TExcelTAD
Home › Electrical Machines & Transformers › The Torque–Slip Curve: Starting and Maximum Torque

The Torque–Slip Curve: Starting and Maximum Torque

Will the motor start the loaded conveyor? Will it stall if the supply sags by 10 %? How much does the speed fall from no load to full load? All three questions are answered by one curve: the induced torque of an induction motor as a function of its slip (or speed). This lesson derives it from the equivalent circuit, finds its two famous points, the starting torque and the maximum (breakdown) torque, and shows how rotor resistance, supply voltage and rotor design reshape it.

Safety: the example motor is a 400 V400\ \text{V} three-phase machine; this lesson is calculation and simulation only.

The torque formula

The magnetising branch makes the full circuit awkward, so replace everything to the left of the rotor branch by its Thevenin equivalent (as in Thévenin and Norton):

Vth=V1 jXmR1+j(X1+Xm),Zth=Rth+jXth=jXm (R1+jX1)R1+j(X1+Xm)\mathbf{V}_{th} = \mathbf{V}_1\,\frac{jX_m}{R_1 + j(X_1 + X_m)}, \qquad Z_{th} = R_{th} + jX_{th} = \frac{jX_m\,(R_1 + jX_1)}{R_1 + j(X_1 + X_m)}

The rotor current is then I2′=Vth/∣Zth+R2′/s+jX2′∣I_2' = V_{th}/\lvert Z_{th} + R_2'/s + jX_2' \rvert, and T=Pag/ωsT = P_\text{ag}/\omega_s with Pag=3I2′2R2′/sP_\text{ag} = 3I_2'^2R_2'/s:

T(s)=3 Vth2 R2′/sωs[(Rth+R2′/s)2+(Xth+X2′)2]T(s) = \frac{3\,V_{th}^2\,R_2'/s}{\omega_s\left[(R_{th} + R_2'/s)^2 + (X_{th} + X_2')^2\right]}

Two limits explain the shape. At small slip R2′/sR_2'/s dominates the bracket and T≈3Vth2s/(ωsR2′)T \approx 3V_{th}^2 s/(\omega_s R_2'): torque is proportional to slip, so the speed falls only slightly with load (a "stiff" motor). At large slip the reactances dominate and T∝1/sT \propto 1/s.

Maximum torque

PagP_\text{ag} is the power delivered to the resistor R2′/sR_2'/s, so it peaks when that resistor matches the magnitude of the rest of the loop (Maximum Power Transfer):

sTmax⁡=R2′Rth2+(Xth+X2′)2,Tmax⁡=3Vth22ωs[Rth+Rth2+(Xth+X2′)2]s_{T\max} = \frac{R_2'}{\sqrt{R_{th}^2 + (X_{th} + X_2')^2}}, \qquad T_{\max} = \frac{3V_{th}^2}{2\omega_s\left[R_{th} + \sqrt{R_{th}^2 + (X_{th} + X_2')^2}\right]}

Three consequences an engineer uses every day:

  • Tmax⁡T_{\max} does not depend on R2′R_2'. Adding rotor resistance moves the peak to a higher slip without changing its height. A wound-rotor motor with R2′R_2' chosen so that sTmax⁡=1s_{T\max} = 1 starts with its maximum torque.
  • Tmax⁡∝V2T_{\max} \propto V^2. A 10 % voltage dip removes 19 % of the breakdown torque.
  • Tmax⁡T_{\max} is limited by the leakage reactances. Motors with low leakage have high breakdown torque but also high starting current.
T_start = 65 N m T_max = 162 N m, s = 0.185 rated 50 N m braking, s > 1 motoring, 0 < s < 1 generating, s < 0 n = 0n = n_s speedtorque

The curve continues beyond the motoring region. Driven backwards against the field (s>1s > 1, "plugging") the machine still produces torque in the field's direction, so it brakes, while drawing more than starting current. Driven above synchronous speed (s<0s < 0) R2′/sR_2'/s becomes negative, the torque reverses and the machine generates (Induction Generators); its peak there is larger, because the stator resistance now helps instead of hurts.

Worked example: the example motor's key points

Given: the example motor (V1=230.9 VV_1 = 230.9\ \text{V}, R1=0.55R_1 = 0.55, X1=1.0X_1 = 1.0, Xm=32X_m = 32, R2′=0.45R_2' = 0.45, X2′=1.4 ΩX_2' = 1.4\ \Omega), ωs=157.08 rad/s\omega_s = 157.08\ \text{rad/s}.

