TExcelTAD
Home › Electrical Machines & Transformers › B–H Curves, Saturation and Magnetising Current

B–H Curves, Saturation and Magnetising Current

A transformer that hums quietly on its rated 230 V230\ \text{V} draws a magnetising current of a few tens of milliamperes. Feed it 10 %10\ \% more voltage and that current roughly doubles; 20 %20\ \% more and it rises more than twentyfold, the core heats, the hum turns into a growl and the current waveform becomes a series of sharp spikes. Nothing in a linear inductor model predicts this. The cause is the B–H curve of the steel, which this lesson turns into numbers you can design with. It builds on Magnetic Materials, Permeability and Hysteresis and Magnetic Circuits, which you should know: here the focus is what saturation does to a machine.

Safety: this lesson's transformer is a 230 V230\ \text{V} mains design and is studied by calculation and simulation only. The hands-on part uses a self-wound toroid driven at a few volts from a signal generator.

The steels machines are made of

Machines and transformers use electrical steel: iron with about 3 % silicon (which raises resistivity and cuts eddy currents), rolled into sheets 0.180.18 to 0.65 mm0.65\ \text{mm} thick and insulated on both faces.

  • Grain-oriented (GO) steel has its crystals lined up along the rolling direction. Along that direction it reaches 1.7 T1.7\ \text{T} with only a few tens of A/m; across it, it is much worse. Transformer cores, where the flux runs along the strips, use GO steel at a peak of about 1.51.5 to 1.75 T1.75\ \text{T}.
  • Non-oriented (NO) steel is roughly the same in every direction in the sheet, because in a rotating machine the flux turns through every direction in the teeth and yoke. It needs a few hundred A/m at 1.5 T1.5\ \text{T}, so motor cores work lower, and the air gap needs far more MMF than the iron anyway.

The numbers above are typical of the classes; a design uses the curves of the actual grade from its datasheet.

Voltage sets the flux

HB knee steep, then saturated t B(t) i(t): peaked

Faraday's law ties the applied voltage to the flux. Ignoring the small winding resistance, v=N dΦ/dtv = N\,d\Phi/dt, so a sinusoidal voltage forces a sinusoidal flux, whatever the current has to do to make it. With Φ=Φmsin⁡ωt\Phi = \Phi_m \sin\omega t the rms voltage is

V=ωNΦm2=2π2 fNΦm=4.44 fNABmV = \frac{\omega N \Phi_m}{\sqrt{2}} = \frac{2\pi}{\sqrt{2}}\, f N \Phi_m = 4.44\, f N A B_m

This EMF equation of the transformer is the first line of every core design. It also says that the peak flux density depends on the ratio V/fV/f: a 60 Hz60\ \text{Hz} transformer on a 50 Hz50\ \text{Hz} supply runs at 20 %20\ \% more flux, and a motor drive that lowers the frequency must lower the voltage with it (Starting Methods and Speed Control).

The current is then whatever the B–H curve demands: at each instant H(t)=H(B(t))H(t) = H(B(t)) and i(t)=H(t) ℓc/Ni(t) = H(t)\,\ell_c/N for a core of mean path ℓc\ell_c (plus the MMF of any joints or gap). Where the curve is steep, ii is small and nearly proportional to BB; each time BB passes the knee, HH shoots up and the current spikes. A sinusoidal flux in a saturating core needs a peaked magnetising current rich in odd harmonics, mostly the third. In three-phase transformers those third harmonics need a path (a delta winding provides one), a topic in Three-Phase Transformers and Vector Groups.

Worked example: turns for a 1.5 kVA core

Given: a single-phase core with a net steel cross-section A=30 cm2A = 30\ \text{cm}^2, mean path ℓc=0.60 m\ell_c = 0.60\ \text{m}, a 230 V230\ \text{V}, 50 Hz50\ \text{Hz} primary, design peak Bm=1.6 TB_m = 1.6\ \text{T}, grain-oriented steel needing H=26 A/mH = 26\ \text{A/m} at 1.6 T1.6\ \text{T}.

Find: the primary turns, the peak magnetising current, and the peak flux density on 60 Hz60\ \text{Hz} and at 253 V253\ \text{V}.

