Stepper, Switched-Reluctance, Universal and Linear Motors
Not every motion problem wants a smooth, efficient rotation. A 3-D printer wants to move a nozzle by exactly and hold it there, with no position sensor. A mining truck's hub motor wants to survive heat, dust and overload with no magnets to demagnetise. A kitchen blender wants from the mains, cheaply. A sorting conveyor or a maglev train wants force in a straight line. Each of these has its own machine: the stepper motor, the switched-reluctance motor, the universal motor and the linear motor. They all follow from ideas you already have: reluctance torque from Doubly Excited Systems, the series motor from DC Motors, and the travelling field of The Rotating Magnetic Field.
Stepper motors
A stepper turns by a fixed angle for each change of its winding currents, and stops there. Three types:
| Type | Rotor | Typical step | Notes |
|---|---|---|---|
| Variable reluctance (VR) | toothed soft iron, no magnet | to | reluctance torque only; no detent torque when unpowered |
| Permanent magnet (PM, "tin-can") | radially magnetised | , | cheap, low resolution; small detent torque |
| Hybrid | two toothed iron caps around an axial magnet | (200 steps/rev), | the common one in printers and CNC |
A two-phase hybrid with rotor teeth has a full step of . Full stepping energises the phases in the sequence A, B, A, B (or two phases at a time for more torque); half stepping alternates one-phase and two-phase states for ; microstepping feeds the phases with currents and so the rest position moves continuously, in 16 or more microsteps per full step.
Around each rest position the motor acts like a torsion spring. Its static torque–angle curve is close to
where is the holding torque and the rotor's mechanical displacement from the commanded position. A load torque moves the rest point back by ; if exceeds the rotor slips to the next stable point and loses steps, and since a stepper usually runs open loop, the controller never knows.
The dynamic limits come from the windings: each phase is an RL circuit, so at high step rates the current cannot reach its set value within one step and the torque falls. Datasheets give a pull-in curve (the torque at which the motor can start and stop at a given step rate without ramping) and a higher pull-out curve (the torque it can hold once running, if accelerated gradually). Mid-range resonance, where the rotor oscillates around each step, causes noise and lost steps; microstepping and damping reduce it.
Switched-reluctance motors
A switched-reluctance motor (SRM) has salient poles on both stator and rotor (for example 8 stator and 6 rotor poles), coils on the stator only, and no magnets. A phase is switched on while the rotor poles approach it, so its inductance is rising; the co-energy method gives, without saturation,
Torque depends on , so the current direction does not matter and a simple asymmetric half-bridge per phase drives it. SRMs are rugged, cheap and tolerate high temperature, but have torque ripple and acoustic noise; they are used in some appliances, mining and industrial drives.
Universal motors
A universal motor is a series DC motor built to run on AC: laminated field and armature, few field turns to keep the reactance low. Because field and armature carry the same current, the torque keeps its sign on both half-cycles; it pulsates at twice the supply frequency. Series characteristic means high no-load speed ( to ), so universal motors give high power per kilogram in drills, vacuum cleaners, blenders and angle grinders, with speed control by a triac phase controller. Brushes and commutator limit their life. These run from the mains: in this course, calculation only.
Linear motors
Cut a rotating machine along a radius and unroll it: the stator becomes a straight row of coils whose currents produce a field travelling at the synchronous speed
with pole pitch and supply frequency . A linear synchronous motor (magnet track) moves at exactly and is used in machine tools, semiconductor wafer stages and maglev; a linear induction motor (a conducting plate as the "rotor") slips behind and drives some metros and conveyors. End effects (the field must start and end) and a large air gap make linear motors less efficient than rotating ones.
Worked example: a stepper on a lead screw
Given: a two-phase hybrid stepper with and holding torque , driving a lead screw of per revolution; 16 microsteps per full step; full steps per second; load torque .
Find: the resolution per full step and per microstep, the speed, and the position error caused by the load.
Solve:
Check: the load error () is three microsteps: microstepping gives fine resolution, not equally fine accuracy under load. The motor still holds position as long as at that speed.
