Most homes have no three-phase supply, yet washing machines, refrigerator compressors, garden pumps, desk fans and bench grinders all use induction motors. A single winding on a single-phase supply makes only a pulsating field, which cannot start a rotor. This lesson explains why such a motor nevertheless runs once it is turning, and the tricks (an auxiliary winding, a capacitor, a shaded pole) that get it started. The second half turns the machine around: drive an induction machine above synchronous speed and it becomes a generator, the workhorse of early wind farms and of many small hydro plants.

Safety: single-phase motors run from 230 V230\ \text{V} mains and induction generators feed the grid; both are calculation and simulation only here. Motor-run capacitors keep a charge after switch-off, and a self-excited induction generator can produce dangerous voltage with no grid connected at all.

The double-revolving-field idea

A pulsating MMF Fmcos⁡ωtcos⁡θF_m\cos\omega t\cos\theta is the sum of two half-amplitude waves turning in opposite directions:

Fmcos⁡ωtcos⁡θ=12Fmcos⁡(θ−ωt)+12Fmcos⁡(θ+ωt)F_m\cos\omega t\cos\theta = \tfrac12 F_m\cos(\theta - \omega t) + \tfrac12 F_m\cos(\theta + \omega t)

A rotor turning forward at slip ss relative to the forward field has slip 2−s2 - s relative to the backward one. Each field produces its own torque–slip curve, in opposite directions. At standstill (s=1s = 1) the two slips are equal, the torques cancel and there is no starting torque. Once the rotor turns forward the forward torque dominates, so the motor runs (in either direction, depending on which way it was pushed). The equivalent circuit puts two half-size magnetising-and-rotor branches in series, one with R2′/sR_2'/s, one with R2′/(2−s)R_2'/(2 - s):

ZF=12 jXm (R2′/s+jX2′)jXm+R2′/s+jX2′,ZB=12 jXm (R2′/(2−s)+jX2′)jXm+R2′/(2−s)+jX2′Z_F = \tfrac12\,\frac{jX_m\,(R_2'/s + jX_2')}{jX_m + R_2'/s + jX_2'}, \qquad Z_B = \tfrac12\,\frac{jX_m\,(R_2'/(2-s) + jX_2')}{jX_m + R_2'/(2-s) + jX_2'}
T=I12 (Re⁡ZF−Re⁡ZB)ωsT = \frac{I_1^2\,(\operatorname{Re} Z_F - \operatorname{Re} Z_B)}{\omega_s}

The backward field costs torque and losses even at running speed, which is one reason single-phase motors are less efficient and noisier (a torque pulsation at 2f2f) than three-phase motors of the same size.

Starting methods

To start, the motor needs a second winding displaced 90∘90^\circ electrical in space, the auxiliary (start) winding, carrying a current displaced in time from the main winding current. Two windings in quadrature with currents near quadrature make a (roughly) rotating field.

230 V50 Hz mainwinding centrifugal switch(opens near 75 % speed) aux winding C start I main (lags) I aux (leads) windings 90 deg apart (electrical) in the stator
Type How the phase shift is made Starting torque Typical use
Split-phase auxiliary winding of thin wire: higher R/XR/X, current lags less; switched out at 70–80 % speed moderate, high current small fans, older washers
Capacitor-start electrolytic start capacitor in the auxiliary branch makes its current lead; switched out high (2–3 TNT_N) compressors, pumps, workshop machines
Permanent split capacitor (capacitor-run) small film capacitor stays in circuit low fans, blowers, air handlers; quiet, better pf and efficiency
Capacitor-start, capacitor-run large start and small run capacitor high larger single-phase motors up to a few kW
Shaded pole a copper ring around part of each pole delays the flux under it very low small fans, under about 50 W50\ \text{W}; low efficiency, often well under 40 %

The centrifugal switch (or an electronic relay) matters: the start capacitor and the thin auxiliary winding are rated only for a few seconds of current. A motor that fails to reach switch-out speed burns its start winding.

