TExcelTAD
Home › Electrical Machines & Transformers › DC Machine Losses, Efficiency and Permanent-Magnet Motors

DC Machine Losses, Efficiency and Permanent-Magnet Motors

A motor that converts 86 % of its input into shaft power still turns 14 % into heat, and that heat, not the torque the magnetic circuit could produce, usually sets the rating. Knowing which losses are fixed and which grow with load tells you where a machine is most efficient, how hot it will run, and why a motor that is too big for its job wastes energy just as surely as one that is too small. This lesson sorts the losses of a DC machine, finds the condition for maximum efficiency, and then turns to the most common DC machine of all: the small permanent-magnet DC motor in toys, pumps, car seats and robots, whose whole behaviour follows from three numbers you can measure on the bench.

Where the power goes

input V IL Ea Ia = T w (converted) shaft output field V If Ia^2 Ra brush drop core friction, windage stray
Loss Depends on Typical size
Armature copper Ia2RaI_a^2 R_a (and series, interpole windings) load current squared the largest load-dependent loss
Brush contact ≈1 V\approx 1\ \text{V} per carbon brush, times IaI_a small, linear in current
Field copper VIfV I_f (shunt) constant on a fixed supply 1 to 5 % of rating
Core loss (hysteresis and eddy in the armature, Core Losses) flux and speed roughly constant at constant speed
Friction and windage speed roughly constant at constant speed
Stray load loss load (eddy currents from distorted flux, armature reaction) about 1 % of output when not measured

Group them: constant losses PcP_c (field, core, friction and windage, fixed at a given speed and flux) and variable losses Ia2RaI_a^2 R_a. Since η=Pout/Pin\eta = P_\text{out}/P_\text{in} and the output is roughly proportional to IaI_a, the loss per unit output is Pc/Ia+IaRaP_c/I_a + I_a R_a (times a constant), which is smallest when the two terms are equal:

η=ηmaxwhenIa2Ra≈Pc\eta = \eta_\text{max} \quad \text{when} \quad I_a^2 R_a \approx P_c

This "variable loss equals constant loss" rule holds for every machine and transformer (Regulation and Efficiency uses it for transformers). Designers place the maximum near the load at which the machine spends most of its time, usually 75 to 100 % of rating.

Worked example: efficiency of a shunt motor

Given: the 220 V220\ \text{V} shunt motor of DC Motors: Ra=0.4 ΩR_a = 0.4\ \Omega (brushes included), shunt field current If=1.0 AI_f = 1.0\ \text{A}, rotational losses (core, friction, windage) 400 W400\ \text{W} at about rated speed; rated Ia=40 AI_a = 40\ \text{A}.

Find: the efficiency at rated load and the armature current for maximum efficiency.

Solve:

Pc=220 V⋅1.0 A+400 W=620 WPin=220 V⋅(40+1) A=9020 WPcu=402⋅0.4=640 WPout=9020−620−640=7760 W,η=77609020=86.0 %Ia,ηmax⁡≈620/0.4=39.4 A\begin{aligned} P_c &= 220\ \text{V} \cdot 1.0\ \text{A} + 400\ \text{W} = 620\ \text{W} \\ P_\text{in} &= 220\ \text{V} \cdot (40 + 1)\ \text{A} = 9020\ \text{W} \\ P_\text{cu} &= 40^2 \cdot 0.4 = 640\ \text{W} \\ P_\text{out} &= 9020 - 620 - 640 = 7760\ \text{W}, \qquad \eta = \frac{7760}{9020} = 86.0\ \% \\ I_{a,\eta\max} &\approx \sqrt{620/0.4} = 39.4\ \text{A} \end{aligned}

Check: the converted power EaIa=(220−16) V⋅40 A=8160 WE_a I_a = (220 - 16)\ \text{V} \cdot 40\ \text{A} = 8160\ \text{W} minus the 400 W400\ \text{W} rotational loss gives the same 7760 W7760\ \text{W}. Counting the field current in the input as well moves the exact optimum to 38.4 A38.4\ \text{A}, but the efficiency curve is so flat there that the difference is below 0.01 %0.01\ \%. Calculation only: this is a mains-derived motor.

Permanent-magnet DC motors

A PMDC motor replaces the field winding with magnets (ferrite in cheap motors, NdFeB in compact high-performance ones), so there is no field loss and the flux is fixed: it is a separately excited motor with KaΦ=kK_a\Phi = k. Everything follows from the armature resistance RR, the constant kk and the friction, which you can find from the no-load current I0I_0:

I=T+Tfk,ωm=V−IRk,η=TωmVII = \frac{T + T_f}{k}, \qquad \omega_m = \frac{V - IR}{k}, \qquad \eta = \frac{T\omega_m}{VI}

Datasheets list these as terminal resistance, torque constant (N·m/A), speed constant (rpm/V, the inverse of kk), no-load speed and current, stall torque and stall current, and the speed–torque gradient. Two operating points are worth remembering:

  • Maximum output power at half the stall torque (half the no-load speed), with efficiency below 50 %: fine for a few seconds of peak demand, not for continuous use.
  • Maximum efficiency at a much lighter load: with constant friction it occurs at I=I0IstallI = \sqrt{I_0 I_\text{stall}}.