Find: the Thevenin values, sTmax⁡s_{T\max}, Tmax⁡T_{\max}, the starting torque and current, and the extra (referred) rotor resistance that would put Tmax⁡T_{\max} at standstill.

Solve:

Vth=230.9 V⋅32∣0.55+j33∣=223.9 V,Zth=0.517+j0.978 ΩsTmax⁡=0.45 Ω0.5172+2.3782 Ω=0.452.434=0.185(n=1223 rpm)Tmax⁡=3⋅223.92 V22⋅157.08 rad/s⋅(0.517+2.434) Ω=162.2 N mTstart=T(1)=3⋅223.92⋅0.45157.08[(0.967)2+2.3782] N m=65.4 N m\begin{aligned} V_{th} &= 230.9\ \text{V} \cdot \frac{32}{\lvert 0.55 + j33 \rvert} = 223.9\ \text{V}, \qquad Z_{th} = 0.517 + j0.978\ \Omega \\ s_{T\max} &= \frac{0.45\ \Omega}{\sqrt{0.517^2 + 2.378^2}\ \Omega} = \frac{0.45}{2.434} = 0.185 \quad (n = 1223\ \text{rpm}) \\ T_{\max} &= \frac{3 \cdot 223.9^2\ \text{V}^2}{2 \cdot 157.08\ \text{rad/s} \cdot (0.517 + 2.434)\ \Omega} = 162.2\ \text{N m} \\ T_\text{start} &= T(1) = \frac{3 \cdot 223.9^2 \cdot 0.45}{157.08\left[(0.967)^2 + 2.378^2\right]}\ \text{N m} = 65.4\ \text{N m} \end{aligned}

The starting current from the full circuit at s=1s = 1 is 91.0 A91.0\ \text{A}. For sTmax⁡=1s_{T\max} = 1 the rotor needs R2′=2.434 ΩR_2' = 2.434\ \Omega, so 1.984 Ω1.984\ \Omega (referred) must be added.

Check: relative to the rated values (48.9 N m48.9\ \text{N m} shaft, 14.4 A14.4\ \text{A}) this motor has Tmax⁡/TN=3.3T_{\max}/T_N = 3.3, Tstart/TN=1.3T_\text{start}/T_N = 1.3 and Istart/IN=6.3I_\text{start}/I_N = 6.3. Breakdown and current ratios are typical; the starting torque is low, because a plain single-cage model has constant R2′R_2'. Real cage rotors raise R2′R_2' at standstill (next section) and reach 2–2.5 times rated torque at start.

In Python: the curve and a fan load

python · try it yourself
import numpy as np
from scipy.optimize import brentq
V = 400 / np.sqrt(3); f, p = 50, 4
ns, ws = 120 * f / p, 4 * np.pi * f / p
R1, X1, Xm, R2, X2 = 0.55, 1.0, 32.0, 0.45, 1.4

# Thevenin equivalent of the supply seen by the rotor branch
Zth = (1j * Xm) * (R1 + 1j * X1) / (R1 + 1j * (X1 + Xm))
Vth = abs(V * 1j * Xm / (R1 + 1j * (X1 + Xm)))
Rth, Xth = Zth.real, Zth.imag

def torque(s, Vs=Vth):
    return 3 * Vs**2 * (R2 / s) / (ws * ((Rth + R2 / s)**2 + (Xth + X2)**2))

def current(s):
    Z2 = R2 / s + 1j * X2
    return abs(V / (R1 + 1j * X1 + 1j * Xm * Z2 / (1j * Xm + Z2)))

s_max = R2 / np.hypot(Rth, Xth + X2)
T_max = 3 * Vth**2 / (2 * ws * (Rth + np.hypot(Rth, Xth + X2)))
print(f"Vth = {Vth:.2f} V, Zth = {Rth:.4f} + j{Xth:.4f} ohm")
print(f"T_max = {T_max:.1f} N m at s = {s_max:.4f} ({ns*(1-s_max):.0f} rpm)")
print("   s      n (rpm)   T (N m)   I1 (A)")
for s in (0.01, 0.0255, 0.05, 0.1, s_max, 0.4, 0.7, 1.0):
    print(f"{s:7.4f}  {ns*(1-s):7.1f}  {torque(s):8.2f}  {current(s):7.2f}")

