Cooling, Insulation Classes, Testing and Maintenance

A motor rarely fails because its magnetic circuit wears out. It fails because a bearing runs dry, because dirt blocks its cooling fins, or because years of heat have made the varnish on its windings brittle until two turns touch. The thermal design ties together everything in the previous lesson: the rating is the load at which the losses heat the winding exactly to the temperature its insulation can stand for a normal life. This lesson covers how machines are cooled and protected (the IC and IP codes), the insulation thermal classes and the rule that every 10 K costs half the life, how temperature rise is measured, which tests a machine gets in the factory and in service, and what maintenance and condition monitoring look for.

Cooling and enclosure codes

Losses become heat in the windings and the core, flow by conduction to the frame and are carried away by air (or water). The IC code (IEC 60034-6; edition 1991, as of 2026) describes the cooling arrangement:

Code Meaning Typical machine
IC 411 totally enclosed, fan on its own shaft blows over a finned frame (TEFC) the standard low-voltage induction motor
IC 416 as IC 411 but with a separately powered fan motors on variable-speed drives that run slow at full torque
IC 01 open machine, internal fan draws ambient air through older drip-proof motors, large generators in clean rooms
IC 81W (and similar) internal air cooled by an air-to-water heat exchanger large machines

The IP code (IEC 60034-5 for rotating machines, based on IEC 60529) gives protection against solids (first digit) and water (second): IP55 (dust-protected, water jets) is common for industrial motors, IP23 for open machines indoors, IP66 or IP67 for wash-down areas.

Insulation thermal classes

Winding insulation (enamel on the wire, slot liners, impregnating resin) ages chemically with temperature. IEC 60085 (edition 2007, as of 2026) assigns thermal classes by the temperature the insulation system can stand for its intended life:

Class A E B F H N R
Temperature 105 ∘C105\,^\circ\text{C} 120 ∘C120\,^\circ\text{C} 130 ∘C130\,^\circ\text{C} 155 ∘C155\,^\circ\text{C} 180 ∘C180\,^\circ\text{C} 200 ∘C200\,^\circ\text{C} 220 ∘C220\,^\circ\text{C}

IEC 60034-1 then limits the temperature rise of the winding, measured by resistance, above a 40 ∘C40\,^\circ\text{C} coolant: for most medium machines about 80 K80\ \text{K} for class B, 105 K105\ \text{K} for class F and 125 K125\ \text{K} for class H (the margin to the class temperature covers the hot spot inside the winding). A common practice is "class F insulation, class B rise": the motor is built with class F materials but designed to rise only 80 K80\ \text{K}, which leaves roughly 25 K of margin.

The ageing follows an Arrhenius law. A useful engineering approximation (Montsinger's rule) is the 10 K rule: every 10 K above the rated temperature halves the insulation life, and every 10 K below doubles it:

LLrated≈2(Tclass−Thot spot)/10 K\frac{L}{L_\text{rated}} \approx 2^{(T_\text{class} - T_\text{hot spot})/10\ \text{K}}

Measuring the temperature rise

The winding's average temperature is found from its resistance, since copper's resistance is proportional to 234.5+θ234.5 + \theta (in ∘^\circC):

θ2=R2R1 (234.5+θ1)−234.5,Δθ=θ2−θamb\theta_2 = \frac{R_2}{R_1}\,(234.5 + \theta_1) - 234.5, \qquad \Delta\theta = \theta_2 - \theta_\text{amb}

R1R_1 is measured cold at a known temperature θ1\theta_1, R2R_2 immediately after a heat run at rated load (extrapolated back to the moment of switch-off, since the winding cools while you measure). For aluminium use 228 instead of 234.5.

Worked example: a heat run

Given: a motor's stator winding measures R1=0.800 ΩR_1 = 0.800\ \Omega at 20 ∘C20\,^\circ\text{C} before the test; after a heat run at rated load, R2=1.090 ΩR_2 = 1.090\ \Omega with the coolant (ambient) at 25 ∘C25\,^\circ\text{C}. The motor is marked "insulation class F".

Find: the winding temperature and rise; whether it meets class B and class F rise limits; the life factor compared with running at the class temperature, assuming the hot spot is 10 K10\ \text{K} above the average.

Solve:

θ2=1.0900.800 (234.5+20) ∘C−234.5=1.3625⋅254.5−234.5=112.3 ∘CΔθ=112.3−25=87.3 K  (>80 K class B, <105 K class F)LLrated≈2(155−122)/10=23.3≈9.7\begin{aligned} \theta_2 &= \frac{1.090}{0.800}\,(234.5 + 20)\ ^\circ\text{C} - 234.5 = 1.3625 \cdot 254.5 - 234.5 = 112.3\ ^\circ\text{C} \\ \Delta\theta &= 112.3 - 25 = 87.3\ \text{K}\ \ (> 80\ \text{K class B},\ < 105\ \text{K class F}) \\ \frac{L}{L_\text{rated}} &\approx 2^{(155 - 122)/10} = 2^{3.3} \approx 9.7 \end{aligned}

Check: a 36 % resistance increase corresponds to about 92 K92\ \text{K} of warming over the cold reading, which is what copper does (0.39 %0.39\ \% per K at 20 ∘C20\,^\circ\text{C}). The machine is acceptable as a class F motor with a class F rise, but not as "class F, rise B": a buyer who specified the latter would reject it. The heat run itself is done on mains-fed machines by a test laboratory: calculation only in this course.