Interactive: the two winding currents at standstill

The phasor lab draws one branch at a time. Take a small capacitor motor's windings at standstill, scaled to 24 V24\ \text{V} (the angles do not depend on voltage). The main winding (10 Ω10\ \Omega, 50 mH50\ \text{mH}) draws a current lagging by 57.5∘57.5^\circ:

ReImVRVLVIphi = 57.5 deg, I lags(I drawn on its own scale)-pk0+pk0T/2T3T/22Tv(t), peak 33.9 Vi(t), peak 1.82 Aimpedance trianglepower triangleRX|Z|PQSR = 10.0 OhmP = 16.6 WX = 15.7 OhmQ = 26.1 var|Z| = 18.6 OhmS = 30.9 VApf = cos phi = 0.537 lagging

The auxiliary winding (20 Ω20\ \Omega, 60 mH60\ \text{mH}) in series with 100 μF100\ \mu\text{F} draws a current leading by 33.0∘33.0^\circ. The two currents are 57.5∘+33.0∘=90.5∘57.5^\circ + 33.0^\circ = 90.5^\circ apart: almost a perfect two-phase set. Change CC and watch the phase.

ReImVRVLVCVIphi = -33.0 deg, I leads(I drawn on its own scale)-pk0+pk0T/2T3T/22Tv(t), peak 33.9 Vi(t), peak 1.42 Aimpedance trianglepower triangleRX|Z|PQSR = 20.0 OhmP = 20.3 WX = -13.0 OhmQ = -13.2 var|Z| = 23.8 OhmS = 24.2 VApf = cos phi = 0.839 leading

Worked example: a 0.75 kW single-phase motor

Given: 230 V230\ \text{V}, 50 Hz50\ \text{Hz}, 4 poles; main-winding circuit R1=2.4 ΩR_1 = 2.4\ \Omega, X1=3.0 ΩX_1 = 3.0\ \Omega, Xm=100 ΩX_m = 100\ \Omega, R2′=4.5 ΩR_2' = 4.5\ \Omega, X2′=3.0 ΩX_2' = 3.0\ \Omega; rotational loss 25 W25\ \text{W}; running on the main winding at s=0.05s = 0.05.

Find: speed, current, power factor, torque, output and efficiency.

Solve: n=0.95⋅1500=1425 rpmn = 0.95 \cdot 1500 = 1425\ \text{rpm}. With R2′/s=90 ΩR_2'/s = 90\ \Omega and R2′/(2−s)=2.31 ΩR_2'/(2 - s) = 2.31\ \Omega:

ZF=24.05+j22.47 Ω,ZB=1.087+j1.481 ΩI1=230 V∣2.4+j3.0+ZF+ZB∣=230 V38.53 Ω=5.97 A,pf=0.715T=5.972 A2 (24.05−1.087) Ω157.08 rad/s=5.21 N mPout=5.21 N m⋅149.2 rad/s−25 W=752 W,η=752 W230⋅5.97⋅0.715 W=76.6 %\begin{aligned} Z_F &= 24.05 + j22.47\ \Omega, \qquad Z_B = 1.087 + j1.481\ \Omega \\ I_1 &= \frac{230\ \text{V}}{\lvert 2.4 + j3.0 + Z_F + Z_B \rvert} = \frac{230\ \text{V}}{38.53\ \Omega} = 5.97\ \text{A}, \quad \text{pf} = 0.715 \\ T &= \frac{5.97^2\ \text{A}^2\,(24.05 - 1.087)\ \Omega}{157.08\ \text{rad/s}} = 5.21\ \text{N m} \\ P_\text{out} &= 5.21\ \text{N m} \cdot 149.2\ \text{rad/s} - 25\ \text{W} = 752\ \text{W}, \qquad \eta = \frac{752\ \text{W}}{230 \cdot 5.97 \cdot 0.715\ \text{W}} = 76.6\ \% \end{aligned}

Check: the output is the rated 0.75 kW0.75\ \text{kW}; 77 % is typical of a single-phase motor this size (a three-phase IE3 motor of 0.75 kW0.75\ \text{kW} reaches about 82 %). The backward field takes 5.972⋅1.087=39 W5.97^2 \cdot 1.087 = 39\ \text{W} of air-gap power the wrong way.