Magnets bring limits of their own: a large current (a stall at high voltage, or plugging) can partly demagnetise ferrite magnets, especially when cold, and NdFeB loses flux when hot. Continuous current is set by winding temperature; the brushes and commutator wear, which is why brushless motors (BLDC and PMSM) took over long-life applications.

In Python: two efficiency curves

python · try it yourself
import numpy as np

# 1) the 220 V shunt motor: where does the input go? (calculation only)
V, Ra, If, Prot = 220.0, 0.4, 1.0, 400.0          # field current 1 A; core + friction + windage 400 W
Pconst = V * If + Prot
print(f"constant losses: field {V*If:.0f} W + rotational {Prot:.0f} W = {Pconst:.0f} W")
print(f"maximum efficiency where Ia^2 Ra = constant losses: Ia = {np.sqrt(Pconst/Ra):.2f} A")
print("  Ia     input    copper   output   efficiency")
for Ia in (10, 20, 30, np.sqrt(Pconst / Ra), 40, 50):
    Pin = V * (Ia + If)
    Pcu = Ia**2 * Ra
    Pout = Pin - Pconst - Pcu
    print(f"{Ia:5.1f} A {Pin:7.0f} W {Pcu:6.0f} W {Pout:7.0f} W   {Pout/Pin*100:5.2f} %")

# 2) a 12 V permanent-magnet motor from three measurements: R, k, no-load current
Vs, R, k, I0 = 12.0, 2.0, 0.02, 0.1
w0 = (Vs - I0 * R) / k                             # no-load speed
B = k * I0 / w0                                    # viscous friction that needs I0 at w0
Tstall = k * Vs / R
print(f"\nPM motor: no-load {w0:.0f} rad/s, B = {B:.3e} N m s, stall torque {Tstall*1e3:.0f} mN m")
T = np.linspace(0, Tstall, 120001)                 # load torque on the shaft
w = (k * Vs / R - T) / (k * k / R + B)             # steady state of both motor equations
I = (Vs - k * w) / R
eta = T * w / (Vs * I)
j, m = int(np.argmax(eta)), int(np.argmax(T * w))
print(f"max efficiency {eta[j]*100:.1f} % at T = {T[j]*1e3:.1f} mN m, I = {I[j]:.3f} A, {w[j]*60/(2*np.pi):.0f} rpm")
print(f"max power {T[m]*w[m]:.2f} W at T = {T[m]*1e3:.1f} mN m, efficiency there {eta[m]*100:.1f} %")
print(f"rule of thumb for constant friction: I at max efficiency = sqrt(I0 * Istall) = {np.sqrt(I0*Vs/R):.3f} A")
constant losses: field 220 W + rotational 400 W = 620 W
maximum efficiency where Ia^2 Ra = constant losses: Ia = 39.37 A
  Ia     input    copper   output   efficiency
 10.0 A    2420 W     40 W    1760 W   72.73 %
 20.0 A    4620 W    160 W    3840 W   83.12 %
 30.0 A    6820 W    360 W    5840 W   85.63 %
 39.4 A    8881 W    620 W    7641 W   86.04 %
 40.0 A    9020 W    640 W    7760 W   86.03 %
 50.0 A   11220 W   1000 W    9600 W   85.56 %

PM motor: no-load 590 rad/s, B = 3.390e-06 N m s, stall torque 120 mN m
max efficiency 77.1 % at T = 13.7 mN m, I = 0.775 A, 4990 rpm
max power 17.70 W at T = 60.0 mN m, efficiency there 48.4 %
rule of thumb for constant friction: I at max efficiency = sqrt(I0 * Istall) = 0.775 A

The big motor's efficiency is within one point of its maximum from 3030 to 50 A50\ \text{A} but drops to 73 % at a quarter load, where the constant losses dominate: an oversized motor wastes energy. The small motor peaks at 77 % at about a ninth of its stall torque, and delivers its maximum 17.7 W17.7\ \text{W} at half stall torque with less than 50 % efficiency.

