WHEN v(w)=377.3 RISE=1
meas tran wend FIND v(w) AT=60m
meas tran iend FIND i(V1) AT=60m
.endc
.end
EOF
ngspice -b motor.cir 2>&1 | grep -E '^(imax|t63|wend|iend)'
imax                =  -5.342094e+00 at=  1.612904e-03
t63                 =  9.964431e-03
wend                =  5.959279e+02
iend                =  -4.132993e-02

SPICE reports the source current as negative (it delivers power): the peak is 5.342 A5.342\ \text{A} at 1.61 ms1.61\ \text{ms}, 63 % of the final speed (377.3 rad/s377.3\ \text{rad/s}) at 9.96 ms9.96\ \text{ms}, and 595.9 rad/s595.9\ \text{rad/s} at 60 ms60\ \text{ms}: three independent solvers agree.

Guided lab: start a small motor

Hand calculation. Measure RR with the rotor held still (a low-current ohmmeter reading jumps with brush position, so take the median of several rotor positions), estimate kk from the no-load speed, and predict the stall current V/RV/R and τm\tau_m if the datasheet gives JJ.

Simulation. Put your RR, kk and supply voltage into the netlist lab or the Python cell.

What you would measure. Supply the motor at 6 V6\ \text{V} from a bench supply whose current limit is set above the expected peak (otherwise you measure the supply's limit), through a 0.1 Ω0.1\ \Omega shunt. Trigger a scope on the rising current: expect a fast rise to about 0.80.8 to 0.90.9 of V/RV/R in a millisecond or two, then a decay over a few tens of milliseconds to the no-load current, with commutator ripple on top. Peak values scatter by ±10 %\pm 10\ \% with rotor position.

Hazards and safe setup. Small motor, at most 24 V24\ \text{V}, supply current limit at no more than the motor's stall current; clamp the motor; nothing on the shaft that can fly off; keep fingers, hair and sleeves clear. Do not hold the motor stalled for more than a second or two: stall current heats the winding fast. When you switch off, the spinning motor keeps generating and the armature inductance kicks: a flyback diode across a switch-controlled motor is standard.

Pitfalls

  • Starting at full voltage without a limit. The first-instant current is V/RaV/R_a; industrial motors need a starter or a converter.
  • Running a series motor unloaded. It overspeeds; belts and clutches on series motors are forbidden for that reason.
  • Expecting more speed from more field. In a shunt motor more flux means lower speed (next lesson).
  • Confusing τm\tau_m with a fixed property. It depends on the load's inertia: a flywheel on the shaft multiplies it.

Practice

  1. The shunt motor of the worked example carries 50 A50\ \text{A}. Find the speed and torque.
  2. With the starter's first step (2.75 Ω2.75\ \Omega total), at what speed does the current fall to 40 A40\ \text{A}?
  3. Find τm\tau_m of the small motor if a load with J=6×10−6 kg m2J = 6 \times 10^{-6}\ \text{kg m}^2 is added.
Answer
  1. T=1.2987⋅50=64.9 N mT = 1.2987 \cdot 50 = 64.9\ \text{N m}; ωm=(220−20)/1.2987=154.0 rad/s=1471 rpm\omega_m = (220 - 20)/1.2987 = 154.0\ \text{rad/s} = 1471\ \text{rpm}.
  2. Ea=220−40⋅2.75=110 VE_a = 220 - 40 \cdot 2.75 = 110\ \text{V}, ωm=110/1.2987=84.7 rad/s=809 rpm\omega_m = 110/1.2987 = 84.7\ \text{rad/s} = 809\ \text{rpm}.
  3. J=8×10−6J = 8 \times 10^{-6}, τm=8×10−6⋅2/0.0004=40 ms\tau_m = 8 \times 10^{-6} \cdot 2/0.0004 = 40\ \text{ms}.

Test yourself

At the instant a stationary DC motor is connected to its supply, the current is limited by…

  1. the back-EMF
  2. the armature resistance (and any starter resistance)
  3. the field current
  4. the load torque

Why must a series DC motor not run without load?

  1. it stalls
  2. its field collapses and the speed rises dangerously
  3. it reverses
  4. it draws its starting current

The mechanical time constant of a PM motor is…

  1. L/RL/R
  2. JR/k2JR/k^2
  3. k/Jk/J
  4. RCRC

A shunt motor's speed at rated load is 1500 rpm and at no load 1612 rpm. Its speed regulation is about…

  1. 0.75 %
  2. 7.5 %
  3. 15 %
  4. 75 %