In Python: the numbers of four special machines
import numpy as np
# hybrid stepper: 2 phases, Nr = 50 rotor teeth, holding torque Th
m, Nr, Th = 2, 50, 0.40 # phases, teeth, N m
full = 360 / (2 * m * Nr)
print(f"full step {full:.2f} deg ({360/full:.0f} steps/rev), half step {full/2:.2f} deg")
# microstepping: phase currents I cos(a), I sin(a) put the equilibrium at a/Nr (mechanical)
# a load torque TL shifts the rotor back by asin(TL/Th)/Nr
for TL in (0.0, 0.12, 0.28):
lag = np.degrees(np.arcsin(TL / Th)) / Nr
print(f"load {TL:.2f} N m: rotor lags its commanded angle by {lag:.3f} deg = {lag/full:.2f} full steps")
# a stepper loses steps when the load exceeds the holding torque at that speed (pull-out)
# linear axis: 2 mm lead screw, 16 microsteps per full step, 1000 full steps/s
lead, micro, rate = 2.0, 16, 1000
print(f"axis: {lead/(360/full)*1e3:.1f} um per full step, {lead/(360/full)/micro*1e3:.3f} um per microstep, "
f"{rate*full/360*60:.0f} rpm = {rate*full/360*lead:.1f} mm/s")
# switched reluctance: T = 1/2 i^2 dL/dtheta (unsaturated), L rising 10 -> 60 mH over 15 deg
dL = (60e-3 - 10e-3) / np.radians(15)
for i in (5, 10, 15):
print(f"SRM: i = {i:2d} A, dL/dtheta = {dL:.4f} H/rad, T = {0.5*i*i*dL:6.2f} N m")
# universal motor on AC: T = c i^2, so torque pulsates at twice the supply frequency but never reverses
f, Irms, c = 50, 4.0, 0.015
t = np.linspace(0, 0.02, 20001)
Tt = c * (np.sqrt(2) * Irms * np.sin(2 * np.pi * f * t)) ** 2
print(f"universal motor: mean torque {Tt.mean():.3f} N m (c Irms^2 = {c*Irms**2:.3f}), min {Tt.min():.3f}, max {Tt.max():.3f}")
# linear synchronous motor: travelling field at v = 2 tau_p f
for tau_p, f in ((0.10, 50), (0.03, 20)):
print(f"linear motor: pole pitch {tau_p*1e3:.0f} mm at {f} Hz -> {2*tau_p*f:.2f} m/s")full step 1.80 deg (200 steps/rev), half step 0.90 deg
load 0.00 N m: rotor lags its commanded angle by 0.000 deg = 0.00 full steps
load 0.12 N m: rotor lags its commanded angle by 0.349 deg = 0.19 full steps
load 0.28 N m: rotor lags its commanded angle by 0.889 deg = 0.49 full steps
axis: 10.0 um per full step, 0.625 um per microstep, 300 rpm = 10.0 mm/s
SRM: i = 5 A, dL/dtheta = 0.1910 H/rad, T = 2.39 N m
SRM: i = 10 A, dL/dtheta = 0.1910 H/rad, T = 9.55 N m
SRM: i = 15 A, dL/dtheta = 0.1910 H/rad, T = 21.49 N m
universal motor: mean torque 0.240 N m (c Irms^2 = 0.240), min 0.000, max 0.480
linear motor: pole pitch 100 mm at 50 Hz -> 10.00 m/s
linear motor: pole pitch 30 mm at 20 Hz -> 1.20 m/s
The SRM torque grows with until the iron saturates (then roughly with ). The universal motor's torque swings between and twice its mean, times a second on a supply, but never reverses.
Interactive: why steppers lose torque at speed
A small stepper phase with and has . After one time constant the lab shows , 63.2 % of the final . At full steps per second a phase is reversed every , only two time constants, so it never reaches full current.
Raise to : the current now reaches in instead of approaching it slowly. That is what a chopper drive does: a supply several times the rated phase voltage forces the current up fast, and the driver switches off whenever the current reaches its set value.
Guided lab: count steps and find the stall point
Hand calculation. For your stepper (often ; NEMA 17 size motors have holding torques of a few tenths of N·m), compute steps per revolution, the phase , and the step rate at which is half a step period.
Simulation. The RL lab with your phase and ; the Python cell with your and load.
What you would measure. Use a ready-made stepper driver module with current limiting, set to the motor's rated phase current, on a bench supply of to with its own current limit, stepped by a function generator (or a microcontroller) at known rates. Mark the shaft with tape: 200 pulses (full step) or 3200 (16 microsteps) should give exactly one turn. Increase the step rate gradually: the motor runs, then at some rate (typically a few hundred to a few thousand full steps per second) it stalls and buzzes; ramping the rate up lets it reach higher speed (pull-out above pull-in). Measure the phase current on a current probe or a sense resistor and watch it fail to reach its set value at high rates.
Hazards and safe setup. At most , current-limited. Never connect or disconnect a motor wire while the driver is powered: the inductive kick destroys the driver. Steppers get hot at standstill (full current while holding): to cases are normal, so don't grab them. Clamp the motor; keep fingers off pulleys and lead screws.
Pitfalls
- Assuming open-loop position is guaranteed. Overload or resonance loses steps silently; critical axes add an encoder or a homing switch.
- Microsteps as accuracy. The torque per microstep is small and the static error under load can be several microsteps.
- Driving a stepper from its rated voltage at high speed. Torque collapses; use a chopper drive at a higher supply voltage.
- Running a universal motor unloaded on a test bench. It is a series motor: very high speed.
Practice
- A VR stepper has 8 stator poles (4 phases) and 6 rotor teeth. Its step angle is . Find it.
- A stepper with carries . Find the lag in degrees ().
- A linear motor has a pole pitch of . What frequency gives ?
Answer
- (24 steps per revolution).
- , (a third of a full step).
- .
Test yourself
A two-phase hybrid stepper has 50 rotor teeth. Its full-step angle is…
Why does a stepper's available torque fall at high step rates?
- the magnets weaken
- the phase current cannot rise to its set value within a step (L/R) and back-EMF grows
- the holding torque is a dynamic limit
- the rotor teeth saturate
The torque of a switched-reluctance motor phase is . What follows?
- it needs bipolar current
- the current direction does not matter, so a unipolar converter suffices
- it needs permanent magnets
- it has no torque ripple
A universal motor runs on AC because…
- it has a capacitor
- field and armature current reverse together, so keeps its sign
- the commutator rectifies the supply
- it is a synchronous motor