Interactive: the PM motor's speed–torque line

The motor in the netlist lab (steady state: the inductor is a short, the inertia drops out) has RB =295 kΩ= 295\ \text{k}\Omega, i.e. B=3.39×10−6 N m sB = 3.39 \times 10^{-6}\ \text{N m s}. At zero load the lab shows 590.0 rad/s590.0\ \text{rad/s} and 100.0 mA100.0\ \text{mA} (the no-load current); at 60 mN m60\ \text{mN m} it shows 295.0 rad/s295.0\ \text{rad/s} and 3.050 A3.050\ \text{A}, so Pout=0.060⋅295=17.7 WP_\text{out} = 0.060 \cdot 295 = 17.7\ \text{W} from 12⋅3.05=36.6 W12 \cdot 3.05 = 36.6\ \text{W} in: 48.4 %.

node voltages (to ground 0)a12.00 Vb11.80 Vc11.80 Vw590.0 VnetlistV1 a 0 12RA a b 2LA b c 1mEB c 0 w 0 0.02GT 0 w a b 0.01RB w 0 295kITL w 0 0element currents (node 1 to node 2 through it)V1a>0-100 mARAa>b100 mALAb>c100 mAEBc>0100 mAGT0>w2.00 mARBw>02.00 mAITLw>00 A

Sweep the load torque: speed falls linearly, current rises linearly, and at 120 mN m120\ \text{mN m} (stall) the speed is nearly zero and the current 6 A6\ \text{A}.

Guided lab: characterise a PM motor

Hand calculation. From RR, kk and I0I_0 predict the efficiency curve with the Python cell, and the current at maximum efficiency I0Istall\sqrt{I_0 I_\text{stall}}.

Simulation. The netlist lab with your values (RA, the EB gain kk, the GT gain k/Rk/R, RB =ω0/(kI0)= \omega_0/(kI_0)).

What you would measure.

  1. RR: hold the rotor (clamped, not by hand) and pass 0.20.2 to 0.5 A0.5\ \text{A} from the current-limited supply; R=V/IR = V/I at several rotor positions (four-wire if RR is below 1 Ω1\ \Omega; Four-Wire Resistance). Expect ±10 %\pm 10\ \% scatter with brush position.
  2. kk: spin it from a second motor and measure the open-circuit voltage and speed (DC Machines: Construction), ±2 %\pm 2\ \%.
  3. I0I_0 and ω0\omega_0 at rated voltage, no load: a few percent of the stall current.
  4. Load it with a second motor working as a generator into resistors, or a small friction brake on a pulley with a spring balance, and compare the measured ωm\omega_m, II and η\eta with the prediction. Expect agreement within about 10 %; friction rises with load because of brush and bearing forces.

Hazards and safe setup. At most 24 V24\ \text{V} with a current limit; never hold a stalled motor at full voltage for more than a second or two (stall current heats the winding fast and can demagnetise ferrite magnets). Clamp everything; keep fingers, hair and sleeves away from pulleys and couplings; safety glasses. A small motor running fast stores enough energy in a flywheel to cut skin.

Pitfalls

  • Rating a motor at its maximum-power point. That is a short-time peak; continuous rating is limited by heat, usually well below half the stall torque.
  • Running a big motor at light load "for margin". Constant losses make light-load efficiency poor.
  • Ignoring brush drop at low voltage. In a 6 V6\ \text{V} motor, 2 V2\ \text{V} of brush drop would be a third of the supply; low-voltage motors use metal brushes with a much smaller drop.
  • Assuming ηmax\eta_\text{max} exactly where Ia2Ra=PcI_a^2R_a = P_c. It is a very good approximation; the exact optimum depends on what you count in the input.

Practice

  1. At what armature current is the worked-example motor's copper loss equal to its constant loss if the field current is 0.8 A0.8\ \text{A}?
  2. A PM motor has I0=0.05 AI_0 = 0.05\ \text{A} and stall current 8 A8\ \text{A}. Estimate the current at maximum efficiency.
  3. The small motor runs at 30 mN m30\ \text{mN m}. Use the formulas to estimate its speed and current (viscous friction as in the code).
Answer
  1. Pc=220⋅0.8+400=576 WP_c = 220 \cdot 0.8 + 400 = 576\ \text{W}; Ia=576/0.4=37.9 AI_a = \sqrt{576/0.4} = 37.9\ \text{A}.
  2. 0.05⋅8=0.632 A\sqrt{0.05 \cdot 8} = 0.632\ \text{A}.
  3. ωm=(0.12−0.03)/(0.0002+3.39×10−6)=442.5 rad/s\omega_m = (0.12 - 0.03)/(0.0002 + 3.39 \times 10^{-6}) = 442.5\ \text{rad/s} (4226 rpm); I=(12−0.02⋅442.5)/2=1.575 AI = (12 - 0.02 \cdot 442.5)/2 = 1.575\ \text{A}.

Test yourself

Maximum efficiency of a DC machine (and of a transformer) occurs approximately when…

  1. output is at rating
  2. variable copper losses equal constant losses
  3. the field current is zero
  4. core loss is zero

A PM motor gives its maximum mechanical power at…

  1. no load
  2. about half the stall torque
  3. stall
  4. maximum efficiency

Which loss does a permanent-magnet DC motor not have?

  1. armature copper loss
  2. brush contact loss
  3. field copper loss
  4. friction

A 220 V motor has constant losses of 620 W and Ra=0.4 ΩR_a = 0.4\ \Omega. At what armature current is the efficiency (nearly) highest?

  1. about 15.5 A
  2. about 39.4 A
  3. about 55 A
  4. at rated current, whatever it is