Solve:

N=V4.44 fABm=230 V4.44⋅50 Hz⋅30×10−4 m2⋅1.6 T=215.8→216 turnsipk=HℓcN=26 A/m⋅0.60 m216=72 mABm(60 Hz)=1.6 T⋅5060=1.33 T,Bm(253 V)=1.6 T⋅1.1=1.76 T\begin{aligned} N &= \frac{V}{4.44\, f A B_m} = \frac{230\ \text{V}}{4.44 \cdot 50\ \text{Hz} \cdot 30 \times 10^{-4}\ \text{m}^2 \cdot 1.6\ \text{T}} = 215.8 \to 216\ \text{turns} \\ i_\text{pk} &= \frac{H \ell_c}{N} = \frac{26\ \text{A/m} \cdot 0.60\ \text{m}}{216} = 72\ \text{mA} \\ B_m(60\ \text{Hz}) &= 1.6\ \text{T} \cdot \tfrac{50}{60} = 1.33\ \text{T}, \qquad B_m(253\ \text{V}) = 1.6\ \text{T} \cdot 1.1 = 1.76\ \text{T} \end{aligned}

Check: rated current is 1500 VA/230 V=6.5 A1500\ \text{VA}/230\ \text{V} = 6.5\ \text{A}, so the magnetising current is about 1 % of it, the right order for a GO-steel transformer (real cores with joints between the laminations need two or three times more). Units: $\text{V}/(\text{Hz} \cdot \text{m}^2 \cdot \text{T}) = \text{V}/(\text{V}) = $ turns, since 1 T⋅m2/s=1 V1\ \text{T} \cdot \text{m}^2/\text{s} = 1\ \text{V}.

In Python: the magnetising current from the curve

The program interpolates an illustrative GO-steel curve (a typical shape, not a datasheet), applies a sinusoidal flux at four voltages and reads off the current, then takes its harmonics with an FFT.

python · try it yourself
import numpy as np
from scipy.interpolate import PchipInterpolator
# illustrative B-H curve of a grain-oriented steel along the rolling direction (typical shape, not a datasheet)
B_tab = np.array([0, 0.5, 1.0, 1.3, 1.5, 1.6, 1.7, 1.8, 1.85, 1.9, 1.95, 2.0])
H_tab = np.array([0, 6, 11, 15, 20, 26, 40, 120, 300, 900, 2500, 6000])
H_of_B = PchipInterpolator(B_tab, H_tab)
H_of_Bs = lambda B: np.sign(B) * H_of_B(np.abs(B))

V, f, N, A, lc = 230.0, 50.0, 216, 30e-4, 0.60     # rms volts, Hz, turns, net core area m^2, mean path m
Bpk = np.sqrt(2) * V / (2 * np.pi * f * N * A)
print(f"peak flux density at {V:.0f} V: {Bpk:.3f} T")
t = np.arange(2000) / (2000 * f)                     # one period, 2000 samples
for scale in (0.9, 1.0, 1.1, 1.2):
    B = scale * Bpk * np.sin(2 * np.pi * f * t)
    i = H_of_Bs(B) * lc / N                          # magnetising current, A
    c = np.abs(np.fft.rfft(i)) / len(t) * np.sqrt(2) # rms of each harmonic
    irms = np.sqrt(np.mean(i**2))
    print(f"{scale*V:5.1f} V, Bpk {scale*Bpk:.2f} T: i peak {i.max()*1e3:7.1f} mA, rms {irms*1e3:6.1f} mA, "
          f"3rd {c[3]/c[1]*100:4.1f} %, 5th {c[5]/c[1]*100:4.1f} %")
peak flux density at 230 V: 1.598 T
207.0 V, Bpk 1.44 T: i peak    50.0 mA, rms   33.2 mA, 3rd  3.1 %, 5th  3.4 %
230.0 V, Bpk 1.60 T: i peak    71.7 mA, rms   41.8 mA, 3rd 11.3 %, 5th  7.5 %
253.0 V, Bpk 1.76 T: i peak   199.1 mA, rms   79.1 mA, 3rd 37.0 %, 5th 25.4 %
276.0 V, Bpk 1.92 T: i peak  3612.4 mA, rms 1074.4 mA, 3rd 84.2 %, 5th 68.8 %

Ten percent more voltage almost doubles the rms magnetising current and raises its third harmonic from 11 % to 37 % of the fundamental; twenty percent more multiplies the rms current by 26 and turns it into spikes more than three times its rms value. That is why transformers are designed with margin below the knee, why the equivalent circuit's magnetising reactance XmX_m is only a small-signal value at rated voltage, and why switching a transformer on can draw a huge inrush current (Parallel Operation and Inrush Current).

Hysteresis adds an in-phase part

The real B–H path is a loop, not a single curve. Going up, HH is larger than coming down at the same BB. The current waveform becomes asymmetric within each half-cycle, and its fundamental gains a component in phase with the voltage. That component carries real power, the hysteresis loss; with eddy currents it makes up the core loss of the next lesson (Hysteresis and Eddy-Current Losses). The equivalent circuit splits the no-load current accordingly: a magnetising part ImI_m through XmX_m, lagging the voltage by 90∘90^\circ, and a core-loss part IcI_c through RcR_c, in phase.

