TExcelTAD

Wind Turbines and Power Curves

A 4 MW4\ \text{MW} wind turbine is called "4 MW", but over a year it delivers on average perhaps 1.51.5 to 2 MW2\ \text{MW}, and at any moment anything from zero to its rating, depending on the wind. To plan a grid with wind farms an engineer needs three things: how power depends on wind speed (the power curve), how often each wind speed occurs (the wind distribution), and how the turbine's generator and converter behave electrically. This lesson builds all three from first principles and turns them into an annual energy estimate.

Safety: wind turbines are tall machines with large stored rotational energy and medium-voltage electrics; this lesson is calculation and simulation only. The bench analogue uses a small DC fan motor in front of a desk fan.

Power in the wind

Air of density ρ\rho moving at speed vv through an area AA carries kinetic energy at the rate 12m˙v2=12ρAv3\tfrac{1}{2}\dot{m}v^2 = \tfrac{1}{2}\rho A v^3. A rotor can only capture a fraction CpC_p of it, the power coefficient:

P=12 ρ A v3 Cp,Cp≤Cp,Betz=1627=0.593P = \tfrac{1}{2}\,\rho\,A\,v^3\,C_p, \qquad C_p \le C_{p,\text{Betz}} = \frac{16}{27} = 0.593

The Betz limit follows from momentum: a rotor that stopped the air completely would block the flow, one that let it through unslowed would extract nothing; the optimum slows the wind to one third of its upstream speed far behind the rotor. Large modern rotors reach Cp≈0.45C_p \approx 0.45 to 0.500.50 at their best operating point.

Three consequences dominate wind engineering:

  • The cube. Twice the wind speed gives eight times the power, so a site with 10 %10\ \% more mean wind gives roughly 2525 to 30 %30\ \% more energy. Turbines are put on hills, out at sea and on tall towers (wind speed grows with height).
  • The area. Power grows with the rotor diameter squared, which is why rotors have grown past 150 m150\ \text{m} onshore and to 200200 to 260 m260\ \text{m} offshore, with prototypes larger still (mid-2020s figures).
  • The tip-speed ratio λ=ωR/v\lambda = \omega R/v sets CpC_p. Each rotor has an optimum (often around 77 to 99), so in light winds the controller varies the rotor speed to stay at it.

The power curve

A real turbine follows four regions:

Region Wind speed (typical) What the control does
below cut-in <3 m/s< 3\ \text{m/s} parked or idling, no output
partial load 33 to about 11 m/s11\ \text{m/s} variable speed at optimum λ\lambda, CpC_p near its maximum: P∝v3P \propto v^3
full load rated to 25 m/s25\ \text{m/s} blades pitched to spill power, output held at rating
above cut-out >25 m/s> 25\ \text{m/s} shut down and feathered to protect the structure (many newer turbines ramp down gradually instead)

The numbers vary by model; the manufacturer publishes a measured power curve to IEC 61400-12-1 (power performance measurements; edition 3.0, 2022, current as of 2026).

Wind distribution and annual energy

Wind speeds at a site follow, approximately, a Weibull distribution; with shape parameter k=2k = 2 it is the Rayleigh distribution, fixed by the mean speed vˉ\bar{v} alone:

f(v)=πv2vˉ2exp⁡ ⁣(−π4(vvˉ)2),Pˉ=∫0∞P(v) f(v) dv,AEP=8760 h⋅Pˉf(v) = \frac{\pi v}{2\bar{v}^2}\exp\!\left(-\frac{\pi}{4}\left(\frac{v}{\bar{v}}\right)^2\right), \qquad \bar{P} = \int_0^\infty P(v)\,f(v)\,dv, \qquad \text{AEP} = 8760\ \text{h} \cdot \bar{P}

The capacity factor is Pˉ/Prated\bar{P}/P_\text{rated}. Onshore wind farms typically achieve about 2525 to 35 %35\ \% and offshore farms 4040 to 50 %50\ \% (2020s fleet averages; individual sites vary widely). Wake losses inside a farm, availability and electrical losses take a further 1010 to 15 %15\ \% off a single-turbine estimate.

Worked example: a 4 MW turbine

Given: rotor diameter 130 m130\ \text{m}, ρ=1.225 kg/m3\rho = 1.225\ \text{kg/m}^3, Cp=0.45C_p = 0.45 in partial load, rated power 4 MW4\ \text{MW}, cut-in 3 m/s3\ \text{m/s}, cut-out 25 m/s25\ \text{m/s}; a site with a Rayleigh distribution and mean wind 7.5 m/s7.5\ \text{m/s} at hub height.