In Python: torque against speed on one winding

python · try it yourself
import numpy as np
V, f, p = 230.0, 50, 4
ws = 4 * np.pi * f / p
R1, X1, Xm, R2, X2 = 2.4, 3.0, 100.0, 4.5, 3.0        # main winding, rotor referred to it (ohm)
P_rot = 25.0                                          # friction, windage, core (W)

def half(Rr):                                         # half of the magnetising and rotor branch
    Zr = Rr + 1j * X2
    return 0.5 * (1j * Xm * Zr) / (1j * Xm + Zr)

def run(s):
    ZF, ZB = half(R2 / s), half(R2 / (2 - s))
    I = V / (R1 + 1j * X1 + ZF + ZB)
    PF, PB = abs(I)**2 * ZF.real, abs(I)**2 * ZB.real   # air-gap powers of the two fields
    T = (PF - PB) / ws
    P_out = T * ws * (1 - s) - P_rot
    return abs(I), np.cos(np.angle(I)), T, P_out

print("  s     n (rpm)   I (A)    pf    T (N m)  P_out (W)")
for s in (1.0, 0.5, 0.2, 0.1, 0.06, 0.05, 0.04):
    I, pf, T, P = run(s)
    print(f"{s:5.2f}  {1500*(1-s):7.0f}  {I:6.2f}  {pf:5.3f}  {T:7.3f}  {P:8.1f}")
  s     n (rpm)   I (A)    pf    T (N m)  P_out (W)
 1.00        0   25.53  0.736    0.000     -25.0
 0.50      750   22.52  0.785    9.029     684.1
 0.20     1200   14.43  0.859   11.853    1464.5
 0.10     1350    9.07  0.841    8.744    1211.1
 0.06     1410    6.57  0.760    6.050     868.3
 0.05     1425    5.97  0.715    5.208     752.2
 0.04     1440    5.40  0.650    4.294     622.6

At standstill the torque is exactly zero while the current is highest: without the auxiliary winding the motor just hums and heats. Pushed to any speed, it accelerates.

Induction generators

Drive the rotor faster than nsn_s and the slip goes negative. Then R2′/s<0R_2'/s < 0: the "load resistor" becomes a source, Pag<0P_\text{ag} < 0, and power flows from the shaft through the air gap into the stator and the grid. The machine still needs its magnetising current, so it takes reactive power while it delivers real power.

python · try it yourself
import numpy as np
V = 400 / np.sqrt(3); ws = 4 * np.pi * 50 / 4
R1, X1, Xm, R2, X2 = 0.55, 1.0, 32.0, 0.45, 1.4      # the example 7.5 kW motor
P_rot = 220.0
print("   s     n (rpm)  shaft in (W)  to grid P (W)  from grid Q (var)  efficiency")
for s in (-0.01, -0.0255, -0.04):
    Z2 = R2 / s + 1j * X2
    I1 = V / (R1 + 1j * X1 + 1j * Xm * Z2 / (1j * Xm + Z2))
    I2 = I1 * 1j * Xm / (1j * Xm + Z2)
    S = 3 * V * np.conj(I1)                           # power taken from the grid (motor convention)
    P_ag = 3 * abs(I2)**2 * R2 / s                    # negative: power flows from rotor to stator
    P_shaft = -(1 - s) * P_ag + P_rot                 # mechanical power that must be supplied
    print(f"{s:7.4f}  {1500*(1-s):7.1f}  {P_shaft:10.0f}  {-S.real:12.0f}  {S.imag:14.0f}      {-S.real/P_shaft*100:5.1f} %")
Xc = X1 + Xm                                          # no-load self-excitation: capacitor cancels X1 + Xm
C = 1 / (2 * np.pi * 50 * Xc)
print(f"self-excitation at no load: about {C*1e6:.0f} uF per phase (star), {3*V**2/Xc/1e3:.2f} kvar in total")
   s     n (rpm)  shaft in (W)  to grid P (W)  from grid Q (var)  efficiency
-0.0100   1515.0        3665          3283            5140       89.6 %
-0.0255   1538.3        9321          8489            6330       91.1 %
-0.0400   1560.0       14781         13171            8251       89.1 %
self-excitation at no load: about 96 uF per phase (star), 4.85 kvar in total