Guided lab: watch a toroid saturate

Hand calculation. Wind N=20N = 20 turns of enamelled wire on a ferrite toroid with cross-section AeA_e (datasheet, about 0.5 cm20.5\ \text{cm}^2 for a 25 mm25\ \text{mm} ring). A MnZn power ferrite saturates at about 0.40.4 to 0.5 T0.5\ \text{T} near room temperature (less when hot), and its current starts to peak earlier, around 0.35 T0.35\ \text{T}. The voltage that reaches that flux at 2 kHz2\ \text{kHz} is V=4.44 fNAeBm=4.44⋅2000⋅20⋅5×10−5⋅0.35=3.1 VV = 4.44\, f N A_e B_m = 4.44 \cdot 2000 \cdot 20 \cdot 5 \times 10^{-5} \cdot 0.35 = 3.1\ \text{V} rms.

Simulation. Replace the program's curve by the ferrite's datasheet B–H points and ℓc\ell_c, NN, AA, ff by your toroid's, and predict the current waveform at 11, 22, 33 and 3.5 V3.5\ \text{V}.

What you would measure. Drive the winding from a function generator through a small audio power amplifier, with a 1 Ω1\ \Omega current-sense resistor in series, and view the voltage across the winding and across the resistor on a two-channel oscilloscope (both channels referenced to the common ground at the resistor end). Raise the drive from 1 V1\ \text{V} rms: the current looks like a slightly distorted sine at first, then grows sharp peaks near 3 V3\ \text{V}. Expect the onset within about ±15 %\pm 15\ \% of the hand estimate: AeA_e, the ferrite grade's BsatB_\text{sat} and its temperature dependence all spread. The oscilloscope's FFT mode shows the third harmonic rising (Oscilloscope Triggering and FFT).

Hazards and safe setup. Signal-generator and audio-amplifier levels only, a few volts, never a mains transformer and never a mains winding driven backwards (a 12 V12\ \text{V} winding of a mains transformer driven at 12 V12\ \text{V} produces mains voltage on the other winding). Keep each saturated measurement short: the amplifier sees spikes of current, and the ferrite heats, which lowers BsatB_\text{sat} further.

Pitfalls

  • Treating XmX_m as a constant. It falls sharply above rated voltage; the equivalent circuit is only valid near its test voltage.
  • Ignoring V/fV/f. Flux scales with V/fV/f, not with VV alone.
  • Expecting a sinusoidal current. With a sinusoidal voltage it is the flux that is sinusoidal; the magnetising current is peaked.
  • Using a motor-steel curve for a transformer (or the reverse): GO and NO steels differ by an order of magnitude in HH at the same BB.

Practice

  1. A 400 V400\ \text{V}, 50 Hz50\ \text{Hz} winding on a core of A=120 cm2A = 120\ \text{cm}^2 is to run at 1.7 T1.7\ \text{T} peak. How many turns?
  2. The same transformer is moved to a 60 Hz60\ \text{Hz}, 460 V460\ \text{V} supply. What is the new peak flux density?
  3. Why does a delta winding help a three-phase transformer whose core saturates slightly?
Answer
  1. N=400/(4.44⋅50⋅0.012⋅1.7)=88.3N = 400/(4.44 \cdot 50 \cdot 0.012 \cdot 1.7) = 88.3, so 8989 turns (rounding up lowers BmB_m slightly).
  2. Bm∝V/fB_m \propto V/f: 1.7⋅(460/60)/(400/50)=1.7⋅7.667/8=1.63 T1.7 \cdot (460/60)/(400/50) = 1.7 \cdot 7.667/8 = 1.63\ \text{T}.
  3. The magnetising current needs a third-harmonic component to keep the flux sinusoidal. Third harmonics are in phase in all three phases, so they can circulate around a delta but not flow in a three-wire star; without that path the flux and the phase voltages distort.

Test yourself

A transformer winding is fed with a sinusoidal voltage. Which quantity is (almost) sinusoidal?

  1. the magnetising current
  2. the core flux
  3. the field intensity HH
  4. the core loss

The rms EMF of a winding with NN turns at frequency ff and peak flux Φm\Phi_m is…

  1. 2πfNΦm2\pi f N \Phi_m
  2. 4.44fNΦm4.44 f N \Phi_m
  3. fNΦm/2f N \Phi_m/\sqrt{2}
  4. NΦm/fN\Phi_m/f

A 60 Hz transformer is connected to a 50 Hz supply at the same voltage. Its peak flux density…

  1. falls by 17 %
  2. stays the same
  3. rises by 20 %
  4. rises by 44 %

The magnetising current of a saturating core contains mainly which extra harmonic?

  1. 2nd
  2. 3rd
  3. 4th
  4. only DC