Speed Control and Braking of DC Motors
The DC motor was the variable-speed drive of the twentieth century: rolling mills, paper machines, lifts, electric trains. It earned that place because its speed equation has three handles that are easy to reach, the armature voltage, the field flux and the armature-circuit resistance, and because the same machine brakes simply by becoming a generator. Brushless and induction drives have taken over most new installations, but they are controlled to imitate a separately excited DC motor, so its speed-control and braking regions are still the reference every drive engineer thinks in. This lesson applies all three handles to one motor, then stops it four ways and follows where the energy goes.
Three ways to change the speed
From the previous lesson:
| Method | What changes | Effect | Region |
|---|---|---|---|
| Armature voltage | no-load speed , slope unchanged | efficient, smooth, full torque at every speed | 0 to base speed: constant torque |
| Field weakening | no-load speed , slope | rated current now gives less torque | above base speed: constant power |
| Armature resistance | slope steeper, no-load speed unchanged | wastes ; speed depends strongly on load | only for short duty or starting |
Below base speed (rated speed at full field and full voltage) the drive lowers the armature voltage; above it, the voltage is at its limit and the field is weakened. The current limit stays the same throughout, so the torque available falls as above base speed while the power stays at its rating. Field weakening is limited by commutation and by mechanical speed (often to two to four times base speed). Modern drives get the variable armature voltage from a controlled rectifier or a chopper (Power Electronics & Motor Drives); the classic rotating version was the Ward-Leonard set, a motor-generator whose generator field set the motor's armature voltage.
Four ways to stop
| Method | Connection | Energy goes to | Notes |
|---|---|---|---|
| Coasting | supply off | friction and windage | slow, uncontrolled |
| Dynamic (rheostatic) braking | armature disconnected from the supply and connected to a resistor ; field kept on | the resistor | braking torque , so it fades at low speed |
| Plugging (counter-current) | armature polarity reversed, with resistance | resistor and armature: the kinetic energy plus energy from the supply | fastest; must disconnect at zero speed or the motor reverses |
| Regenerative braking | supply stays connected and can absorb power; | back into the supply | only when the supply can accept it (a regenerative converter, a battery, a traction line) |
Regeneration also happens on its own: a lift lowering a heavy car or a train on a downhill grade drives the motor above its no-load speed, exceeds and the current reverses.
Worked example: control and braking of one motor
Given: the shunt motor of DC Motors: , at full field, rated , , . Rotor plus load inertia , friction torque .
Find: the speed at rated torque with , with 80 % flux, and with in the armature; the braking resistors that limit the first braking current to from .
Solve:
Check: the added wastes while the motor delivers : almost a fifth of the input is burned, which is why resistance control is reserved for starting. Plugging needs more than twice the resistance because the supply voltage and the back-EMF now add. This is a mains-derived industrial drive: calculation and simulation only.
In Python: speeds, stopping times and where the energy goes
import numpy as np
from scipy.integrate import solve_ivp
# the 220 V shunt motor of the last lesson (calculation only)
V, Ra, kphi = 220.0, 0.4, 1.2987
rpm = lambda w: w * 60 / (2 * np.pi)
print("speed control at rated torque 51.95 N m:")
print(f" V = 110 V: {rpm((110 - 40*Ra)/kphi):5.0f} rpm, Ia = 40.0 A")
k2 = 0.8 * kphi
print(f" flux 80 %: {rpm((V - 50*Ra)/k2):5.0f} rpm, Ia = {51.95/k2:.1f} A")
print(f" 1 ohm in the armature: {rpm((V - 40*(Ra+1))/kphi):5.0f} rpm, resistor loss {40**2*1:.0f} W")
# stopping from 1500 rpm: rotor + load inertia J, friction torque 3.82 N m (600 W at 1500 rpm)
J, Tf, w0 = 0.5, 3.82, 2 * np.pi * 1500 / 60
E0 = kphi * w0
Rdb = E0 / 80 - Ra # dynamic braking: limit the first current to 80 A
Rpl = (V + E0) / 80 - Ra # plugging: supply reversed, same 80 A limit
print(f"E at 1500 rpm = {E0:.1f} V; dynamic-braking resistor {Rdb:.3f} ohm; plugging resistor {Rpl:.3f} ohm")
print(f"kinetic energy at 1500 rpm = {0.5*J*w0**2/1e3:.2f} kJ")
def run(name, ia, Rtot):
stop = lambda t, x: x[0] - 1e-3 # end when the shaft has stopped
stop.terminal = True
s = solve_ivp(lambda t, x: [(-kphi * ia(x[0]) - Tf) / J], (0, 60), [w0],
events=stop, max_step=0.01, rtol=1e-8)
i = np.array([ia(w) for w in s.y[0]])
heat = Rtot * float(np.sum(0.5 * (i[1:]**2 + i[:-1]**2) * np.diff(s.t))) # R * integral of i^2 dt
print(f" {name:9s}: stops in {s.t[-1]:6.2f} s, first current {ia(w0):5.1f} A, heat in the armature circuit {heat/1e3:5.2f} kJ")