Find: the power at 10 m/s10\ \text{m/s}, the rated wind speed, the mean power, the AEP and the capacity factor.

Solve:

A=π(130 m)24=13 273 m2P(10)=12⋅1.225 kgm3⋅13 273 m2⋅(10 ms)3⋅0.45=3.66 MWvrated=(4×106 W12⋅1.225⋅13 273⋅0.45)1/3=10.3 m/s\begin{aligned} A &= \frac{\pi (130\ \text{m})^2}{4} = 13\,273\ \text{m}^2 \\ P(10) &= \tfrac{1}{2} \cdot 1.225\ \tfrac{\text{kg}}{\text{m}^3} \cdot 13\,273\ \text{m}^2 \cdot (10\ \tfrac{\text{m}}{\text{s}})^3 \cdot 0.45 = 3.66\ \text{MW} \\ v_\text{rated} &= \left(\frac{4 \times 10^6\ \text{W}}{\tfrac{1}{2} \cdot 1.225 \cdot 13\,273 \cdot 0.45}\right)^{1/3} = 10.3\ \text{m/s} \end{aligned}

The mean power needs the integral, done numerically below: Pˉ=1.77 MW\bar{P} = 1.77\ \text{MW}, AEP=15.5 GWh\text{AEP} = 15.5\ \text{GWh}, CF=44 %\text{CF} = 44\ \%.

Check: the Betz limit would give 4.82 MW4.82\ \text{MW} at 10 m/s10\ \text{m/s}, so 3.66 MW3.66\ \text{MW} is 76 %76\ \% of the theoretical maximum, plausible. A capacity factor of 44 %44\ \% is high for onshore: this simple model holds CpC_p constant right up to rating and ignores wake and electrical losses, so treat it as an upper bound.

In Python: power curve, distribution and AEP

python · try it yourself
import numpy as np
import matplotlib.pyplot as plt

rho, D, Cp, Prated = 1.225, 130.0, 0.45, 4e6
A = np.pi * D**2 / 4
v_in, v_out = 3.0, 25.0

def power(v):
    p = np.minimum(0.5 * rho * A * v**3 * Cp, Prated)
    return np.where((v < v_in) | (v > v_out), 0.0, p)

def rayleigh(v, vmean):
    return np.pi * v / (2 * vmean**2) * np.exp(-np.pi / 4 * (v / vmean)**2)

v = np.linspace(0, 30, 3001)
print(f"A = {A:.0f} m2, P(10 m/s) = {float(power(np.array(10.0)))/1e6:.2f} MW,"
      f" Betz limit at 10 m/s = {0.5*rho*A*1000*16/27/1e6:.2f} MW")
print(f"rated wind speed = {(Prated / (0.5*rho*A*Cp))**(1/3):.1f} m/s")
for vm in (6.0, 7.5, 9.0):
    Pbar = np.trapezoid(power(v) * rayleigh(v, vm), v)
    print(f"mean wind {vm:.1f} m/s: mean power {Pbar/1e6:.2f} MW, AEP {Pbar*8760/1e9:5.1f} GWh, CF {100*Pbar/Prated:4.1f} %")

fig, ax = plt.subplots(figsize=(7, 3.5))
ax.plot(v, power(v) / 1e6, label="power curve (MW)")
ax.bar(np.arange(0.5, 30), [np.trapezoid(rayleigh(v[(v >= k) & (v <= k + 1)], 7.5), v[(v >= k) & (v <= k + 1)]) * 20 for k in range(30)],
       width=0.9, alpha=0.3, label="hours share x 20 (mean 7.5 m/s)")
ax.set_xlabel("wind speed (m/s)"); ax.set_ylabel("MW"); ax.legend(); ax.grid(alpha=0.3)
fig.tight_layout()
plt.show()
A = 13273 m2, P(10 m/s) = 3.66 MW, Betz limit at 10 m/s = 4.82 MW
rated wind speed = 10.3 m/s
mean wind 6.0 m/s: mean power 1.20 MW, AEP  10.5 GWh, CF 30.0 %
mean wind 7.5 m/s: mean power 1.77 MW, AEP  15.5 GWh, CF 44.3 %
mean wind 9.0 m/s: mean power 2.23 MW, AEP  19.5 GWh, CF 55.7 %

Raising the mean wind from 66 to 7.5 m/s7.5\ \text{m/s} (25 % more) adds 48 %48\ \% more energy; the power cap at rating keeps it from being the full cube.