# fan torque (plus the motor's own rotational loss) ~ speed^2, equal to 50.35 N m at 1461.8 rpm
T_load = lambda n: 50.35 * (n / 1461.8)**2
for k in (1.0, 0.9):
    s_op = brentq(lambda s: torque(s, k * Vth) - T_load(ns * (1 - s)), 1e-4, s_max)
    print(f"V = {k*100:.0f} %: runs at {ns*(1-s_op):.1f} rpm, T = {torque(s_op, k*Vth):.2f} N m, "
          f"I1 = {k*current(s_op):.2f} A, T_start = {torque(1, k*Vth):.1f} N m, T_max = {k**2*T_max:.1f} N m")

import matplotlib.pyplot as plt
s = np.linspace(1e-3, 1, 500)
plt.plot(ns * (1 - s), torque(s), label="motor, 100 % V")
plt.plot(ns * (1 - s), torque(s, 0.9 * Vth), "--", label="motor, 90 % V")
plt.plot(ns * (1 - s), T_load(ns * (1 - s)), ":", label="fan load")
plt.xlabel("speed (rpm)"); plt.ylabel("torque (N m)"); plt.legend(); plt.grid(True)
plt.show()
Vth = 223.91 V, Zth = 0.5170 + j0.9783 ohm
T_max = 162.2 N m at s = 0.1849 (1223 rpm)
   s      n (rpm)   T (N m)   I1 (A)
 0.0100   1485.0     20.74     8.60
 0.0255   1461.8     50.35    14.43
 0.0500   1425.0     89.55    24.67
 0.1000   1350.0    139.78    42.47
 0.1849   1222.7    162.24    61.83
 0.4000    900.0    128.97    80.91
 0.7000    450.0     87.91    88.34
 1.0000      0.0     65.37    91.04
V = 100 %: runs at 1461.8 rpm, T = 50.35 N m, I1 = 14.43 A, T_start = 65.4 N m, T_max = 162.2 N m
V = 90 %: runs at 1452.3 rpm, T = 49.70 N m, I1 = 15.37 A, T_start = 52.9 N m, T_max = 131.4 N m

The fan settles where the two curves cross. At 90 % voltage the speed falls only 10 rpm10\ \text{rpm} and the current rises by about 6 % (the rotor needs more current to make nearly the same torque from less flux), but the starting and breakdown torques both fall by 19 %: voltage dips matter most for starting and for loads close to breakdown, not for a fan already running.

Rotor design: getting starting torque without losing efficiency

The conflict is plain from the formulas: high R2′R_2' gives high starting torque and lower starting current, low R2′R_2' gives small slip and high efficiency at full load. Cage rotors resolve it with the skin effect in the bars (Lossy Media). At standstill the rotor frequency is 50 Hz50\ \text{Hz} and current crowds into the top of a deep bar (or the outer bars of a double cage), so the effective R2′R_2' is high; at running slip the rotor frequency is 11–2 Hz2\ \text{Hz}, the current spreads over the whole bar and R2′R_2' is low.

NEMA MG 1 groups US cage motors by their torque–speed shape into design classes (described here from memory; check the current edition): Design A and B normal starting torque (B with limited locked-rotor current, the common general-purpose motor), Design C high starting torque from a double cage (loaded conveyors, compressors), Design D very high starting torque and high slip (5–8 %+, punch presses with flywheels). IEC 60034-12 uses designs N and H in a similar way. The test procedures in IEEE 112 split the measured leakage reactance between X1X_1 and X2′X_2' according to this class (No-Load and Blocked-Rotor Tests).

Interactive: the circuit at breakdown slip

In the netlist lab below RR is R2′/sR_2'/s, set to 2.434 Ω2.434\ \Omega, which is sTmax⁡s_{T\max}. The lab shows I2′=59.07 AI_2' = 59.07\ \text{A} (I(RR)), so T=3⋅59.072⋅2.434/157.08=162.2 N mT = 3 \cdot 59.07^2 \cdot 2.434/157.08 = 162.2\ \text{N m}, the maximum. Try 17.65 Ω17.65\ \Omega (rated) and 0.45 Ω0.45\ \Omega (start) and compute TT the same way.