At 1538 rpm1538\ \text{rpm} (s=−0.0255s = -0.0255) the example motor delivers 8.5 kW8.5\ \text{kW} to the grid while drawing 6.3 kvar6.3\ \text{kvar} from it. Real power output rises steeply with speed, so a cage generator on the grid runs at nearly constant speed, just above synchronous. That made it the simple, robust choice for the fixed-speed "Danish concept" wind turbines of the 1980s–90s, with capacitor banks for power-factor correction. Most modern turbines use a doubly-fed induction generator (rotor fed through a converter) or a synchronous machine behind a full converter (Power Systems, Power Electronics).

Self-excitation. Without a grid, capacitors across the terminals can supply the magnetising current. Residual magnetism starts a small voltage; the capacitor current builds the flux up until the magnetising curve saturates and the voltage settles where the capacitor line meets it (the same build-up as a DC shunt generator). At no load the example machine needs roughly 96 μF96\ \mu\text{F} per phase; under load it needs more, and the voltage and frequency both drift with load and speed. Self-excitation is also a hazard: a motor with power-factor capacitors that is disconnected while coasting can self-excite and hold its terminals at a high voltage for a while.

Guided lab (simulation and low-voltage demonstration)

Hand calculation. Repeat the worked example at s=0.04s = 0.04 and compare with the code's table.

Simulation. In the auxiliary-winding lab, find the capacitance that puts the two currents exactly 90∘90^\circ apart.

What you would measure. Single-phase mains motors and grid-connected generators are not learner experiments. A safe analogue of generator action uses a hand-cranked or drill-driven small DC motor (12 V permanent-magnet type) as a generator into a 10 Ω10\ \Omega resistor, with a meter: the output rises in proportion to speed, and the crank gets harder to turn as the load resistance falls, energy conservation you can feel. Expect a few volts at a few hundred rpm (read the motor's speed constant from its datasheet, ±10 %\pm 10\ \%). Keep fingers and hair clear of the rotating shaft and coupling, secure the motor in a clamp, and never connect a "generator" to a battery or supply.

Pitfalls

  • Assuming a single-phase motor has some starting torque. On the main winding alone it has none; a failed start capacitor or switch leaves it humming and overheating.
  • Using an electrolytic start capacitor as a run capacitor. It is rated for seconds of duty; run capacitors are film types.
  • Forgetting reactive power in generators. An induction generator always absorbs reactive power; the grid or capacitors must supply it.
  • Islanding. A self-excited generator can keep a disconnected network live, a danger to line workers; grid codes require protection against it.

Practice

  1. A single-phase rotor runs at s=0.04s = 0.04. What is its slip relative to the backward field?
  2. In the worked example, how much does the backward field reduce the torque, in N m?
  3. The example machine generates at s=−0.04s = -0.04. From the table, what are its output and reactive power demand?
Answer
  1. 2−0.04=1.962 - 0.04 = 1.96.
  2. 5.972⋅1.087/157.08=0.247 N m5.97^2 \cdot 1.087/157.08 = 0.247\ \text{N m} (about 5 % of the forward torque).
  3. About 13.2 kW13.2\ \text{kW} to the grid, taking 8.3 kvar8.3\ \text{kvar} (and needing 14.8 kW14.8\ \text{kW} at the shaft).

Test yourself

Why has a single-winding single-phase induction motor no starting torque?

  1. its rotor is too heavy
  2. at standstill the forward and backward fields produce equal and opposite torques
  3. the supply is DC at start
  4. the slip is zero

In a capacitor-start motor the capacitor is in series with…

  1. the main winding
  2. the auxiliary winding
  3. the rotor
  4. the supply fuse only

An induction machine connected to the grid runs at 1530 rpm (4 poles, 50 Hz). It…

  1. motors with s = 0.02
  2. generates with s = −0.02
  3. brakes with s = 1.02
  4. runs synchronously

What does an induction generator need from the grid (or capacitors) even while it delivers real power?

  1. DC excitation current
  2. reactive power for magnetisation
  3. nothing
  4. a starting capacitor