In Python: rise, life and insulation resistance

python · try it yourself
import numpy as np

# 1) winding temperature by the resistance method (copper: 234.5 + theta is proportional to R)
R1, th1, R2, amb = 0.800, 20.0, 1.090, 25.0           # cold ohm at 20 C, hot ohm, ambient C at the end
th2 = R2 / R1 * (234.5 + th1) - 234.5
print(f"hot winding {th2:.1f} C, rise {th2 - amb:.1f} K")
for cls, limit in (("B", 80), ("F", 105), ("H", 125)):
    print(f"  rise limit class {cls} ({limit} K): {'ok' if th2 - amb <= limit else 'exceeded'}")

# 2) insulation life with the 10 K rule (life halves for every 10 K hotter)
hot_spot_margin = 10.0                                # K allowed between average and hot spot (assumed)
for cls, Tc in (("B", 130), ("F", 155), ("H", 180)):
    Thot = th2 + hot_spot_margin
    print(f"class {cls} ({Tc} C): hot spot about {Thot:.0f} C -> relative life x {2 ** ((Tc - Thot) / 10):6.1f}")

# 3) polarisation index from insulation-resistance readings (taken by a trained tester at 500 V DC)
readings = {"motor A": (850e6, 2.6e9), "motor B": (120e6, 150e6)}   # ohm after 1 min and 10 min
for name, (r1, r10) in readings.items():
    pi = r10 / r1
    print(f"{name}: IR(1 min) {r1/1e6:6.0f} Mohm, IR(10 min) {r10/1e6:6.0f} Mohm, PI = {pi:.2f} "
          f"-> {'acceptable' if pi >= 2.0 else 'investigate: moisture or contamination'}")
hot winding 112.3 C, rise 87.3 K
  rise limit class B (80 K): exceeded
  rise limit class F (105 K): ok
  rise limit class H (125 K): ok
class B (130 C): hot spot about 122 C -> relative life x    1.7
class F (155 C): hot spot about 122 C -> relative life x    9.7
class H (180 C): hot spot about 122 C -> relative life x   54.7
motor A: IR(1 min)    850 Mohm, IR(10 min)   2600 Mohm, PI = 3.06 -> acceptable
motor B: IR(1 min)    120 Mohm, IR(10 min)    150 Mohm, PI = 1.25 -> investigate: moisture or contamination

The same winding would last about ten times its rated life on class F insulation, but under twice on class B. The polarisation index (PI), the ratio of the insulation resistance after 1010 and after 11 minute at a DC test voltage, shows whether the insulation is clean and dry: in good insulation the absorption current keeps falling, so the resistance keeps rising; moisture and dirt give a flat reading. IEEE Std 43-2013 recommends a PI of at least 2.0 for class B and higher insulation.

Testing

Tests are grouped by when they are done; many use high voltage and are only for trained staff with proper equipment, never for learners:

  • Routine (factory) tests: winding resistance, no-load current and losses, high-voltage withstand (IEC 60034-1 calls for 1000 V+2×1000\ \text{V} + 2 \times rated voltage, at least 1500 V1500\ \text{V}, for one minute on a new low-voltage winding), rotation direction.
  • Type tests: heat run, efficiency, locked-rotor current and torque (No-Load and Blocked-Rotor Tests), noise, vibration. Efficiency is determined to IEC 60034-2-1 (edition 3.0, 2024, which replaced the 2014 edition; its preferred method for induction motors is summation of losses with the stray load loss measured from the residual loss) or IEEE Std 112-2017 method B in North America.
  • Maintenance tests: insulation resistance and PI with a megohmmeter (500500 or 1000 V1000\ \text{V} DC for low-voltage machines), winding resistance balance between phases (more than a few percent of imbalance suggests shorted turns or a bad joint), surge comparison tests, partial-discharge measurements on high-voltage machines.

Maintenance and condition monitoring

Surveys of industrial motors usually find bearings to be the largest single cause of failure, followed by the stator winding; the shares differ between studies, voltage levels and industries. Maintenance therefore centres on:

  • Lubrication on schedule and with the right grease (over-greasing overheats bearings too).
  • Cleaning fins and fan covers; blocked cooling raises the winding temperature and halves life every 10 K.
  • Vibration monitoring (ISO 20816-1 for the evaluation of vibration) to catch unbalance, misalignment and bearing defects; bearing faults show at characteristic frequencies in the spectrum.
  • Thermography of terminal boxes, bearings and frames.
  • Motor current signature analysis (MCSA): broken rotor bars and eccentricity create sidebands around the supply frequency in the stator current.
  • For DC machines, brushes and commutator: brush length, spring pressure, commutator film and wear.