050100150100m1101001k10kf (Hz)|V| (V)0 A50 A|I| (A)|V(c)||I(RR)|phasors at f = 50.00 Hz (magnitude @ phase)V(a)231 V @ 0.0 degV(b)207 V @ 6.3 degV(c)166 V @ -8.0 degV(d)144 V @ -37.9 degI(V1)61.8 A @ 137.9 degI(R1)61.8 A @ -42.1 degI(L1)61.8 A @ -42.1 degI(LM)5.18 A @ -98.0 degI(L2)59.1 A @ -37.9 degI(RR)59.1 A @ -37.9 deg

Guided lab (simulation and datasheet)

Hand calculation. Compute Tmax⁡T_{\max} and sTmax⁡s_{T\max} for your own motor parameters with the two formulas.

Simulation. Change R2 in the code to 2.4342.434 and confirm that the peak moves to standstill without changing height.

What you would measure. A torque–speed curve is recorded on a qualified test bed (not a learner experiment: 400 V400\ \text{V}, large starting currents and stored rotating energy) by accelerating the motor slowly against a controlled dynamometer, or by measuring acceleration of a known inertia (T−Tload=J dω/dtT - T_\text{load} = J\,d\omega/dt). The manufacturer's datasheet gives the three points: for a motor like this one expect locked-rotor torque about 2×2\times rated, breakdown about 3×3\times, locked-rotor current 6–7 times rated, with IEC 60034-1 tolerances of −15 %-15\ \%/+25 %+25\ \% on locked-rotor torque and −10 %-10\ \% on breakdown torque (from memory; check the current edition, 2026).

Pitfalls

  • Confusing induced and shaft torque. The formula gives the electromagnetic torque; friction and windage come off before the shaft.
  • Using the Thevenin voltage for the stator current. VthV_{th} only serves the rotor branch; compute I1I_1 from the full circuit.
  • Assuming a voltage dip slows the motor a lot. On the stable part of the curve speed changes little; the risk is stalling near breakdown or failing to start.
  • Running on the unstable side. Left of sTmax⁡s_{T\max} a load increase lowers torque and the motor stalls. Rated operation is always far right of the peak.

Practice

  1. With VV reduced to 80 %, what are Tmax⁡T_{\max} and TstartT_\text{start} of the example motor?
  2. A wound-rotor motor has sTmax⁡=0.2s_{T\max} = 0.2 with R2′=0.3 ΩR_2' = 0.3\ \Omega. What total rotor resistance (referred) gives maximum torque at start?
  3. Near no load, T≈3Vth2s/(ωsR2′)T \approx 3V_{th}^2 s/(\omega_s R_2'). Estimate the slip of the example motor at 25 N m25\ \text{N m} with it.
Answer
  1. Both scale with V2=0.64V^2 = 0.64: Tmax⁡=103.8 N mT_{\max} = 103.8\ \text{N m}, Tstart=41.8 N mT_\text{start} = 41.8\ \text{N m}.
  2. sTmax⁡∝R2′s_{T\max} \propto R_2', so R2′=0.3/0.2=1.5 ΩR_2' = 0.3/0.2 = 1.5\ \Omega (add 1.2 Ω1.2\ \Omega).
  3. s≈25⋅157.08⋅0.45/(3⋅223.92)=0.0118s \approx 25 \cdot 157.08 \cdot 0.45/(3 \cdot 223.9^2) = 0.0118 (the exact formula gives slightly more, about 0.01210.0121).

Test yourself

Doubling the rotor resistance of a wound-rotor induction motor…

  1. doubles the maximum torque
  2. halves the maximum torque
  3. doubles the slip at maximum torque, same maximum torque
  4. has no effect on the curve

The supply voltage falls by 10 %. The breakdown torque falls by about…

  1. 5 %
  2. 10 %
  3. 19 %
  4. 30 %

Why do deep-bar and double-cage rotors give more starting torque?

  1. they have fewer poles
  2. skin effect raises the rotor resistance at standstill (50 Hz rotor current) but not at running slip
  3. they reduce the magnetising current
  4. they increase the air gap

In which region does an induction machine run as a generator?

  1. s>1s > 1
  2. 0<s<10 < s < 1
  3. s=1s = 1
  4. s<0s < 0