The electrical side: four turbine types

Type Generator and converter Grid behaviour
1 squirrel-cage induction generator, direct on line, fixed speed absorbs reactive power, needs capacitors; speed fixed, so CpC_p is optimal at one wind speed only
2 wound-rotor induction generator with variable rotor resistance a few percent of speed range
3 doubly-fed induction generator (DFIG): stator on the grid, rotor fed by a converter rated about 30 %30\ \% variable speed (±30 %\pm 30\ \%), reactive control; common in the 2000s and 2010s
4 synchronous (often permanent-magnet) or induction generator behind a full-power converter any speed, full reactive control and fault ride-through; dominant in new large and offshore turbines

Types 3 and 4 connect through power electronics (Power Electronics & Motor Drives), so the grid does not see the rotor's kinetic energy as natural inertia, and they give only a limited fault current set by the converter rating. Grid codes therefore demand fault ride-through, reactive current during faults and, increasingly, synthetic inertia and grid-forming control (Smart Grid and DER, Frequency Control).

Guided lab: a desk-fan "wind turbine"

Hand calculation. A desk fan blows air at perhaps 3 m/s3\ \text{m/s} through the 0.01 m20.01\ \text{m}^2 of a small propeller: 12⋅1.2⋅0.01⋅27=0.16 W\tfrac{1}{2} \cdot 1.2 \cdot 0.01 \cdot 27 = 0.16\ \text{W} in the wind, and at Cp=0.2C_p = 0.2 (small rotors are poor) about 30 mW30\ \text{mW}.

Simulation. Change D, Cp, Prated, v_in and v_out in the program to the toy's values and plot its power curve.

What you would measure. A small DC motor with a propeller, loaded by a resistor (try 1010 to 100 Ω100\ \Omega), at several distances from the fan; an anemometer (or a phone app with an anemometer accessory) for wind speed; a DMM for voltage. Expect tens of milliwatts and a power that falls steeply with distance, roughly as the cube of the measured wind speed, with ±20 %\pm 20\ \% scatter from the turbulent fan flow. You will also find an optimum load resistance, the bench version of optimum tip-speed ratio.

Hazards and safe setup. Keep fingers clear of both propellers, use a fan with a guard, and keep the motor's output below 12 V12\ \text{V} (it is a few volts here).

Pitfalls

  • Mean wind cubed is not mean power. v3‾>vˉ3\overline{v^3} > \bar{v}^3 (by a factor of about 1.91.9 for a Rayleigh distribution), so use the distribution.
  • Rated power is not typical power. Plan energy with the capacity factor, and firm capacity with even less.
  • Hub height. Wind data measured at 10 m10\ \text{m} must be extrapolated to hub height (power law or log law), with large uncertainty.
  • Air density. It falls with altitude and temperature; a site at 1500 m1500\ \text{m} has about 15 %15\ \% less power at the same speed.

Practice

  1. What power is in a 12 m/s12\ \text{m/s} wind through a 150 m150\ \text{m} rotor (ρ=1.225\rho = 1.225), and what could the Betz limit capture?
  2. A 3 MW3\ \text{MW} turbine produces 7.9 GWh7.9\ \text{GWh} in a year. What is its capacity factor?
  3. Why do pitch-regulated turbines keep output flat above rated speed rather than letting it rise?
Answer
  1. A=17 671 m2A = 17\,671\ \text{m}^2; wind power 12⋅1.225⋅17 671⋅1728=18.7 MW\tfrac{1}{2} \cdot 1.225 \cdot 17\,671 \cdot 1728 = 18.7\ \text{MW}; Betz 0.593⋅18.7=11.1 MW0.593 \cdot 18.7 = 11.1\ \text{MW}.
  2. 7.9×109/(3×106⋅8760)=30.1 %7.9 \times 10^9/(3 \times 10^6 \cdot 8760) = 30.1\ \%.
  3. The generator, converter, gearbox and structure would otherwise have to be sized for winds that occur only a few hours a year; capping at rating gives the most energy per unit cost.

Test yourself

If the wind speed doubles (below rated), the power of a turbine…

  1. doubles
  2. quadruples
  3. rises 8 times
  4. stays the same

The Betz limit on the power coefficient is…

  1. 0.25
  2. 0.5
  3. 16/27, about 0.593
  4. 1

Which turbine type connects its generator to the grid only through a full-power converter?

  1. Type 1
  2. Type 2
  3. Type 3 (DFIG)
  4. Type 4

A 4 MW turbine has a mean output of 1.6 MW. Its capacity factor and annual energy are…

  1. 40 % and 14.0 GWh
  2. 40 % and 35 GWh
  3. 25 % and 14.0 GWh
  4. 60 % and 21 GWh