Interactive: heating as an RC circuit

A machine heats like a capacitor charging through a resistor (heat capacity CC, thermal resistance RR, losses as the "current"); the rise follows Δθ∞(1−e−t/τ)\Delta\theta_\infty(1 - e^{-t/\tau}) with the thermal time constant τ=RthCth\tau = R_\text{th}C_\text{th}, from minutes for small motors to hours for large ones. In the lab read 1 V1\ \text{V} as 4 K4\ \text{K} (so 20 V20\ \text{V} is a final rise of 80 K80\ \text{K}) and the time axis in units of τ\tau: after 1τ1\tau the lab shows 12.6 V12.6\ \text{V} (about 50 K50\ \text{K}, 63.2 %), after 3τ3\tau 19.0 V19.0\ \text{V} (95 %).

+-R = 1.00 kOhmswitch closed at t = 0V = 20.0 V, C = 10.0 uFtau = RC = 10.0 mst60.0 mst/tau6.00vC20.0 Vi49.6 uAvR49.6 mV0.05.010.015.020.001 tau2 tau3 tau4 tau5 tau6 tautv (V)0 A10 mA20 mAi63.2 %5 tau: 99.3 %vC(t), capacitor voltagei(t)

Switch to "discharge": the cooling curve after switch-off, which is why R2R_2 must be read quickly and extrapolated back.

Guided lab: temperature rise of a small motor by resistance

Hand calculation. For a small PMDC motor, predict the steady rise from its losses and a guessed thermal resistance (a few tens of K/W for a can motor), and the resistance increase: 0.39 %0.39\ \% per K.

Simulation. The RC analogue above or a one-line first-order model in Python with your loss and RthR_\text{th}.

What you would measure. Measure the winding resistance cold (rotor clamped, two or three rotor positions, four-wire if below 1 Ω1\ \Omega; note the room temperature). Run the motor loaded for 20 to 30 minutes from a current-limited supply, switch off, and measure the resistance again within seconds, then every 10 seconds for a minute, and extrapolate back to switch-off. Expect rises of 20 to 60 K depending on load; the uncertainty is dominated by the brush contact resistance (±5\pm 5 to 10 K10\ \text{K}), which a four-wire measurement on the brush terminals cannot remove.

Hazards and safe setup. At most 24 V24\ \text{V}, current-limited; clamp the motor; keep fingers and hair away from the shaft; the can may exceed 60 ∘C60\,^\circ\text{C}. Do not use an insulation tester (megohmmeter) or a hipot tester: their test voltages (500 V500\ \text{V} and more) are hazardous and are for trained staff only.

Pitfalls

  • Measuring the hot resistance too late. A small winding cools noticeably in a minute; extrapolate back to switch-off.
  • Ignoring altitude and ambient. The rise limits assume 40 ∘C40\,^\circ\text{C} and 1000 m1000\ \text{m}; thinner air cools less.
  • Equating the insulation class with the allowed rise. The rise limit is lower than the class temperature minus ambient, to cover the hot spot.

Practice

  1. A copper winding reads 2.40 Ω2.40\ \Omega at 22 ∘C22\,^\circ\text{C} and 3.05 Ω3.05\ \Omega hot with 30 ∘C30\,^\circ\text{C} ambient. Find the rise.
  2. A class F motor's hot spot runs at 135 ∘C135\,^\circ\text{C}. Estimate its life relative to the class rating.
  3. An insulation test gives 400 MΩ400\ \text{M}\Omega at 1 min and 560 MΩ560\ \text{M}\Omega at 10 min. Find the PI and judge it.
Answer
  1. θ2=(3.05/2.40)(256.5)−234.5=325.97−234.5=91.5 ∘C\theta_2 = (3.05/2.40)(256.5) - 234.5 = 325.97 - 234.5 = 91.5\,^\circ\text{C}; rise 61.5 K61.5\ \text{K}.
  2. 2(155−135)/10=42^{(155 - 135)/10} = 4 times.
  3. PI=1.4\text{PI} = 1.4: below 2.0, investigate (dry out, clean, retest).

Test yourself

What is the thermal class temperature of class F insulation (IEC 60085)?

  1. 130 ∘C130\,^\circ\text{C}
  2. 155 ∘C155\,^\circ\text{C}
  3. 180 ∘C180\,^\circ\text{C}
  4. 105 ∘C105\,^\circ\text{C}

By the 10 K rule, a winding that runs 20 K hotter than its rated temperature has about…

  1. the same life
  2. half the life
  3. a quarter of the life
  4. a tenth of the life

IC 411 describes…

  1. an open drip-proof motor
  2. a totally enclosed motor cooled by a shaft-mounted fan over a finned frame
  3. a water-cooled motor
  4. a motor with a separately powered fan

A cold winding reads 0.800 Ω0.800\ \Omega at 20 ∘C20\,^\circ\text{C} and 1.090 Ω1.090\ \Omega hot. The hot temperature is about…

  1. 82 ∘C82\,^\circ\text{C}
  2. 98 ∘C98\,^\circ\text{C}
  3. 112 ∘C112\,^\circ\text{C}
  4. 136 ∘C136\,^\circ\text{C}

Which is the most common single cause of failure in industrial induction motors, according to most surveys?

  1. rotor bars
  2. bearings
  3. the shaft
  4. the nameplate