run("coasting", lambda w: 0.0, 0.0)
run("dynamic", lambda w: kphi * w / (Ra + Rdb), Ra + Rdb)
run("plugging", lambda w: (V + kphi * w) / (Ra + Rpl), Ra + Rpl)
# regeneration: an overhauling load drives the shaft to 1700 rpm with the supply connected
E = kphi * 2 * np.pi * 1700 / 60
print(f"regenerating at 1700 rpm: E = {E:.1f} V, current back into the supply {(E - V)/Ra:.1f} A")speed control at rated torque 51.95 N m:
V = 110 V: 691 rpm, Ia = 40.0 A
flux 80 %: 1838 rpm, Ia = 50.0 A
1 ohm in the armature: 1206 rpm, resistor loss 1600 W
E at 1500 rpm = 204.0 V; dynamic-braking resistor 2.150 ohm; plugging resistor 4.900 ohm
kinetic energy at 1500 rpm = 6.17 kJ
coasting : stops in 20.56 s, first current 0.0 A, heat in the armature circuit 0.00 kJ
dynamic : stops in 2.52 s, first current 80.0 A, heat in the armature circuit 5.77 kJ
plugging : stops in 0.98 s, first current 80.0 A, heat in the armature circuit 18.58 kJ
regenerating at 1700 rpm: E = 231.2 V, current back into the supply 28.0 A
Dynamic braking turns almost all of the of kinetic energy into heat in the armature circuit (, most of it in ; friction takes the rest). Plugging stops the shaft in under a second but dissipates three times the kinetic energy, because the supply keeps pushing current through the resistor. Regeneration returns energy instead of burning it, which is why electric trains and modern lifts use it.
Note the field-weakening line: with 80 % flux the motor needs for rated torque, more than its rating. In the constant-power region you get rated power, not rated torque.
Interactive: dynamic braking of a small motor
The small motor from DC Motors spins at (the capacitor CJ starts at IC=500) and is switched onto a braking resistor RBR. Now the back-EMF source drives current through the armature and the resistor, and GT draws the braking torque out of the speed node. With , the total gives a braking time constant : the lab shows at and at , with the current peaking near about after switching (the armature inductance delays it) and then falling.
Make RBR : the current is tiny and the motor almost coasts (the only friction here is RB). Make it : faster stopping, higher current. A short circuit () gives the fastest stop and the highest current, limited only by .
Guided lab: brake a small motor by shorting it
Hand calculation. For a small motor with , and rotor , braking into has ; coasting on bearing friction alone takes about a second or more.
Simulation. The netlist lab above with your , and .
What you would measure. Run the motor at from a current-limited supply, with a toggle switch that disconnects the supply and connects either nothing (coast) or a resistor (brake) across the motor. Watch the motor voltage on a scope (it is minus a small drop, so it is a speed signal): coasting decays over about a second, braking in tens of milliseconds, and an added flywheel (a small brass disc) stretches both in proportion to the inertia. Expect the braking time constant within of : brush resistance and friction are not constant.
Hazards and safe setup. Supply at most , current-limited; clamp the motor; a flywheel must be balanced and firmly fixed, with a guard over it; keep fingers, hair and sleeves away. Use a break-before-make switch so the supply is never shorted through the brake resistor. A coasting motor still generates: its terminals are live until it stops.
Pitfalls
- Weakening the field and expecting rated torque. Above base speed the torque at rated current falls as .
- Losing the field. A shunt motor whose field circuit opens can overspeed dangerously (flux to residual); drives have a field-loss trip.
- Plugging past zero. Without a zero-speed switch the motor accelerates the other way.
- Assuming regeneration is always possible. A diode rectifier cannot accept reverse power; the DC link voltage rises until something trips, so drives add a braking chopper and resistor.
Practice
- Find the speed of the worked-example motor at half rated torque with .
- What field fraction lets the motor reach at on ?
- A regenerating motor runs at on . Find the current returned.
Answer
- : .
- , i.e. of full flux.
- , less than : it is not regenerating yet; it motors with . Regeneration starts above the no-load speed, .
Test yourself
Above base speed a DC drive weakens the field. With the armature current held at rated, the available torque…
- stays at rated
- falls roughly as , keeping power constant
- rises
- falls as
Which braking method returns energy to the supply?
- dynamic braking
- plugging
- regenerative braking
- coasting
Why does plugging need a larger series resistance than dynamic braking for the same current?
- the field is weaker
- supply voltage and back-EMF add in the armature circuit
- the inertia is larger
- it does not
Armature-resistance speed control is inefficient because…
- it weakens the field
- the resistor dissipates , a large share of the input at low speed
- it raises the no-load speed
- it needs a converter